A 3 years retrospective study of survival for zirconia-based single crowns fabricated from intraoral digital impressions

被引:57
作者
Gherlone, Enrico [1 ]
Mandelli, Federico [1 ]
Cappare, Paolo [1 ]
Pantaleo, Giuseppe [1 ,3 ]
Traini, Tonino [1 ,2 ]
Ferrini, Francesco [1 ]
机构
[1] Dept Dent, I-20132 Milan, Italy
[2] Univ G dAnnunzio, Dept Med Oral & Biotechnol Sci, unichi, Chieti, Italy
[3] San Raffaele Univ Milan, Fac Psychol, Milan, Italy
关键词
Zirconia crown; CAD/CAM; Chipping; Fracture; Veneer; FIXED DENTAL PROSTHESES; SUBCRITICAL CRACK-GROWTH; VENEERING CERAMICS; FRACTURE; GLASS; FRAMEWORKS; ACCURACY; WORKFLOW; STATE;
D O I
10.1016/j.jdent.2014.06.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the clinical performance of glass-ceramic/zirconia crowns fabricated using intraoral digital impressions - a retrospective study with a three-year follow-up. Methods: 70 consecutive patients with a total of 86 glass-ceramic/zirconia crowns were treated by a single clinician using standardized clinical and laboratory protocols. A complete digital workflow was adopted for the purpose except for the veneering procedure for the glass-ceramic crowns. Occlusal adjustments were made before the ceramic glazing procedure. Before cementation, all abutments where carefully cleaned with a 70% alcoholic solution and air dried. Cementation was performed using dual-curing, self-adhesive resin cement. Patients were re-examined after 12, 24 and 36 months, to assess crown chipping/fractures. Results: After the three-year follow-up, none of the zirconia-based restoration was lost ("apparent'' survival rate 100%) otherwise, the chipping rate of the veneering material increased from 9.3% after 12 months, to 14% after 24 months to 30.2% after 36 months. As a consequence, the "real'' success rate after 3 years was 69.8%. Conclusions: After 3 years the success rate of zirconia-based crowns was 69.8%, while the incidence of the chipping was 30.2%. Assuming an exponential increase in chipping rate between 12 and 36 months it can be argued that, among others, the fatigue-mechanism could be advocated as the main factor for the failure of glass-ceramic veneered zirconia especially after 24 months. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1151 / 1155
页数:5
相关论文
共 39 条
[1]   Clinical trials in zirconia: a systematic review [J].
Al-Amleh, B. ;
Lyons, K. ;
Swain, M. .
JOURNAL OF ORAL REHABILITATION, 2010, 37 (08) :641-652
[2]   Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques [J].
Almeida e Silva, Junio S. ;
Erdelt, Kurt ;
Edelhoff, Daniel ;
Araujo, Elito ;
Stimmelmayr, Michael ;
Cardoso Vieira, Luiz Clovis ;
Gueth, Jan-Frederik .
CLINICAL ORAL INVESTIGATIONS, 2014, 18 (02) :515-523
[3]   The clinical accuracy of single crowns exclusively fabricated by digital workflow-the comparison of two systems [J].
Brawek, Petya K. ;
Wolfart, Stefan ;
Endres, Lutz ;
Kirsten, Armin ;
Reich, Sven .
CLINICAL ORAL INVESTIGATIONS, 2013, 17 (09) :2119-2125
[4]   CAD/CAM ZIRCONIA VS. SLIP-CAST GLASS-INFILTRATED ALUMINA/ZIRCONIA ALL-CERAMIC CROWNS: 2-YEAR RESULTS OF A RANDOMIZED CONTROLLED CLINICAL TRIAL [J].
Cehreli, Murat Cavit ;
Kokat, Ali Murat ;
Akca, Kivanc .
JOURNAL OF APPLIED ORAL SCIENCE, 2009, 17 (01) :49-55
[5]   The state of fixed prosthodontic impressions - Room for improvement [J].
Christensen, GJ .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2005, 136 (03) :343-346
[6]   Laboratories want better impressions [J].
Christensen, Gordon J. .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2007, 138 (04) :527-529
[7]   Microstructural and crystallographic surface changes after grinding zirconia-based dental ceramics [J].
Denry, IL ;
Holloway, JA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2006, 76B (02) :440-448
[8]   State of the art of zirconia for dental applications [J].
Denry, Isabelle ;
Kelly, J. Robert .
DENTAL MATERIALS, 2008, 24 (03) :299-307
[9]  
Ender A, 2011, Int J Comput Dent, V14, P11
[10]   Effect of thermal misfit between different veneering ceramics and zirconia frameworks on in vitro fracture load of single crowns [J].
Fischer, Jens ;
Stawarczyk, Bogna ;
Tomic, Milos ;
Strub, Joerg R. ;
Haemmerle, Christoph H. F. .
DENTAL MATERIALS JOURNAL, 2007, 26 (06) :766-772