The impact of floor thermal capacity on air temperature and energy consumption in buildings in temperate climate

被引:18
作者
Staszczuk, A. [1 ]
Kuczynski, T. [1 ]
机构
[1] Univ Zielona Cora, Fac Civil Engn Architecture & Environm Engn, Prof Z Szafrana 1 St, PL-65516 Zielona Gora, Poland
关键词
Thermal mass; Ground floor capacity; Heat storage; Heat waves; Energy consumption; RESIDENTIAL BUILDINGS; OVERHEATING RISK; INERTIA; MASS; PERFORMANCE; INSULATION; DWELLINGS; ENVELOPE; OPTIMIZATION; EFFICIENCY;
D O I
10.1016/j.energy.2019.05.202
中图分类号
O414.1 [热力学];
学科分类号
摘要
The paper analyses the efficiency of increasing the thermal mass above the floor to reduce summer overheating in one-storey residential terraced buildings in temperate climate. The effect of floor slab thickness on total yearly energy demand is also investigated. According to EN ISO 13786:2017 standard, the useful thermal mass thickness of building envelope is limited to approximately 8-10 cm distance from its surface. Increasing the floor slab thickness from 8 to 18 cm lowered the average and maximum indoor air temperature during 9 day heat wave by 1.25 K and 1.52 K, respectively. Since these effects were obtained for a room with a relatively high total thermal capacity, it can be expected that it would be higher for rooms with a low thermal capacity enclosure. Cooling, heating and total energy demand decreased by 27.1%, 7.5% and 17.0%, respectively. The experiment results show that increase of floor slab thickness over the maximum values given in EN ISO 13786:2017 standard can lead to significant decrease of indoor air temperature during summer heat wave as well as heating and cooling energy demand. The cooling effect remained stable both during the 24-h cycle and throughout the entire heat wave period. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:908 / 915
页数:8
相关论文
共 52 条
[1]  
[Anonymous], 2018, IPCC SR15
[2]  
[Anonymous], 2008, 6946 EN ISO
[3]  
[Anonymous], 2001, BRANZ
[4]  
[Anonymous], 2017, 13786 EN ISO
[5]   Thermal inertia and energy efficiency - Parametric simulation assessment on a calibrated case study [J].
Aste, Niccolo ;
Leonforte, Fabrizio ;
Manfren, Massimiliano ;
Mazzon, Manlio .
APPLIED ENERGY, 2015, 145 :111-123
[6]   High ambient temperature and mortality: a review of epidemiologic studies from 2001 to 2008 [J].
Basu, Rupa .
ENVIRONMENTAL HEALTH, 2009, 8
[7]  
Bellamy LA, 2000, J CEMENT CONCRETE AS
[8]   Influence of thermal insulation position in building envelope on the space cooling of high-rise residential buildings in Hong Kong [J].
Bojic, M ;
Yik, F ;
Sat, P .
ENERGY AND BUILDINGS, 2001, 33 (06) :569-581
[9]   Life cycle efficiency ratio: A new performance indicator for a life cycle driven approach to evaluate the potential of ventilative cooling and thermal inertia [J].
Brambilla, Arianna ;
Bonvin, Jerome ;
Flourentzou, Flourentzos ;
Jusselme, Thomas .
ENERGY AND BUILDINGS, 2018, 163 :22-33
[10]   A public health needs assessment for domestic indoor overheating [J].
Bundle, N. ;
O'Connell, E. ;
O'Connor, N. ;
Bone, A. .
PUBLIC HEALTH, 2018, 161 :147-153