Thermal response test for ground source heat pump based on constant temperature and heat-flux methods

被引:25
作者
Yu, Xiaohui [1 ,2 ]
Zhang, Yufeng [1 ,2 ]
Deng, Na [1 ]
Ma, Hongting [1 ]
Dong, Shengming [1 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[2] Collaborat Innovat Ctr Chem Sci & Engn, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
Ground source heat pump; Ground heat exchanger; Thermal response test; Ground temperature profile; Multi-layer cylindrical source model; EXCHANGERS; RESISTANCE; SYSTEMS;
D O I
10.1016/j.applthermaleng.2015.10.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
TRT has been a useful and consolidated tool to determine the ground thermal properties for GSHP. In this paper, six TRTs were carried out to analyze the heat transfer performance of GHE based on constant temperature and heat-flux methods. Vertical temperatures were measured using temperature sensors installed along GHE pipes. A multi-layer cylindrical source model was developed to estimate thermal conductivity distributions in the ground around GHE based on the vertical temperatures. The results showed that the constant temperature method had many advantages in shortening test period, operating stability and test accuracy compared with the traditional constant heat-flux method. The estimated thermal conductivities obtained based on the multi-layer cylindrical source model were consistent with the geological conditions and groundwater aquifer. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:678 / 682
页数:5
相关论文
共 18 条
[1]   Borehole resistance and vertical temperature profiles in coaxial borehole heat exchangers [J].
Beier, Richard A. ;
Acuna, Jose ;
Mogensen, Palne ;
Palm, Bjorn .
APPLIED ENERGY, 2013, 102 :665-675
[2]   Borehole thermal response and thermal resistance of four different grouting materials measured with a TRT [J].
Borinaga-Trevino, Roque ;
Pascual-Munoz, Pablo ;
Castro-Fresno, Daniel ;
Blanco-Fernandez, Elena .
APPLIED THERMAL ENGINEERING, 2013, 53 (01) :13-20
[3]   Investigations on the influence of aquifers on the ground temperature in ground-source heat pump operation [J].
Capozza, Antonio ;
De Carli, Michele ;
Zarrella, Angelo .
APPLIED ENERGY, 2013, 107 :350-363
[4]  
DEERMAN JD, 1991, ASHRAE TRAN, V97, P287
[5]   An improved thermal response test for U-tube ground heat exchanger based on optical fiber thermometers [J].
Fujii, Hikari ;
Okubo, Hiroaki ;
Nishi, Keita ;
Itoi, Ryuichi ;
Ohyama, Kunio ;
Shibata, Kazuo .
GEOTHERMICS, 2009, 38 (04) :399-406
[6]  
Gehlin S.E. A., 2003, ASHRAE T, V109, P131
[7]   Thermal performances of different types of underground heat exchangers [J].
Li, XG ;
Chen, Y ;
Chen, ZH ;
Zhao, J .
ENERGY AND BUILDINGS, 2006, 38 (05) :543-547
[8]   On the estimation of thermal resistance in borehole thermal conductivity test [J].
Marcotte, D. ;
Pasquier, P. .
RENEWABLE ENERGY, 2008, 33 (11) :2407-2415
[9]   Modeling approaches applied to the thermal response test: A critical review of the literature [J].
Rainieri, Sara ;
Bozzoli, Fabio ;
Pagliarini, Giorgio .
HVAC&R RESEARCH, 2011, 17 (06) :977-990
[10]  