Accurate calibration of a stereo-vision system in image-guided radiotherapy

被引:9
作者
Liu, Dezhi [1 ]
Li, Shidong [1 ]
机构
[1] Henry Ford Hlth Syst, Dept Radiat Oncol, Detroit, MI 48202 USA
关键词
radiotherapy; patient positioning; stereo-vision; calibration;
D O I
10.1118/1.2362873
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Image-guided radiotherapy using a three-dimensional (3D) camera as the on-board surface imaging system requires precise and accurate registration of the 3D surface images in the treatment machine coordinate system. Two simple calibration methods, an analytical solution as three-point matching and a least-squares estimation method as multipoint registration, were introduced to correlate the stereo-vision surface imaging frame with the machine coordinate system. Both types of calibrations utilized 3D surface images of a calibration template placed on the top of the treatment couch. Image transformational parameters were derived from corresponding 3D marked points on the surface images to their given coordinates in the treatment room coordinate system. Our experimental results demonstrated that both methods had provided the desired calibration accuracy of 0.5 mm. The multipoint registration method is more robust particularly for noisy 3D surface images. Both calibration methods have been used as our weekly QA tools for a 3D image-guided radiotherapy system. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:4379 / 4383
页数:5
相关论文
共 50 条
  • [31] A Stereo-Vision System for Measuring the Ram Speed of Steam Hammers in an Environment with a Large Field of View and Strong Vibrations
    Chen, Ran
    Li, Zhongwei
    Zhong, Kai
    Liu, Xingjian
    Wu, Yonghui
    Wang, Congjun
    Shi, Yusheng
    SENSORS, 2019, 19 (05)
  • [32] The Comparison of Calibration Method of Binocular Stereo Vision System
    Zhang, Ke
    Gao, Zhao
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON MATERIAL, MECHANICAL AND MANUFACTURING ENGINEERING, 2015, 27 : 896 - 901
  • [33] Forward Control of Robotic Arm Using the Information from Stereo-vision Tracking System
    Puheim, Michal
    Bundzel, Marek
    Madarasz, Ladislav
    14TH IEEE INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE AND INFORMATICS (CINTI), 2013, : 57 - 62
  • [34] The initial study of LLS-based binocular stereo-vision system on underwater 3D image reconstruction in the laboratory
    Lin, Yu-Hsien
    Shou, Kuan-Po
    Huang, Lin-Jin
    JOURNAL OF MARINE SCIENCE AND TECHNOLOGY, 2017, 22 (03) : 513 - 532
  • [35] Advances in Image-Guided Radiotherapy in the Treatment of Oral Cavity Cancer
    Nien, Hsin-Hua
    Wang, Li-Ying
    Liao, Li-Jen
    Lin, Ping-Yi
    Wu, Chia-Yun
    Shueng, Pei-Wei
    Chung, Chen-Shuan
    Lo, Wu-Chia
    Lin, Shih-Chiang
    Hsieh, Chen-Hsi
    CANCERS, 2022, 14 (19)
  • [36] The use of fiducial markers in image-guided radiotherapy for gastric cancer
    Sia, Joseph
    Glance, Simon
    Chandran, Sujievvan
    Vaughan, Rhys
    Hamilton, Chris
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (05) : 626 - 628
  • [37] Investigation the Efficacy of Fuzzy Logic Implementation at Image-Guided Radiotherapy
    Torshabi, Ahmad Esmaili
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2022, 12 (02): : 163 - 170
  • [38] National survey on image-guided radiotherapy practice in New Zealand
    Padayachee, Jerusha
    Loh, Jasmin
    Tiong, Albert
    Lao, Louis
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2018, 62 (02) : 262 - 269
  • [39] Robust stereo vision and calibration methodology for accurate three-dimensional digital image correlation measurements on submerged objects
    Ke, X.
    Sutton, M. A.
    Lessner, S. M.
    Yost, M.
    JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 2008, 43 (08) : 689 - 704
  • [40] Development of a High-Precision, Image-Guided Radiotherapy, Multi-Purpose Radiation Isocenter Quality-Assurance Calibration and Checking System
    Liu, C.
    Yan, G.
    Helmig, R.
    Lebron, S.
    Kahler, D.
    MEDICAL PHYSICS, 2014, 41 (06) : 165 - 166