Potentially Pathogenic Bacteria in Shower Water and Air of a Stem Cell Transplant Unit

被引:53
作者
Perkins, Sarah D. [2 ]
Mayfield, Jennie [3 ]
Fraser, Victoria [4 ]
Angenent, Largus T. [1 ]
机构
[1] Cornell Univ, Dept Biol & Environm Engn, Ithaca, NY 14853 USA
[2] Washington Univ, Dept Energy Environm & Chem Engn, St Louis, MO 63130 USA
[3] Barnes Jewish Hosp, Hosp Epidemiol & Infect Prevent, St Louis, MO 63108 USA
[4] Washington Univ, Sch Med, Div Infect Dis, St Louis, MO 63108 USA
基金
美国国家科学基金会;
关键词
IN-HOSPITAL WATER; DRINKING-WATER; LEGIONELLA-PNEUMOPHILA; DISTRIBUTION-SYSTEMS; NONTUBERCULOUS MYCOBACTERIA; PSEUDOMONAS-AERUGINOSA; LEGIONNAIRES-DISEASE; AIRBORNE BACTERIAL; MOLECULAR METHODS; BACILLUS-CEREUS;
D O I
10.1128/AEM.00658-09
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Potential pathogens from shower water and aerosolized shower mist (i.e., shower aerosol) have been suggested as an environmental source of infection for immunocompromised patients. To quantify the microbial load in shower water and aerosol samples, we used culture, microscopic, and quantitative PCR methods to investigate four shower stalls in a stem cell transplant unit at Barnes-Jewish Hospital in St. Louis, MO. We also tested membrane-integrated showerheads as a possible mitigation strategy. In addition to quantification, a 16S rRNA gene sequencing survey was used to characterize the abundant bacterial populations within shower water and aerosols. The average total bacterial counts were 2.2 x 10(7) cells/liter in shower water and 3.4 x 104 cells/m(3) in shower aerosol, and these counts were reduced to 6.3 x 10(4) cells/liter (99.6% efficiency) and 8.9 x 10(3) cells/m(3) (82.4% efficiency), respectively, after membrane-integrated showerheads were installed. Potentially pathogenic organisms were found in both water and aerosol samples from the conventional showers. Most notable was the presence of Mycobacterium mucogenicum (99.5% identity) in the water and Pseudomonas aeruginosa (99.3% identity) in the aerosol samples. Membrane-integrated showerheads may protect immunocompromised patients from waterborne infections in a stem cell transplant unit because of efficient capture of vast numbers of potentially pathogenic bacteria from hospital water. However, an in-depth epidemiological study is necessary to investigate whether membrane-integrated showerheads reduce hospital-acquired infections. The microbial load in shower aerosols with conventional showerheads was elevated compared to the load in HEPA-filtered background air in the stem cell unit, but it was considerably lower than typical indoor air. Thus, in shower environments without HEPA filtration, the increase in microbial load due to shower water aerosolization would not have been distinguishable from anticipated variations in background levels.
引用
收藏
页码:5363 / 5372
页数:10
相关论文
共 72 条
[1]   Report of two fatal cases of Mycobacterium mucogenicum central nervous system infection in immunocompetent patients [J].
Adékambi, T ;
Foucault, C ;
La Scola, B ;
Drancourt, M .
JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (03) :837-840
[2]   rpoB gene sequence-based characterization of emerging non-tuberculous mycobacteria with descriptions of Mycobacterium bolletii sp nov., Mycobacterium phocaicum sp nov and Mycobacterium aubagnense sp nov. [J].
Adékambi, T ;
Berger, P ;
Raoult, D ;
Drancourt, M .
INTERNATIONAL JOURNAL OF SYSTEMATIC AND EVOLUTIONARY MICROBIOLOGY, 2006, 56 :133-143
[3]   PHYLOGENETIC IDENTIFICATION AND IN-SITU DETECTION OF INDIVIDUAL MICROBIAL-CELLS WITHOUT CULTIVATION [J].
AMANN, RI ;
LUDWIG, W ;
SCHLEIFER, KH .
MICROBIOLOGICAL REVIEWS, 1995, 59 (01) :143-169
[4]   The hospital water supply as a source of nosocomial infections [J].
Anaissie, EJ ;
Penzak, SR ;
Dignani, MC .
ARCHIVES OF INTERNAL MEDICINE, 2002, 162 (13) :1483-1492
[5]   Molecular identification of potential pathogens in water and air of a hospital therapy pool [J].
Angenent, LT ;
Kelley, ST ;
St Amand, A ;
Pace, NR ;
Hernandez, MT .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (13) :4860-4865
[6]   From soil to gut:: Bacillus cereus and its food poisoning toxins [J].
Arnesen, Lotte P. Stenfors ;
Fagerlund, Annette ;
Granum, Per Einar .
FEMS MICROBIOLOGY REVIEWS, 2008, 32 (04) :579-606
[7]  
Augustowska M, 2006, ANN AGR ENV MED, V13, P99
[8]  
Augustyn B, 2007, CRIT CARE NURSE, V27, P32
[9]   Source tracking aerosols released from land-applied class B biosolids during high-wind events [J].
Baertsch, Carolina ;
Paez-Rubio, Tania ;
Viau, Emily ;
Peccia, Jordan .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2007, 73 (14) :4522-4531
[10]   Microbial ecology of drinking water distribution systems [J].
Berry, David ;
Xi, Chuanwu ;
Raskin, Lutgarde .
CURRENT OPINION IN BIOTECHNOLOGY, 2006, 17 (03) :297-302