Noninvasive quantitation of human liver steatosis using magnetic resonance and bioassay methods

被引:98
作者
d'Assignies, Gaspard
Ruel, Martin
Khiat, Abdesslem
Lepanto, Luigi
Chagnon, Miguel [3 ]
Kauffmann, Claude
Tang, An
Gaboury, Louis [2 ]
Boulanger, Yvan [1 ]
机构
[1] CHUM, Hop St Luc, Dept Radiol, Montreal, PQ H2X 3J4, Canada
[2] CHUM, Dept Anatomopathol, Montreal, PQ H2X 3J4, Canada
[3] Univ Montreal, Dept Math & Stat, Montreal, PQ H3C 3J7, Canada
基金
加拿大健康研究院;
关键词
Liver steatosis; MRI; Magnetic resonance spectroscopy; Histopathology; Fat quantitation; FAT-CONTENT; DISEASE; SPECTROSCOPY; MR; QUANTIFICATION; BIOPSY; PROGRESSION;
D O I
10.1007/s00330-009-1351-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose was to evaluate the ability of three magnetic resonance (MR) techniques to detect liver steatosis and to determine which noninvasive technique (MR, bioassays) or combination of techniques is optimal for the quantification of hepatic fat using histopathology as a reference. Twenty patients with histopathologically proven steatosis and 24 control subjects underwent single-voxel proton MR spectroscopy (MRS; 3 voxels), dual-echo in phase/out of phase MR imaging (DEI) and diffusion-weighted MR imaging (DWI) examinations of the liver. Blood or urine bioassays were also performed for steatosis patients. Both MRS and DEI data allowed to detect steatosis with a high sensitivity (0.95 for MRS; 1 for DEI) and specificity (1 for MRS; 0.875 for DEI) but not DWI. Strong correlations were found between fat fraction (FF) measured by MRS, DEI and histopathology segmentation as well as with low density lipoprotein (LDL) and cholesterol concentrations. A Bland-Altman analysis showed a good agreement between the FF measured by MRS and DEI. Partial correlation analyses failed to improve the correlation with segmentation FF when MRS or DEI data were combined with bioassay results. Therefore, FF from MRS or DEI appear to be the best parameters to both detect steatosis and accurately quantify fat liver noninvasively.
引用
收藏
页码:2033 / 2040
页数:8
相关论文
共 26 条
[1]   Nonalcoholic fatty liver disease [J].
Brunt, Elizabeth M. ;
Wong, Vincent W. -S. ;
Nobili, Valerio ;
Day, Christopher P. ;
Sookoian, Silvia ;
Maher, Jacquelyn J. ;
Bugianesi, Elisabetta ;
Sirlin, Claude B. ;
Neuschwander-Tetri, BrentA. ;
Rinella, Mary E. .
NATURE REVIEWS DISEASE PRIMERS, 2015, 1
[2]   Diffusion-weighted MR imaging of the liver of hepatitis C patients [J].
Boulanger, Y ;
Amara, M ;
Lepanto, L ;
Beaudoin, G ;
Nguyen, BN ;
Allaire, G ;
Poliquin, M ;
Nicolet, V .
NMR IN BIOMEDICINE, 2003, 16 (03) :132-136
[3]   Relaxation effects in the quantification of fat using gradient echo imaging [J].
Bydder, Mark ;
Yokoo, Takeshi ;
Hamilton, Gavin ;
Middleton, Michael S. ;
Chavez, Alyssa D. ;
Schwimmer, Jeffrey B. ;
Lavine, Joel E. ;
Sirlin, Claude B. .
MAGNETIC RESONANCE IMAGING, 2008, 26 (03) :347-359
[4]  
Canbakan B, 2007, ACTA GASTRO-ENT BELG, V70, P277
[5]   Pain experienced during percutaneous liver biopsy [J].
Castéra, L ;
Nègre, I ;
Samii, K ;
Buffet, C .
HEPATOLOGY, 1999, 30 (06) :1529-1530
[6]  
Charatcharoenwitthaya Phunchai, 2007, Clin Liver Dis, V11, P37, DOI 10.1016/j.cld.2007.02.014
[7]   Measurement of liver fat content using selective saturation at 3.0 T [J].
Cotler, Scott J. ;
Guzman, Grace ;
Layden-Almer, Jennifer ;
Mazzone, Theodore ;
Layden, Thomas J. ;
Zhou, Xiaohong Joe .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (04) :743-748
[8]   Nonalcoholic fatty liver disease: From steatosis to cirrhosis [J].
Farrell, GC ;
Larter, CZ .
HEPATOLOGY, 2006, 43 (02) :S99-S112
[9]   Hepatic fat fraction: MR imaging for quantitative measurement and display - Early experience [J].
Hussain, HK ;
Chenevert, TL ;
Londy, FJ ;
Gulani, V ;
Swanson, SD ;
McKenna, BJ ;
Appelman, HD ;
Adusumilli, S ;
Greenson, JK ;
Conjeevaram, HS .
RADIOLOGY, 2005, 237 (03) :1048-1055
[10]   Assessment of the variations in fat content in normal liver using a fast MR imaging method in comparison with results obtained by spectroscopic imaging [J].
Irwan, Roy ;
Edens, Mireille A. ;
Sijens, Paul E. .
EUROPEAN RADIOLOGY, 2008, 18 (04) :806-813