FLC polymerization: Another hurdle towards standardization of FLC measurements

被引:7
作者
Kaplan, Batia [1 ]
Jacobs, Joannes F. M. [2 ]
机构
[1] Sheba Med Ctr, Heller Inst Med Res, Ramat Gan, Israel
[2] Radboud Univ Nijmegen, Med Ctr, Dept Lab Med, Lab Med Immunol, Route 469,Geert Grootepl 10, NL-6525 GA Nijmegen, Netherlands
关键词
Free light chain; M-protein; Monoclonal gammopathy; Standardization;
D O I
10.1016/j.cca.2020.12.030
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
In the November issue of this journal, Caponi et al. convincingly show that free light chain (FLC) lambda measurements are influenced by the FLC-polymerization status. With liquid chromatography using a size-exclusion column they separated monoclonal FLC dimers from monomers. FLC analysis of these different fractions clearly indicated that Freelite (The Binding Site) reacted better with FLC dimers than with FLC monomers. In contrast, N Latex FLC (Siemens) recognizes mainly FLC monomers and has poor reactivity with the FLC dimers. This important finding may be one of the leading factors to explain discrepancies in FLC-quantification using Freelite versus other immunochemical assays such as N-Latex FLC.
引用
收藏
页码:42 / 43
页数:2
相关论文
共 9 条
[1]   Free light chain UV quantification compared with immunochemical measurement: How dimers and monomers may influence the results [J].
Caponi, Laura ;
Koni, Elona ;
Romiti, Nadia ;
Paolicchi, Aldo ;
Franzini, Maria .
CLINICA CHIMICA ACTA, 2020, 510 :278-284
[2]   Method comparison of four clinically available assays for serum free light chain analysis [J].
Fleming, Cherina K. A. ;
Swarttouw, Tim ;
Angelino, Corrie M. de Kat ;
Jacobs, Joannes F. M. ;
Russcher, Henk .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (01) :85-94
[3]   The use of serum free light chain dimerization patterns assist in the diagnosis of AL amyloidosis [J].
Gatt, Moshe E. ;
Kaplan, Batia ;
Yogev, Dean ;
Slyusarevsky, Elana ;
Pogrebijski, Galina ;
Golderman, Sizilia ;
Kukuy, Olga ;
Livneh, Avi .
BRITISH JOURNAL OF HAEMATOLOGY, 2018, 182 (01) :86-92
[4]   Is accuracy of serum free light chain measurement achievable? [J].
Jacobs, Joannes F. M. ;
Tate, Jillian R. ;
Merlini, Giampaolo .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (06) :1021-1030
[5]   N Latex FLC serum free light-chain assays in patients with renal impairment [J].
Jacobs, Joannes F. M. ;
Hoedemakers, Rein M. J. ;
Teunissen, Elisa ;
te Velthuis, Henk .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (06) :853-859
[6]   Immunoglobulin-free light chain monomer-dimer patterns help to distinguish malignant from premalignant monoclonal gammopathies: A pilot study [J].
Kaplan, Batia ;
Golderman, Sizilia ;
Aizenbud, Boris ;
Esev, Konstantin ;
Kukuy, Olga ;
Leiba, Merav ;
Livneh, Avi ;
Ben-Zvi, Ilan .
AMERICAN JOURNAL OF HEMATOLOGY, 2014, 89 (09) :882-888
[7]   Free light chains in plasma of patients with light chain amyloidosis and non-amyloid light chain deposition disease. High proportion and heterogeneity of disulfide-linked monoclonal free light chains as pathogenic features of amyloid disease [J].
Kaplan, Batia ;
Ramirez-Alvarado, Marina ;
Sikkink, Laura ;
Golderman, Sicilia ;
Dispenzieri, Angela ;
Livneh, Avi ;
Gallo, Gloria .
BRITISH JOURNAL OF HAEMATOLOGY, 2009, 144 (05) :705-715
[8]  
Kukuy O., 2019, CLIN EXP NEPHROL, V192, P7
[9]   Reference ranges of the Sebia free light chain ratio in patients with chronic kidney disease [J].
Lutteri, Laurence ;
Jacobs, Joannes F. M. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (09) :E232-E234