Accurate calibration of a stereo-vision system in image-guided radiotherapy

被引:9
作者
Liu, Dezhi [1 ]
Li, Shidong [1 ]
机构
[1] Henry Ford Hlth Syst, Dept Radiat Oncol, Detroit, MI 48202 USA
关键词
radiotherapy; patient positioning; stereo-vision; calibration;
D O I
10.1118/1.2362873
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Image-guided radiotherapy using a three-dimensional (3D) camera as the on-board surface imaging system requires precise and accurate registration of the 3D surface images in the treatment machine coordinate system. Two simple calibration methods, an analytical solution as three-point matching and a least-squares estimation method as multipoint registration, were introduced to correlate the stereo-vision surface imaging frame with the machine coordinate system. Both types of calibrations utilized 3D surface images of a calibration template placed on the top of the treatment couch. Image transformational parameters were derived from corresponding 3D marked points on the surface images to their given coordinates in the treatment room coordinate system. Our experimental results demonstrated that both methods had provided the desired calibration accuracy of 0.5 mm. The multipoint registration method is more robust particularly for noisy 3D surface images. Both calibration methods have been used as our weekly QA tools for a 3D image-guided radiotherapy system. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:4379 / 4383
页数:5
相关论文
共 50 条
  • [41] A method of line structured light vision system calibration based on stereo vision
    Liu, Yubao
    Liu, Bin
    Lin, Junyi
    ADVANCED DESIGN AND MANUFACTURING TECHNOLOGY III, PTS 1-4, 2013, 397-400 : 1453 - 1458
  • [42] Research on Calibration Method of The Panoramic Stereo Sphere Vision System
    Zhu, Junchao
    Li, Yongchen
    Liu, Chang
    Ma, Zhijun
    Zhang, Baofeng
    2015 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2015, : 2346 - 2351
  • [43] Improvement of viewing experience on stereoscopic image guided by human stereo vision
    Jiawei Xu
    Seop Hyeong Park
    Xiaoqin Zhang
    Multimedia Tools and Applications, 2020, 79 : 4377 - 4394
  • [44] A Realtime Stereo Vision System Design using Disparity Calibration
    Suh G.-D.
    Lim J.-B.
    Jeong S.-H.
    Park T.-G.
    Transactions of the Korean Institute of Electrical Engineers, 2023, 72 (07) : 855 - 862
  • [45] Camera Calibration of Thermal-Infrared Stereo Vision System
    Zhang Yu
    Shen Lincheng
    Zhou Dianle
    Zhang Daibing
    Yan Chengping
    2013 FOURTH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS DESIGN AND ENGINEERING APPLICATIONS, 2013, : 197 - 201
  • [46] Improvement of viewing experience on stereoscopic image guided by human stereo vision
    Xu, Jiawei
    Park, Seop Hyeong
    Zhang, Xiaoqin
    MULTIMEDIA TOOLS AND APPLICATIONS, 2020, 79 (7-8) : 4377 - 4394
  • [47] Post-Prostatectomy image-Guided Radiotherapy: The invisible Target Concept
    Vilotte, Florent
    Antoine, Mickael
    Bobin, Maxime
    Latorzeff, Igor
    Supiot, Stephane
    Richaud, Pierre
    Thomas, Laurence
    Leduc, Nicolas
    Guerif, Stephane
    Iriondo-Alberdi, Jone
    de Crevoisier, Renaud
    Sargos, Paul
    FRONTIERS IN ONCOLOGY, 2017, 7
  • [48] A Non-invasive Weapon: Image-guided Radiotherapy for Hepatocellular Carcinoma
    Law, A. L. Y.
    Ng, W. T.
    Ka, S. Y. J.
    Yeung, R. M. W.
    HONG KONG JOURNAL OF RADIOLOGY, 2012, 15 (04): : S29 - S32
  • [49] Impact of positron emission tomography with computed tomography for image-guided radiotherapy
    Isnardi, V.
    Thureau, S.
    Vera, P.
    CANCER RADIOTHERAPIE, 2020, 24 (05): : 362 - 367
  • [50] Establishment of image-guided radiotherapy of orthotopic hepatocellular carcinoma mouse model
    Zhou, Kaixiao
    Jiang, Yabo
    Feng, Shuang
    Mo, Wei
    Nie, Jing
    Cao, Jianping
    Jiao, Yang
    ANIMAL MODELS AND EXPERIMENTAL MEDICINE, 2023, 6 (05) : 419 - 426