Effectiveness of a tiny tuned liquid damper on mitigating wind-induced responses of cylindrical solar tower based on elastic wind tunnel tests

被引:13
作者
Li, Yafeng [1 ]
Li, Shouying [1 ]
Sun, Beisong [1 ]
Liu, Min [1 ]
Chen, Zhengqing [1 ]
机构
[1] Hunan Univ, Coll Civil Engn, Key Lab Wind & Bridge Engn Hunan Prov, Changsha 410082, Peoples R China
关键词
Tuned liquid damper (TLD); Wind-induced responses; Elastic test model; Wind tunnel tests; COLUMN DAMPERS; SUPPRESSION; VIBRATION; MOTION; FLUID; TLD;
D O I
10.1016/j.jweia.2020.104455
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A tiny TLD was specially designed and manufactured to investigate its effectiveness on mitigating the wind-induced responses of a 243-meter-high solar tower by using wind tunnel tests based on an elastic WA model. First, an elastic WA model of the solar tower was made, and its structural parameters, including natural frequency, the first three mode shapes and structural damping ratio, were identified. Second, six types of tiny TLDs with different inner diameters (9, 10, 11, 12, 13 and 14 mm) were designed and manufactured, and the natural frequency and sloshing damping ratio of water in these tiny TLDs were identified to compare them with the theoretical values. The results show the measured and theoretical natural frequencies agree well with each other, while the measured sloshing damping of water is much larger than the theoretical value. Then, a series of wind tunnel tests were carried out to obtain the wind-induced responses of the solar tower. The effectiveness of TLD on mitigating the wind-induced responses of the solar tower was systematically investigated based on a series of parametric studies. The results show the wind-induced responses in the cross-wind and along-wind directions, including the acceleration at the top, the shear and moment at the bottom, can all be significantly reduced by the tiny TLDs with optimized parameters. It seems that the efficiency of the TLDs at the vortex-induced vibration critical wind velocity is significantly higher than that at the design wind velocity. In addition, the parametric studies indicate that the effectiveness of the TLDs is considerably sensitive to the frequency ratio, the height of the TLDs and the mass ratio.
引用
收藏
页数:9
相关论文
共 44 条
  • [1] Abramson H.N., 1966, NASA SPECIAL PUBLICA, V7, P106
  • [2] A semi-active tuned liquid column damper for lateral vibration control of high-rise structures: Theory and experimental verification
    Altay, Okyay
    Klinkel, Sven
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (12)
  • [3] Vibration control of various types of buildings using TLCD
    Balendra, T
    Wang, CM
    Rakesh, G
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1999, 83 : 197 - 208
  • [4] Mitigation of wind-induced accelerations using Tuned Liquid Column Dampers: Experimental and numerical studies
    Cammelli, Stefano
    Li, Yin Fai
    Mijorski, Sergey
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2016, 155 : 174 - 181
  • [5] Modelling of a tuned liquid damper with inclined damping screens
    Cassolato, M. R.
    Love, J. S.
    Tait, M. J.
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2011, 18 (06) : 674 - 681
  • [6] Suppression of vortex-excited vibration of tall buildings using tuned liquid dampers
    Chang, CC
    Gu, M
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1999, 83 : 225 - 237
  • [7] Spherical tuned liquid damper for vibration control in wind turbines
    Chen, Jun-Ling
    Georgakis, Christos T.
    [J]. JOURNAL OF VIBRATION AND CONTROL, 2015, 21 (10) : 1875 - 1885
  • [8] Colucci F., 2019, LECT NOTES COMPUT SC, V59, P72
  • [9] flowner G.W., 1963, B SEISMOL SOC AM, V53, P381
  • [10] TUNED LIQUID DAMPER (TLD) FOR SUPPRESSING HORIZONTAL MOTION OF STRUCTURES
    FUJINO, Y
    SUN, L
    PACHECO, BM
    CHAISERI, P
    [J]. JOURNAL OF ENGINEERING MECHANICS-ASCE, 1992, 118 (10): : 2017 - 2030