Detection of pulmonary fat embolism with dual-energy CT: an experimental study in rabbits

被引:6
作者
Tang, Chun Xiang [1 ]
Zhou, Chang Sheng [1 ]
Zhao, Yan E. [1 ]
Schoepf, U. Joseph [1 ,2 ]
Mangold, Stefanie [2 ]
Ball, B. Devon [2 ]
Han, Zong Hong [1 ]
Qi, Li [1 ]
Zhang, Long Jiang [1 ]
Lu, Guang Ming [1 ]
机构
[1] Nanjing Univ, Jinling Hosp, Dept Med Imaging, Sch Med, Nanjing 210002, Jiangsu, Peoples R China
[2] Med Univ South Carolina, Div Cardiovasc Imaging, Dept Radiol & Radiol Sci, Ashley River Tower,MSC 226,25 Courtenay Dr, Charleston, SC 29401 USA
关键词
Pulmonary fat embolism; CT pulmonary angiography; Dual-energy CT; Lung perfusion blood volume; Animal model; EMISSION COMPUTED-TOMOGRAPHY; PERFUSION BLOOD-VOLUME; LUNG; QUANTIFICATION; ANGIOGRAPHY; DIAGNOSIS; CANINES;
D O I
10.1007/s00330-016-4512-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the use of dual-energy CT imaging of the lung perfused blood volume (PBV) for the detection of pulmonary fat embolism (PFE). Dual-energy CT was performed in 24 rabbits before and 1 hour, 1 day, 4 days and 7 days after artificial induction of PFE via the right ear vein. CT pulmonary angiography (CTPA) and lung PBV images were evaluated by two radiologists, who recorded the presence, number, and location of PFE on a per-lobe basis. Sensitivity, specificity, and accuracy of CTPA and lung PBV for detecting PFE were calculated using histopathological evaluation as the reference standard. A total of 144 lung lobes in 24 rabbits were evaluated and 70 fat emboli were detected on histopathological analysis. The overall sensitivity, specificity and accuracy were 25.4 %, 98.6 %, and 62.5 % for CTPA, and 82.6 %, 76.0 %, and 79.2 % for lung PBV. Higher sensitivity (p < 0.001) and accuracy (p < 0.01), but lower specificity (p < 0.001), were found for lung PBV compared with CTPA. Dual-energy CT can detect PFE earlier than CTPA (all p < 0.01). Dual-energy CT provided higher sensitivity and accuracy in the detection of PFE as well as earlier detection compared with conventional CTPA in this animal model study. aEuro cent Fat embolism occurs commonly in patients with traumatic bone injury. aEuro cent Dual-energy CT improves diagnostic performance for pulmonary fat embolism detection. aEuro cent Dual-energy CT can detect pulmonary fat embolism earlier than CTPA.
引用
收藏
页码:1377 / 1385
页数:9
相关论文
共 30 条
  • [1] Pulmonary fat embolism syndrome: CT findings in six patients
    Arakawa, H
    Kurihara, Y
    Nakajima, Y
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (01) : 24 - 29
  • [2] Lung perfusion analysis with dual energy CT in patients with suspected pulmonary embolism-Influence of window settings on the diagnosis of underlying pathologies of perfusion defects
    Bauer, Ralf W.
    Kerl, J. Matthias
    Weber, Eva
    Weisser, Philipp
    Korkusuz, Huedayi
    Lehnert, Thomas
    Jacobi, Volkmar
    Vogl, Thomas J.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : E476 - E482
  • [3] Dual energy CT pulmonary blood volume assessment in acute pulmonary embolism - correlation with D-dimer level, right heart strain and clinical outcome
    Bauer, Ralf W.
    Frellesen, Claudia
    Renker, Matthias
    Schell, Boris
    Lehnert, Thomas
    Ackermann, Hanns
    Schoepf, U. Joseph
    Jacobi, Volkmar
    Vogl, Thomas J.
    Kerl, J. Matthias
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (09) : 1914 - 1921
  • [4] Acute and subacute dual energy CT findings of pulmonary embolism in rabbits: correlation with histopathology
    Chai, X.
    Zhang, L-J
    Yeh, B. M.
    Zhao, Y-E
    Hu, X-B
    Lu, G-M
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1013) : 613 - 622
  • [5] Nontraumatic pulmonary fat embolism syndrome: Radiologic and pathologic correlations
    Choi, JA
    Oh, YW
    Kim, HK
    Kang, KH
    Choi, YH
    Kang, EY
    [J]. JOURNAL OF THORACIC IMAGING, 2002, 17 (02) : 167 - 169
  • [6] Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution
    Ferda, Jiri
    Ferdova, Eva
    Mirka, Hynek
    Baxa, Jan
    Bednarova, Alena
    Flohr, Thomas
    Schmidt, Bernhard
    Matejovic, Martin
    Kreuzberg, Boris
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2011, 77 (02) : 287 - 293
  • [7] Nodular pattern at lung computed tomography in fat embolism syndrome -: A helpful finding
    Gallardo, X
    Castañer, E
    Mata, JM
    Rimola, J
    Branera, J
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (02) : 254 - 257
  • [8] Hofmann S, 1998, ANAESTHESIA, V53, P35
  • [9] Inoue Hiromasa, 2008, Legal Medicine, V10, P26, DOI 10.1016/j.legalmed.2007.07.001
  • [10] Material differentiation by dual energy CT: initial experience
    Johnson, Thorsten R. C.
    Krauss, Bernhard
    Sedlmair, Martin
    Grasruck, Michael
    Bruder, Herbert
    Morhard, Dominik
    Fink, Christian
    Weckbach, Sabine
    Lenhard, Miriam
    Schmidt, Bernhard
    Flohr, Thomas
    Reiser, Maximilian F.
    Becker, Christoph R.
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (06) : 1510 - 1517