An Approach to Unbiased Subsample Interpolation for Motion Tracking

被引:25
作者
McCormick, Matthew M. [1 ]
Varghese, Tomy [2 ]
机构
[1] Kitware Inc, Clifton Pk, NY 12065 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
基金
美国国家卫生研究院;
关键词
subsample interpolation; strain imaging; motion tracking; sinc reconstruction; TIME-DELAY ESTIMATION; ECHO SIGNALS; CROSS-CORRELATION; STRAIN ESTIMATION; PHASE DELAY; ALGORITHM; ELASTOGRAPHY; VELOCITY; ESTIMATOR; IMAGES;
D O I
10.1177/0161734613476176
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Accurate subsample displacement estimation is necessary for ultrasound elastography because of the small deformations that occur and the subsequent application of a derivative operation on local displacements. Many of the commonly used subsample estimation techniques introduce significant bias errors. This article addresses a reduced bias approach to subsample displacement estimations that consists of a two-dimensional windowed-sinc interpolation with numerical optimization. It is shown that a Welch or Lanczos window with a Nelder-Mead simplex or regular-step gradient-descent optimization is well suited for this purpose. Little improvement results from a sinc window radius greater than four data samples. The strain signal-to-noise ratio (SNR) obtained in a uniformly elastic phantom is compared with other parabolic and cosine interpolation methods; it is found that the strain SNR ratio is improved over parabolic interpolation from 11.0 to 13.6 in the axial direction and 0.7 to 1.1 in the lateral direction for an applied 1% axial deformation. The improvement was most significant for small strains and displacement tracking in the lateral direction. This approach does not rely on special properties of the image or similarity function, which is demonstrated by its effectiveness with the application of a previously described regularization technique.
引用
收藏
页码:76 / 89
页数:14
相关论文
共 33 条
[1]  
[Anonymous], 1994, Scale-Space Theory in Computer Vision
[2]  
[Anonymous], 2005, The ITK Software Guide
[3]   Phase-Based Block Matching Applied to Motion Estimation with Unconventional Beamforming Strategies [J].
Basarab, Adrian ;
Gueth, Pierre ;
Liebgott, Herve ;
Delachartre, Philippe .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (05) :945-957
[4]  
Boucher R., 1981, ACOUSTICS SPEECH SIG, V29, p609
[5]   2-D locally regularized tissue strain estimation from radio-frequency ultrasound images:: Theoretical developments and results on experimental data [J].
Brusseau, Elisabeth ;
Kybic, Jan ;
Deprez, Jean-Francois ;
Basset, Olivier .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (02) :145-160
[6]   METHODS FOR ESTIMATION OF SUBSAMPLE TIME DELAYS OF DIGITIZED ECHO SIGNALS [J].
CESPEDES, I ;
HUANG, Y ;
OPHIR, J ;
SPRATT, S .
ULTRASONIC IMAGING, 1995, 17 (02) :142-171
[7]   2-D companding for noise reduction in strain imaging [J].
Chaturvedi, P ;
Insana, MF ;
Hall, TJ .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (01) :179-191
[8]  
Chen XC, 2004, IEEE T ULTRASON FERR, V51, P540, DOI 10.1109/TUFFC.2004.1320827
[9]   DETERMINATION OF TISSUE MOTION VELOCITY BY CORRELATION INTERPOLATION OF PULSED ULTRASONIC ECHO SIGNALS [J].
DEJONG, PGM ;
ARTS, T ;
HOEKS, APG ;
RENEMAN, RS .
ULTRASONIC IMAGING, 1990, 12 (02) :84-98
[10]   Phase-coupled two-dimensional speckle tracking algorithm [J].
Ebbini, ES .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (05) :972-990