New after-laying test methods for XLPE cable lines

被引:0
|
作者
Uchida, K
Kobayashi, S
Kawashima, T
Hirotsu, K
Inoue, H
Tanaka, H
Sakuma, S
机构
关键词
after-laying test; damped oscillating wave; very low frequency; CV cable; partial discharge; electrical tree;
D O I
10.1002/eej.4391170603
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An after-laying test is required to demonstrate the soundness of XLPE underground cable lines with joints. AC voltage application is desirable for the test; however, the equipment for ac application must be very large because it must supply large capacitive current for cables. DC voltage is normally applied, which can be supplied with small equipment; however, the effectiveness of the de application is questioned because the electrical stress distribution is quite different from that with ac application and, moreover, de application could damage insulation properties of cables. The authors targeted the Oscillating Wave (OSW) method and the Very Low-Frequency (VLF) method as alternative after-laying tests. They first developed modeling methods of various defects on underground cable lines and applied OSW and VLF to these defect models. They found that OSW and VLF methods have higher fault detection capability than de voltage application. They also demonstrated that the defects which can be easily detected with the OSW method are difficult to detect with the VLF method and vice versa. They showed that serial application of both methods highly improve the fault detection ability for XLPE underground cable lines.
引用
收藏
页码:18 / 30
页数:13
相关论文
共 50 条
  • [1] New after-laying test methods for XLPE cable lines
    Uchida, Katsuki
    Kobayashi, Shin'ichi
    Kawashima, Takao
    Hirotsu, Ken'ichi
    Inoue, Hitoshi
    Tanaka, Hideo
    Sakuma, Susumu
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 1996, 117 (06): : 18 - 30
  • [2] Results on after-laying test of 275kV XLPE cable line
    Kobayashi, S
    Kawabe, T
    Morimoto, N
    Shinoda, A
    Shimohiro, D
    Kawai, T
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 1202 - 1205
  • [3] APPLICATION OF ADVANCED AFTER-LAYING TEST TO LONG-DISTANCE 275-KV XLPE CABLE LINES
    OTA, H
    ICHIHARA, M
    MIYAMOTO, N
    KITAI, S
    MARUYAMA, Y
    FUKASAWA, M
    TAKEHANA, H
    IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (02) : 567 - 579
  • [5] Study on an after-laying test for a long-distance GIL
    Nojima, T
    Shimizu, M
    Miyazaki, A
    IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (03) : 718 - 727
  • [6] PD Measurement Technique for After-laying Test of Large-scale 110-500kV Cable Circuit
    Chen, Min
    Urano, Koji
    Kon, Dewu
    Sun, Tingxi
    2016 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2016, : 231 - 234
  • [7] A study on the oscillating wave voltage test as an after-laying test for distribution power cables
    Koo, JY
    Kim, JT
    Lee, JS
    Kim, SJ
    Song, IK
    Kim, JY
    Cho, YO
    IEEE 1997 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I AND II, 1997, : 334 - 337
  • [8] Selectivity of damped ac (DAC) and VLF voltages in after-laying tests of extruded MV cable systems
    Oyegoke, B
    Hyvonen, P
    Aro, M
    Gao, N
    Danikas, M
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2003, 10 (05) : 874 - 882
  • [9] Test of residual stresses in XLPE cable
    Chen, Jubing
    Shen, Yong
    Yu, Zhong
    Zhou, Yan
    Zhang, Mingjie
    Gaodianya Jishu/High Voltage Engineering, 2004, 30 (03):
  • [10] Study on detection for the defects of XLPE cable lines
    Uchida, K
    Tanaka, H
    Hirotsu, K
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (02) : 663 - 668