Thermal pleasure in built environments: alliesthesia in different thermoregulatory zones

被引:76
作者
Parkinson, Thomas [1 ]
de Dear, Richard [1 ]
Candido, Christhina [1 ]
机构
[1] Univ Sydney, Fac Architecture Design & Planning, Sydney, NSW 2006, Australia
关键词
adaptation; air-conditioning; alliesthesia; non-steady-state environments; physiology; thermal comfort; thermal pleasure; thermoreceptors; BODY-TEMPERATURE; COMFORT; SENSATION; HUMANS; CORE; RESPONSES; EXERCISE; VALIDITY;
D O I
10.1080/09613218.2015.1059653
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The principle of thermal alliesthesia indicates that the hedonic character of a thermal environment is determined as much by the general state of the subject as by the environment itself. An environmental stimulus that offsets or counters a thermoregulatory load error will be pleasantly perceived, and vice versa. Extant empirical evidence supporting thermal alliesthesia only exists for instances of core temperature deviation. Yet the reconciliation of alliesthesia with contemporary neurophysiological discourse (in the previous paper in this series) renders the concept directly relevant to everyday experiences in built environments where core temperature rarely deviates from neutral values. New experimental data are presented that explore alliesthesia in non-steady-state conditions across three different physiological states: thermoneutral; the upper and lower fringes of the thermoneutral zone; and mild excursions into the sweating and shivering regulatory zones. Thirteen human subjects evaluated the hedonic tone of a sequence of temperature step-changes and ramps. It was found that the psychophysiological principle of thermal alliesthesia operates within the thermoneutral zone, making it equally relevant to quotidian indoor environments as it is to the extremes found in traditional physiological research. Non-steady-state built environments can potentially offer spatial alliesthesia through carefully managed contrasts between local and mean skin temperature trends. Transitional zones are suggested as design solutions.
引用
收藏
页码:20 / 33
页数:14
相关论文
共 40 条
  • [1] [Anonymous], HDB FUNDAMENTALS
  • [2] Partial- and whole-body thermal sensation and comfort - Part II: Non-uniform environmental conditions
    Arens, E
    Zhang, H
    Huizenga, C
    [J]. JOURNAL OF THERMAL BIOLOGY, 2006, 31 (1-2) : 60 - 66
  • [3] THERMAL ALLIESTHESIAL RESPONSE IN MAN IS INDEPENDENT OF SKIN LOCATION STIMULATED
    ATTIA, M
    ENGEL, P
    [J]. PHYSIOLOGY & BEHAVIOR, 1981, 27 (03) : 439 - 444
  • [4] THERMAL PLEASANTNESS SENSATION - AN INDICATOR OF THERMAL-STRESS
    ATTIA, M
    ENGEL, P
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1982, 50 (01): : 55 - 70
  • [5] Berglund L., 1977, Alliance for engineeringin Medicine and Biology, Proceedings of 30th Annual Conference on Engineering in Medicine and Biology, P274
  • [6] The ingestible telemetric body core temperature sensor: a review of validity and exercise applications
    Byrne, Christopher
    Lim, Chin Leong
    [J]. BRITISH JOURNAL OF SPORTS MEDICINE, 2007, 41 (03) : 126 - 133
  • [7] PHYSIOLOGICAL ROLE OF PLEASURE
    CABANAC, M
    [J]. SCIENCE, 1971, 173 (4002) : 1103 - +
  • [8] CHATONNET J., 1965, INT J BIO METEROROL, V9, P183, DOI 10.1007/BF02188475
  • [9] INCREASING MEAN SKIN TEMPERATURE LINEARLY REDUCES THE CORE-TEMPERATURE THRESHOLDS FOR VASOCONSTRICTION AND SHIVERING IN HUMANS
    CHENG, C
    MATSUKAWA, T
    SESSLER, DI
    OZAKI, M
    KURZ, A
    MERRIFIELD, B
    LIN, H
    OLOFSSON, P
    [J]. ANESTHESIOLOGY, 1995, 82 (05) : 1160 - 1168
  • [10] The distribution of cutaneous sudomotor and alliesthesial thermosensitivity in mildly heat-stressed humans: an open-loop approach
    Cotter, JD
    Taylor, NAS
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 2005, 565 (01): : 335 - 345