Hemodynamic support with the pulsatile catheter pump in a sheep model of acute heart failure

被引:8
作者
Li, Zhicheng
Gu, Y. John
Ye, Qing
Cheng, Shaofei
Wang, Weijun
Tang, Min
Zhao, Xiaogang
Rakhorst, Gerhard
Chen, Changzhi
机构
[1] Shanghai Jiao Tong Univ, Ren Ji Hosp, Dept Cardiothorac Surg, Sch Med, Shanghai 200127, Peoples R China
[2] Univ Groningen, Med Ctr, Dept Biomed Engn, Groningen, Netherlands
关键词
left ventricular assist device; catheter pump; heart failure; sheep;
D O I
10.1111/j.1525-1594.2006.00316.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study was aimed to mimic clinical heart failure (HF) conditions and to assess the effect of pulsatilecatheter (PUCA) pump support on hemodynamics and tissue perfusion in a sheep model of acute HF. In 14 sheep, HF was induced by partial occluding the middle left circumflex coronary artery combined with pacemaker-induced tachycardia. PUCA pump was then activated to support the HF for 3 h. Hemodynamic parameters were recorded at baseline, HF, and then every 30 min during experiments. Blood samples were taken in carotid artery (CA), pulmonary artery (PA), and coronary sinus (CS) for the determination of oxygen saturation (SO2) and lactate concentration as markers of tissue perfusion. Results showed that HF model was induced successfully in 10 sheep and failed in four sheep due to refractory ventricular fibrillation. PUCA pump support was successful in seven out of 10 sheep for 3 h. Three cases failed due to technical problems. After HF (n = 10), cardiac output (CO) was decreased from 3.7 +/- 0.5 to 2.0 +/- 0.5 L/min (P < 0.001). Mean arterial pressure (MAP) was lowered from 116.1 +/- 14.2 to 68.1 +/- 14.7 mm Hg (P < 0.001). In seven sheep supported with PUCA pump, MAP rose from 68.9 +/- 15.2 to 94.7 +/- 14.7 mm Hg (P = 0.005), systolic blood pressure increased from 86.6 +/- 17.0 to 112.6 +/- 17.1 mm Hg (P = 0.009), and diastolic blood pressure increased from 57.7 +/- 12.6 to 79.9 +/- 13.9 mm Hg (P = 0.011). CO remained at about 2.0 L/min. SO2 in CA, PA, and CS decreased significantly after HF (P < 0.001), with an increase after support (compared with HF, P < 0.001, 0.066 and 0.114, respectively). Lactate concentrations increased gradually in CA, PA, and CS toward the end of experiments without difference among different sampling sites. This HF model in sheep is simple, easy to manipulate, reproducible and reflecting clinical HF conditions. PUCA pump can maintain the hemodynamic status for 3 h in this acute HF model.
引用
收藏
页码:881 / 888
页数:9
相关论文
共 24 条
[11]   Organ perfusion with hemopump device assistance with and without intraaortic balloon pumping [J].
Meyns, B ;
Nishimura, Y ;
Racz, R ;
Jashari, R ;
Flameng, W .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 114 (02) :243-253
[12]  
Mihaylov D, 1997, ARTIF ORGANS, V21, P425
[13]   Development of acute ischemic heart failure in sheep [J].
Mihaylov, D ;
Reintke, H ;
Blanksma, P ;
De Jong, ED ;
Elstrodt, J ;
Rakhorst, G .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2000, 23 (05) :325-330
[14]  
Mihaylov D, 2000, Technol Health Care, V8, P251
[15]   The gastrointestinal tract: An underestimated organ as demonstrated in an experimental LVAD pig model [J].
Miyama, M ;
Dihmis, WC ;
Deleuze, PH ;
Uozaki, Y ;
Bambang, SL ;
Pasteau, F ;
Rostaqui, N ;
Loisance, DY .
ANNALS OF THORACIC SURGERY, 1996, 61 (03) :817-822
[16]  
MOE GW, 1988, J LAB CLIN MED, V112, P426
[17]   INTRAAORTIC BALLOON PUMPING IN PATIENTS REQUIRING CARDIAC OPERATIONS - RISK ANALYSIS AND LONG-TERM FOLLOW-UP [J].
NAUNHEIM, KS ;
SWARTZ, MT ;
PENNINGTON, DG ;
FIORE, AC ;
MCBRIDE, LR ;
PEIGH, PS ;
BARNETT, MG ;
VACA, KJ ;
KAISER, GC ;
WILLMAN, VL .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1992, 104 (06) :1654-1661
[18]  
NAUNHEIM KS, 1992, J THORAC CARDIOVASC, V104, P1660
[19]   MEASUREMENT OF OXYGEN-CONSUMPTION AND ARTERIAL-VENOUS OXYGEN-SATURATION FOLLOWING TOTAL ARTIFICIAL-HEART IMPLANTATION [J].
ROBISON, PD ;
PANTALOS, GM ;
LONG, JW ;
BLISS, RS ;
PRICE, DK ;
EVERETT, SD ;
GOLDMAN, P ;
GOLDENBERG, I ;
OLSEN, DB .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 (03) :135-140
[20]   A novel heart failure model induced by sequential coronary artery occlusions and tachycardiac stress in awake pigs [J].
Shen, YT ;
Lynch, JJ ;
Shannon, RP ;
Wiedmann, RT .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 277 (01) :H388-H398