The evidence for cerebral protection: An analysis and summary of the literature

被引:15
作者
Macdonald, Sumaira [1 ]
机构
[1] Freeman Rd Hosp, Newcastle Upon Tyne NE7 7DN, Tyne & Wear, England
关键词
emboli; cerebral protection; evidence;
D O I
10.1016/j.ejrad.2006.05.027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
It has been considered likely that the majority of cerebral ischaemic episodes following carotid artery stenting are due to cerebral embolisation. It is intuitive therefore, to attempt to prevent these presumptive emboli, whether they are comprised of air or formed elements, from reaching the brain. Various pharmacological and mechanical solutions are being used. The available literature is hampered by comparisons against historical controls of unprotected CAS with many confounding variables that may influence outcome. There is no clinical Level-I evidence to support the use of protection devices but Level-III and Level-IV evidence suggest benefit. (C) 2006 Published by Elsevier Ireland Ltd.
引用
收藏
页码:20 / 25
页数:6
相关论文
共 32 条
[1]  
Adami CA, 2002, J ENDOVASC THER, V9, P147, DOI 10.1583/1545-1550(2002)009<0147:UOTPAE>2.0.CO
[2]  
2
[3]   Effect of the distal-balloon protection system on microembolization during carotid stenting [J].
Al-Mubarak, N ;
Roubin, GS ;
Vitek, JJ ;
Iyer, SS ;
New, G ;
Leon, MB .
CIRCULATION, 2001, 104 (17) :1999-2002
[4]   Carotid plaque echolucency increases the risk of stroke in carotid stenting - The Imaging in Carotid Angioplasty and Risk of Stroke (ICAROS) study [J].
Biasi, GM ;
Froio, A ;
Diethrich, EB ;
Deleo, G ;
Galimberti, S ;
Mingazzini, P ;
Nicolaides, AN ;
Griffin, M ;
Raithel, D ;
Reid, DB ;
Valsecchi, MG .
CIRCULATION, 2004, 110 (06) :756-762
[5]   Procedure-related complications and early neurological adverse events of unprotected and protected carotid stenting: Temporal trends in a consecutive-patient series [J].
Boltuch, J ;
Sabeti, S ;
Amighi, J ;
Dick, P ;
Mlekusch, W ;
Schlager, O ;
Ahmadi, A ;
Minar, E ;
Schillinger, M .
JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (05) :538-547
[6]  
Brown MM, 2001, LANCET, V357, P1729
[7]  
Coggia M, 2000, J VASC SURG, V31, P550
[8]   Comparison of hemodynamic cerebral ischemia and microembolic signals detected during carotid endarterectomy and carotid angioplasty [J].
Crawley, F ;
Clifton, A ;
Buckenham, T ;
Loosemore, T ;
Taylor, RS ;
Brown, MM .
STROKE, 1997, 28 (12) :2460-2464
[9]  
Crawley F, 2004, COCHRANE DB SYST REV, DOI [10.1002/14651858.CD000515.pub2, DOI 10.1002/14651858.CD000515.PUB2]
[10]   Clinical results of cerebral protection with a filter device during stent implantation of the carotid artery [J].
Jaeger, H ;
Mathias, K ;
Drescher, R ;
Hauth, E ;
Bockisch, G ;
Demirel, E ;
Gissler, HM .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 24 (04) :249-256