Diagnostic accuracy of magnetic resonance imaging for the detection of pulmonary nodules simulated in a dedicated porcine chest phantom

被引:7
作者
Bonert, Madeleine [1 ]
Schneider, Moritz [1 ,2 ]
Solyanik, Olga [1 ]
Hellbach, Katharina [1 ]
Bondesson, David [1 ,2 ]
Gaass, Thomas [1 ]
Thaens, Natalie [1 ,2 ]
Ricke, Jens [1 ]
Benkert, Thomas [3 ]
Dinkel, Julien [1 ,2 ]
机构
[1] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiol, Munich, Germany
[2] German Ctr Lung Res, Comprehens Pneumol Ctr, Munich, Germany
[3] Siemens Healthcare GmbH, MR Applicat Predev, Erlangen, Germany
来源
PLOS ONE | 2020年 / 15卷 / 12期
关键词
COMPUTED-TOMOGRAPHY; LUNG; MR; STATISTICS; CT;
D O I
10.1371/journal.pone.0244382
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective CT serves as gold standard for the evaluation of pulmonary nodules. However, CT exposes patients to ionizing radiation, a concern especially in screening scenarios with repeated examinations. Due to recent technological advances, MRI emerges as a potential alternative for lung imaging using 3D steady state free precession and ultra-short echo-time sequences. Therefore, in this study we assessed the performance of three state-of-the-art MRI sequences for the evaluation of pulmonary nodules. Methods Lesions of variable sizes were simulated in porcine lungs placed in a dedicated chest phantom mimicking a human thorax, followed by CT and MRI examinations. Two blinded readers evaluated the acquired MR-images locating and measuring every suspect lesion. Using the CT-images as reference, logistic regression was performed to investigate the sensitivity of the tested MRI-sequences for the detection of pulmonary nodules. Results For nodules with a diameter of 6 mm, all three sequences achieved high sensitivity values above 0.91. However, the sensitivity dropped for smaller nodules, yielding an average of 0.83 for lesions with 4 mm in diameter and less than 0.69 for lesions with 2 mm in diameter. The positive predictive values ranged between 0.91 and 0.96, indicating a low amount of false positive findings. Furthermore, the size measurements done on the MR-images were subject to a bias ranging from 0.83 mm to -1.77 mm with standard deviations ranging from 1.40 mm to 2.11 mm. There was no statistically significant difference between the three tested sequences. Conclusion While showing promising sensitivity values for lesions larger than 4 mm, MRI appears to be not yet suited for lung cancer screening. Nonetheless, the three tested MRI sequences yielded high positive predictive values and accurate size measurements; therefore, MRI could potentially figure as imaging method of the chest in selected follow-up scenarios, e.g. of incidental findings subject to the Fleischner Criteria.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Diagnostic accuracy of 3-T lung magnetic resonance imaging in human immunodeficiency virus-positive children
    Rana, Pratyaksha
    Sodhi, Kushaljit Singh
    Bhatia, Anmol
    Saxena, Akshay Kumar
    Suri, Deepti
    Singh, Surjit
    [J]. PEDIATRIC RADIOLOGY, 2020, 50 (01) : 38 - 45
  • [22] Magnetic resonance imaging for paediatric retroperitoneal masses: Diagnostic accuracy of the claw sign
    Combrink, Lisa
    Beviss-Challinor, Kenneth B.
    [J]. SA JOURNAL OF RADIOLOGY, 2021, 25 (01):
  • [23] Diagnostic Accuracy of Magnetic Resonance Imaging versus Clinical Staging in Cervical Cancer
    Shirazi, Ahmad Soltani
    Razi, Taghi
    Cheraghi, Fatemeh
    Rahim, Fakher
    Ehsani, Sara
    Davoodi, Mohammad
    [J]. ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (14) : 5729 - 5732
  • [24] Diagnostic Accuracy of an iPhone DICOM Viewer for the Interpretation of Magnetic Resonance Imaging of the Knee
    De Maio, Peter
    White, Lawrence M.
    Bleakney, Robert
    Menezes, Ravi J.
    Theodoropoulos, John
    [J]. CLINICAL JOURNAL OF SPORT MEDICINE, 2014, 24 (04): : 308 - 314
  • [25] Diagnostic Accuracy of Sonography Versus Magnetic Resonance Imaging for Primary Nasopharyngeal Carcinoma
    Gao, Yong
    Zhu, Shang-Yong
    Dai, Yi
    Lu, Bing-Feng
    Lu, Lu
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (05) : 827 - 834
  • [26] Comparison of Chest Dual-energy Subtraction Digital Tomosynthesis Imaging and Dual-energy Subtraction Radiography to Detect Simulated Pulmonary Nodules with and without Calcifications: A Phantom Study
    Gomi, Tsutomu
    Nakajima, Masahiro
    Fujiwara, Hiroki
    Umeda, Tokuo
    [J]. ACADEMIC RADIOLOGY, 2011, 18 (02) : 191 - 196
  • [27] Detection of body packing by magnetic resonance imaging: a new diagnostic tool?
    Bulakci, Mesut
    Ozbakir, Bora
    Kiris, Adem
    [J]. ABDOMINAL IMAGING, 2013, 38 (03): : 436 - 441
  • [28] Accuracy of computed tomography: magnetic resonance imaging image fusion using a phantom for skull base surgery
    Hirano, Toru
    Ichikawa, Katsuhiro
    Wanibuchi, Masahiko
    Mikami, Takeshi
    Suzuki, Junpei
    Nagahama, Hiroshi
    Mikuni, Nobuhiro
    [J]. JOURNAL OF NEUROSURGICAL SCIENCES, 2019, 66 (01) : 9 - 16
  • [29] Synthetic head and neck and phantom images for determining deformable image registration accuracy in magnetic resonance imaging
    Ger, Rachel B.
    Yang, Jinzhong
    Ding, Yao
    Jacobsen, Megan C.
    Cardenas, Carlos E.
    Fuller, Clifton D.
    Howell, Rebecca M.
    Li, Heng
    Stafford, R. Jason
    Zhou, Shouhao
    Court, Laurence E.
    [J]. MEDICAL PHYSICS, 2018, 45 (09) : 4315 - 4321
  • [30] Diagnostic Accuracy of Magnetic Resonance Imaging and Computed Tomography Scan in Young Athletes With Spondylolysis
    West, Amy M.
    d'Hemecourt, Pierre A.
    Bono, Olivia J.
    Micheli, Lyle J.
    Sugimoto, Dai
    [J]. CLINICAL PEDIATRICS, 2019, 58 (06) : 671 - 676