摘要
Cooling towers are used to cool a warm water stream through evaporation of part of the water into an air stream. A cooling tower consists of three zones; namely spray, packing and rain zones. In cooling towers, a significant portion of the total heat rejected may occur in the spray and rain zones. These zones are modeled and solved numerically using a computer code. The developed models of these zones are validated against experimental data. For the case study under consideration, the error in calculation of the tower volume is 1.5% when the spray and rain zones are neglected. This error is reduced to 1.1% and 0.25% as the spray and rain zones are incorporated in the model, respectively. Furthermore, the effect of the Lewis factor on the performance prediction of wet-cooling towers is investigated using Bosnjakovic equation. (C) 2008 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:996 / 1002
页数:7
相关论文
共 19 条
[1]  
Bosnjakovic F., 1965, Technische Thermodinamik
[2]   Analysis of heat, mass, and momentum transfer in the rain zone of counterflow cooling towers [J].
de Villiers, E ;
Kröger, DG .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1999, 121 (04) :751-755
[3]   Modelling of cooling tower splash pack [J].
Dreyer, AA ;
Erens, PJ .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1996, 39 (01) :109-123
[4]   Evaporative cooling of water in a mechanical draft cooling tower [J].
Fisenko, SP ;
Brin, AA ;
Petruchik, AI .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (01) :165-177
[5]   Evaporative cooling of water in a natural draft cooling tower [J].
Fisenko, SP ;
Petruchik, AI ;
Solodukhin, AD .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (23) :4683-4694
[6]   A simplified modeling of mechanical cooling tower for control and optimization of HVAC systems [J].
Jin, Guang-Yu ;
Cai, Wen-Jian ;
Lu, Lu ;
Lee, Eng Lock ;
Chiang, Andrew .
ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (02) :355-365
[7]  
KARAMI M, 2008, 16 INT C IR IN PRESS
[8]   A comprehensive design and performance evaluation study of counter flow wet cooling towers [J].
Khan, JUR ;
Qureshi, BA ;
Zubair, SM .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (08) :914-923
[9]   Performance characteristics of counter flow wet cooling towers [J].
Khan, JUR ;
Yaqub, M ;
Zubair, SM .
ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (13) :2073-2091
[10]   The Lewis factor and its influence on the performance prediction of wet-cooling towers [J].
Kloppers, JC ;
Kröger, DG .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2005, 44 (09) :879-884