Application of Synchrotron X-ray Microtomography for Visualizing Bacterial Biofilms 3D Microstructure in Porous Media

被引:15
|
作者
du Roscoat, S. Rolland [1 ,2 ]
Martins, J. M. F. [3 ]
Sechet, P. [4 ]
Vince, E. [3 ]
Latil, P. [1 ]
Geindreau, C. [1 ]
机构
[1] Univ Grenoble 1, Grenoble INP, Lab 3SR, UMR CNRS 5521, F-38041 Grenoble 9, France
[2] European Synchrotron Radiat Facil, F-38043 Grenoble 9, France
[3] Univ Grenoble 1, Grenoble INP, Lab Etud Transferts Hydrol & Environm LTHE, UMR CNRS 5564, F-38041 Grenoble 9, France
[4] Univ Grenoble 1, Grenoble INP, LEGI, UMR CNRS 5519, F-38041 Grenoble 9, France
关键词
biofilm; microtomography; biofilter; porous media; TRANSPORT; FLOW;
D O I
10.1002/bit.25168
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The development of reliable models to accurately predict biofilm growth in porous media relies on a good knowledge of the temporal evolution of biofilms structure within the porous network. Since little is known on the true 3D structure of biofilms developed in porous media, this work aimed at developing a new experimental protocol to visualize the 3D microstructure of bacterial biofilms in porous media. The main originality of the proposed procedure lies on the combination of the more recent advances in synchrotron microtomography (Paganin mode) and of a new contrast agent (1-chloronaphtalene) that has never been applied to biofilm visualization. It is shown that the proposed methodology takes advantage of the contrasting properties of 1-chloronaphtalene to prevent some limitations observed with more classical contrast agents. A quantitative analysis of the microstructural properties (volume fractions and specific surface area) of bacterial biofilms developed in columns of clay beads is also proposed on the basis of the obtained 3D images. Biotechnol. Bioeng. 2014;111: 1265-1271. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1265 / 1271
页数:7
相关论文
共 50 条
  • [1] Distribution of local void ratio in porous media systems from 3D X-ray microtomography images
    Al-Raoush, R
    Alshibli, KA
    PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2006, 361 (02) : 441 - 456
  • [2] 3D imaging of fracture propagation using synchrotron X-ray microtomography
    Renard, Francois
    Bernard, Dominique
    Desrues, Jacques
    Ougier-Simonin, Audrey
    EARTH AND PLANETARY SCIENCE LETTERS, 2009, 286 (1-2) : 285 - 291
  • [3] Imaging biofilm in porous media using X-ray computed microtomography
    Davit, Y.
    Iltis, G.
    Debenest, G.
    Veran-Tissoires, S.
    Wildenschild, D.
    Gerino, M.
    Quintard, M.
    JOURNAL OF MICROSCOPY, 2011, 242 (01) : 15 - 25
  • [4] First visualisation of bacterial biofilms in 3D porous media with neutron microtomography without contrast agent
    du Roscoat, Sabine Rolland
    Ivankovic, Tomislav
    Lenoir, Nicolas
    Dekic, Svjetlana
    Martins, Jean M. F.
    Geindreau, Christian
    JOURNAL OF MICROSCOPY, 2022, 285 (01) : 20 - 28
  • [5] Direct characterization of solute transport in unsaturated porous media using fast X-ray synchrotron microtomography
    Hasan, Sharul
    Niasar, Vahid
    Karadimitriou, Nikolaos K.
    Godinho, Jose R. A.
    Vo, Nghia T.
    An, Senyou
    Rabbani, Arash
    Steeb, Holger
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2020, 117 (38) : 23443 - 23449
  • [6] Synchrotron X-ray microtomography and 3D image analysis of medium density fiberboard (MDF)
    Walther, Thomas
    Thoemen, Heiko
    HOLZFORSCHUNG, 2009, 63 (05) : 581 - 587
  • [7] Foam trapping in a 3D porous medium:in situobservations by ultra-fast X-ray microtomography
    Poryles, Raphael
    Gland, Nicolas
    King, Andrew
    Rosenberg, Elisabeth
    Barre, Loic
    Chevalier, Thibaud
    SOFT MATTER, 2020, 16 (27) : 6354 - 6361
  • [8] Imaging biofilm architecture within porous media using synchrotron-based X-ray computed microtomography
    Iltis, Gabriel C.
    Armstrong, Ryan T.
    Jansik, Danielle P.
    Wood, Brian D.
    Wildenschild, Dorthe
    WATER RESOURCES RESEARCH, 2011, 47
  • [9] Resolving power of 3D x-ray microtomography systems
    Seifert, A
    Flynn, MJ
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 407 - 413
  • [10] Development and evaluation of an experimental protocol for 3-D visualization and characterization of the structure of bacterial biofilms in porous media using laboratory X-ray tomography
    Ivankovic, Tomislav
    du Roscoat, Sabine Rolland
    Geindreau, Christian
    Sechet, Philipe
    Huang, Zhujun
    Martins, Jean M. F.
    BIOFOULING, 2016, 32 (10) : 1235 - 1244