Ultrasonographic measurement of tongue movement during swallowing

被引:5
作者
Peng, CL
Jost-Brinkmann, PG
Miethke, RR
Lin, CT
机构
[1] Taipei Med Coll, Sch Dent, Dept Prosthodont, Taipei 110, Taiwan
[2] Taipei Med Coll, Sch Dent, Dept Orthodont, Taipei, Taiwan
[3] Humboldt Univ, Univ Hosp Charite, Dept Orthodont & Dentofacial Orthoped, Berlin, Germany
关键词
ultrasonography; tongue; function; swallowing; Cushion-scanning technique;
D O I
10.7863/jum.2000.19.1.15
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Previous ultrasonographic studies on tongue functions were limited by the possibility of artifacts caused by movement of the submental area during function. Consequently, tongue movements were misinterpreted. A dynamic tongue imaging technique, the cushion-scanning technique, was used to overcome this problem. Later, swallowing was investigated and divided into five phases using cushion-scanning technique-aided M-mode ultrasonograms. In this study, cushion-scanning technique in combination with the B-mode and M-mode ultrasonography was applied to investigate and measure the tongue movement during swallowing in 55 normal persons. The average duration, range of motion and speed of swallowing were found to be 2.43 s, 24.06 mm, and 10.34 mm/s, respectively. The computer-aided B-mode plus M-mode ultrasonography in combination with the cushion-scanning technique is a valuable tool for study of tongue functions.
引用
收藏
页码:15 / 20
页数:6
相关论文
共 19 条
  • [1] DEGLUTITION - A STUDY OF FORM AND FUNCTION
    CLEALL, JF
    [J]. AMERICAN JOURNAL OF ORTHODONTICS, 1965, 51 (08): : 566 - &
  • [2] EKBERG O, 1986, Acta Radiologica Diagnosis, V27, P533
  • [3] FINDLAY IAN A., 1960, JOUR DENTAL RES, V39, P629, DOI 10.1177/00220345600390032401
  • [4] Fuhrmann R, 1993, Fortschr Kieferorthop, V54, P17, DOI 10.1007/BF02168015
  • [5] HIRAI T, 1989, J JPN PROSTHODONT SO, V33, P457
  • [6] CHARACTERIZATION OF TONGUE SHAPE
    MORRISH, KA
    STONE, M
    SONIES, BC
    KURTZ, D
    SHAWKER, T
    [J]. ULTRASONIC IMAGING, 1984, 6 (01) : 37 - 47
  • [7] Peng C L, 1994, Fortschr Kieferorthop, V55, P209, DOI 10.1007/BF02173752
  • [8] PENG CL, 1995, RADIOLOGE, V35, P747
  • [9] The cushion scanning technique: A method of dynamic tongue sonography and its comparison with the transducer-skin coupling scanning technique during swallowing
    Peng, CL
    JostBrinkmann, PG
    Miethke, RR
    [J]. ACADEMIC RADIOLOGY, 1996, 3 (03) : 239 - 244
  • [10] RAKOSI T, 1970, Fortschritte der Kieferorthopaedie, V31, P81, DOI 10.1007/BF02024853