Effect of displacement and humidity on contact resistance of copper electrical contacts

被引:50
作者
Sung, I. H. [1 ]
Kim, J. W. [1 ]
Noh, H. J. [1 ]
Jang, H. [1 ]
机构
[1] Korea Univ, Dept Mat Sci & Engn, Seoul 136713, South Korea
关键词
Fretting; Contact area; Humidity; Contact resistance; FRETTING CORROSION; WATER-VAPOR; WEAR; CONNECTORS; ADHESION; FRICTION; SURFACES; BEHAVIOR; ALLOY; FILMS;
D O I
10.1016/j.triboint.2015.11.027
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The effect of displacement and humidity on fretting-induced instability of electrical contact resistance (Re) was studied. A fretting tester was used to examine R-c in partial and gross slip modes. Under the partial slip regime the contact failure was susceptible to the displacement and moisture effectively increased contact stability, which was pronounced at smaller displacements. In the gross slip mode, however, humidity effect was relatively small. The early contact failure at low humidity was attributed to the wear debris agglomeration within the sliding interface, suggesting a high propensity of electrical contact failure at dry conditions. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:256 / 261
页数:6
相关论文
共 23 条
[1]  
[Anonymous], P IEEE HOLM C EL CON
[2]   SURVEY OF CONTACT FRETTING IN ELECTRICAL CONNECTORS [J].
ANTLER, M .
IEEE TRANSACTIONS ON COMPONENTS HYBRIDS AND MANUFACTURING TECHNOLOGY, 1985, 8 (01) :87-104
[3]  
Bock E. M., 1974, P 20 ANN HOLM SEM EL, P128
[4]  
Braunovic M, 1989, COMPONENTS HYBRIDS M, V12, P215
[5]   RESISTANCE BUILDUP IN ELECTRICAL CONNECTORS DUE TO FRETTING CORROSION OF ROUGH SURFACES [J].
BRYANT, MD .
IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY PART A, 1994, 17 (01) :86-95
[6]   Torsional fretting wear behaviour of 7075 aluminium alloy in various relative humidity environments [J].
Cai, Zhenbing ;
Zhu, Minhao ;
Shen, Huoming ;
Zhou, Zhongrong ;
Jin, Xuesong .
WEAR, 2009, 267 (1-4) :330-339
[7]   Experimental study by means of thin layer activation of the humidity influence on the fretting wear of steel surfaces [J].
de Baets, P ;
Kalacska, G ;
Strijckmans, K ;
Van de Velde, F ;
Van Peteghem, AP .
WEAR, 1998, 216 (02) :131-137
[8]   CONTACT ADHESION OF THIN GOLD-FILMS ON ELASTOMERIC SUPPORTS - COLD WELDING UNDER AMBIENT CONDITIONS [J].
FERGUSON, GS ;
CHAUDHURY, MK ;
SIGAL, GB ;
WHITESIDES, GM .
SCIENCE, 1991, 253 (5021) :776-778
[9]   Introduction of an exponential formulation to quantify the electrical endurance of micro-contacts enduring fretting wear: Application to Sn, Ag and Au coatings [J].
Fouvry, S. ;
Jedrzejczyk, P. ;
Chalandon, P. .
WEAR, 2011, 271 (9-10) :1524-1534
[10]   THE INFLUENCE OF WATER-VAPOR IN AIR ON THE FRICTION BEHAVIOR OF PURE METALS DURING FRETTING [J].
GOTO, H ;
BUCKLEY, DH .
TRIBOLOGY INTERNATIONAL, 1985, 18 (04) :237-245