Performance evaluation of three automated human immunodeficiency virus antigen-antibody combination immunoassays

被引:53
作者
Kwon, Jung-Ah
Yoon, Soo-Young
Lee, Chang-Kyu
Lim, Chae Seung
Lee, Kap No
Sung, Hyun Ju
Brennan, Catherine A.
Devare, Sushil G.
机构
[1] Korea Univ, Coll Med, Dept Lab Med, Seoul 136701, South Korea
[2] Abbott Labs, Div Diagnost, Abbott, South Korea
[3] Abbott Labs, Div Diagnost, AIDS Res & Retrovirus Discovery, Abbott Pk, IL USA
关键词
fourth generation immunoassay; human immunodeficiency virus (HIV); p24; antigen; seroconversion;
D O I
10.1016/j.jviromet.2005.10.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Three fourth-generation antigen/antibody combination assays (Elecsys, AxSYM, Architect HIV) and two third-generation (AxSYM, Centaur) HIV antibody immunoassays were evaluated. The evaluation panel of 479 samples included: nine tissue culture derived HIV-1 strains at four different p24 antigen concentrations (n = 36), a p24 antigen sensitivity panel (n = 10), 149 HIV-1 or HIV-2 confirmed antibody positive samples, ten anti-HIV-1 positive low titer samples, three seroconversion panels (n = 2 1), and 253 HIV negative samples. The Architect had the best sensitivity for detection of HIV-1 antigen across eight HIV-1 subtypes, followed by the AxSYM while the Elecsys could not detect the highest antigen concentration evaluated (25 pg/mL) for eight of nine virus isolates. All assays showed 100% sensitivity for detection of HIV-1, group M, group 0, and HIV-2 antibody positive samples. The Architect Ag/Ab Combo assay detected the first positive bleed of the three seroconversion panels and detected infection 4-26 days earlier than the third generation assays. Based on evaluation of 253 negative samples, assay specificity varied from 98.0% to 99.6%. The Architect HIV Ag/Ab Combo exhibited the best performance for specificity and detection of p24 antigen leading to closure of seroconversion window and demonstrating its utility for early diagnosis of HIV infection. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:20 / 26
页数:7
相关论文
共 19 条
  • [1] Evaluation of four simple/rapid assays and two fourth-generation ELISAs for the identification of HIV infection on a serum panel representing the HIV-1 group M genetic diversity in Cameroon
    Aghokeng, AF
    Ewane, LO
    Awazi, B
    Nanfack, A
    Delaporte, E
    Peeters, M
    Zekeng, L
    [J]. JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2004, 37 (05) : 1632 - 1640
  • [2] Andersson S, 2004, Clin Lab, V50, P409
  • [3] Shortening of the diagnostic window with a new combined HIV p24 antigen and anti-HIV-1/2/O screening test
    Brust, S
    Duttmann, H
    Feldner, J
    Gürtler, L
    Thorstensson, R
    Simon, F
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2000, 90 (02) : 153 - 165
  • [4] Canna F, 2003, MEDICINA-BUENOS AIRE, V63, P685
  • [5] PITFALLS IN HIV TESTING - APPLICATION AND LIMITATIONS OF CURRENT TESTS
    CORDES, RJ
    RYAN, ME
    [J]. POSTGRADUATE MEDICINE, 1995, 98 (05) : 177 - &
  • [6] COUROUCE AM, 1999, GAZETTE TRANSFUSION, V155, P4
  • [7] Huang Shao-Tsung, 2005, Journal of Microbiology Immunology and Infection, V38, P65
  • [8] Seven human immunodeficiency virus (HIV) antigen-antibody combination assays: Evaluation of HIV seroconversion sensitivity and subtype detection
    Ly, TD
    Martin, L
    Daghfal, D
    Sandridge, A
    West, D
    Bristow, R
    Chalouas, L
    Qiu, XX
    Lou, SC
    Hunt, JC
    Schochetman, G
    Devare, SG
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (09) : 3122 - 3128
  • [9] Evaluation of the sensitivity and specificity of six HIV combined p24 antigen and antibody assays
    Ly, TD
    Laperche, S
    Brennan, C
    Vallari, A
    Ebel, A
    Hunt, J
    Martin, L
    Daghfal, D
    Schochetman, G
    Devare, S
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2004, 122 (02) : 185 - 194
  • [10] McElborough D, 2004, Commun Dis Public Health, V7, P312