Accurate calibration of a stereo-vision system in image-guided radiotherapy

被引:9
|
作者
Liu, Dezhi [1 ]
Li, Shidong [1 ]
机构
[1] Henry Ford Hlth Syst, Dept Radiat Oncol, Detroit, MI 48202 USA
关键词
radiotherapy; patient positioning; stereo-vision; calibration;
D O I
10.1118/1.2362873
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Image-guided radiotherapy using a three-dimensional (3D) camera as the on-board surface imaging system requires precise and accurate registration of the 3D surface images in the treatment machine coordinate system. Two simple calibration methods, an analytical solution as three-point matching and a least-squares estimation method as multipoint registration, were introduced to correlate the stereo-vision surface imaging frame with the machine coordinate system. Both types of calibrations utilized 3D surface images of a calibration template placed on the top of the treatment couch. Image transformational parameters were derived from corresponding 3D marked points on the surface images to their given coordinates in the treatment room coordinate system. Our experimental results demonstrated that both methods had provided the desired calibration accuracy of 0.5 mm. The multipoint registration method is more robust particularly for noisy 3D surface images. Both calibration methods have been used as our weekly QA tools for a 3D image-guided radiotherapy system. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:4379 / 4383
页数:5
相关论文
共 50 条
  • [1] Novel method of calibration with restrictive constraints for stereo-vision system
    Cui, Jiashan
    Huo, Ju
    Yang, Ming
    JOURNAL OF MODERN OPTICS, 2016, 63 (09) : 835 - 846
  • [2] A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup
    Bert, C
    Metheany, KG
    Doppke, K
    Chen, GTY
    MEDICAL PHYSICS, 2005, 32 (09) : 2753 - 2762
  • [3] A novel registration method for image-guided neurosurgery system based on stereo vision
    An, Yong
    Wang, Manning
    Song, Zhijian
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S967 - S973
  • [4] A fast and accurate method of ultrasound probe calibration for image-guided surgery
    Welch, JN
    Bax, M
    Mori, K
    Krummel, T
    Shahidi, R
    Maurer, CR
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 1078 - 1078
  • [5] A stereo-vision system to automate the manufacture of a semitrailer chassis
    Samper, David
    Santolaria, Jorge
    Javier Brosed, Francisco
    Jose Aguilar, Juan
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2013, 67 (9-12) : 2283 - 2292
  • [6] Catadioptric stereo-vision system using a spherical mirror
    Barone, S.
    Neri, P.
    Paoli, A.
    Razionale, A. V.
    AIAS2017 - 46TH CONFERENCE ON STRESS ANALYSIS AND MECHANICAL ENGINEERING DESIGN, 2018, 8 : 83 - 91
  • [7] A stereo-vision system to automate the manufacture of a semitrailer chassis
    David Samper
    Jorge Santolaria
    Francisco Javier Brosed
    Juan José Aguilar
    The International Journal of Advanced Manufacturing Technology, 2013, 67 : 2283 - 2292
  • [8] Online calibration for a stereo vision measurement system
    Yu, ZJ
    Ma, SY
    Che, RS
    Wang, QZ
    Tian, W
    Li, ZH
    Li, JZ
    MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS VI, 2005, 295-296 : 723 - 728
  • [9] Vision based Object Follower Automated Guided Vehicle using Compressive Tracking and Stereo-vision
    Verma, Nishchal K.
    Nama, Pranay
    Kumar, Gaurav
    Siddhant, Aditya
    Ocean
    Raj, Akhilesh
    Dhar, Narendra Kumar
    Salour, Al
    2015 IEEE BOMBAY SECTION SYMPOSIUM (IBSS), 2015,
  • [10] Study of the Error Caused by Camera Movement for the Stereo-Vision System
    Liu, Yan
    Ge, Zhendong
    Yuan, Yingtao
    Su, Xin
    Guo, Xiang
    Suo, Tao
    Yu, Qifeng
    APPLIED SCIENCES-BASEL, 2021, 11 (20):