Interference by cellular phones with permanent implanted pacemakers:: an update

被引:42
|
作者
Hekmat, K
Salemink, B
Lauterbach, G
Schwinger, RHG
Südkamp, M
Weber, HJ
Mehlhorn, U
机构
[1] Univ Cologne, Dept Cardiothorac Surg, D-50924 Cologne, Germany
[2] Univ Aachen, Dept Cardiovasc Engn Julich, Aachen, Germany
[3] Univ Cologne, Dept Cardiol, D-5000 Cologne 41, Germany
来源
EUROPACE | 2004年 / 6卷 / 04期
关键词
cellular telephones; interference; feedthru filter; pacemaker;
D O I
10.1016/j.eupc.2004.03.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The aim of this study was to test pacemakers with feedthru fitters for interference with a digital cellular telephone. Methods The study comprised 100 patients having their first pacemaker implantation between January 2001 and May 2003. A GSM-standard cellular phone was tested in the standby, dialing and operating mode against 23 single-chamber and 77 dual-chamber pacemakers. Continuous surface electrocardiograms, intracardiac electrograms, and marker channels were recorded when calls were made by a land phone to the cellular phone. Results In 2 patients we observed pacing inhibition with the cellular phone positioned directly above the pacemaker pocket. The unipolar and bipolar ventricular sensitivity setting was 0.25 mV in one dual-chamber pacemaker, and when we changed the sensitivity to 0.50 mV and higher no interference could be detected. The second inhibition occurred in a single-chamber pacemaker with unipolar and bipolar ventricular sensitivity setting of 0.5 mV, where a sensitivity change to 1.0 mV eliminated the interference. Conclusion Anticipating a correct setting of ventricular sensitivity, currently available pacemakers equipped with feedthru fitters do not show any interference with cellular phones. Since interference was only observed with sensitivity settings below 0.50 mV, we recommend that permanent programming of ventricular sensitivity should be set at 2.0 mV and higher. (C) 2004 The European Society of Cardiology. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:363 / 369
页数:7
相关论文
共 50 条
  • [21] Multiple leadless pacemakers implanted in the right ventricle of swine
    Chen, Keping
    Zheng, Xiaolin
    Dai, Yan
    Wang, Hao
    Tang, Yue
    Lan, Tingyu
    Zhang, Jinping
    Tian, Yi
    Zhang, Baojie
    Zhou, Xiaohong
    Bonner, Matthew
    Zhang, Shu
    EUROPACE, 2016, 18 (11): : 1748 - 1752
  • [22] The medical aspects of EMI effect on patients implanted with pacemakers
    Upadhyay, Sahil
    Upadhya, Ankita
    Salehi, Waleed
    Gupta, Gaurav
    MATERIALS TODAY-PROCEEDINGS, 2021, 45 : 5243 - 5248
  • [23] Interference of programmed electromagnetic stimulation with pacemakers and automatic implantable cardioverter defibrillators
    Gwechenberger, Marianne
    Rauscha, Friedrich
    Stix, Guenter
    Schmid, Gernot
    Strametz-Juranek, Jeanette
    BIOELECTROMAGNETICS, 2006, 27 (05) : 365 - 377
  • [24] SURGERY MANAGEMENT OF PATIENTS WITH IMPLANTED PACEMAKERS AND CARDIOVERTER DEFIBRILLATORS
    Kuchler, Darja Servicl
    Zupan, Igor
    Gersak, Borut
    ZDRAVNISKI VESTNIK-SLOVENIAN MEDICAL JOURNAL, 2009, 78 (04): : 175 - 179
  • [25] Electromagnetic Interference of Avalanche Transceivers with Cardiac Pacemakers and Implantable Cardioverter Defibrillators
    Dorenkamp, Marc
    Blaschke, Florian
    Voigt, Kathleen
    Fleck, Eckart
    Goetze, Stephan
    Roser, Mattias
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (08): : 931 - 938
  • [26] Epithermal neutron beam interference with cardiac pacemakers
    Koivunoro, H.
    Seren, T.
    Hyvonen, H.
    Kotiluoto, P.
    Iivonen, P.
    Auterinen, I.
    Seppala, T.
    Kankaanranta, L.
    Pakarinen, S.
    Tenhunen, M.
    Savolainen, S.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (12) : 1904 - 1906
  • [27] Computational Analysis of Induced Voltage on Implanted Cardiac Pacemaker's Lead by Mobile Phones
    Smondrk, Maros
    Benova, Mariana
    Psenakova, Zuzana
    INFORMATION TECHNOLOGY IN BIOMEDICINE (ITIB 2018), 2019, 762 : 325 - 336
  • [28] PHYSICAL REHABILITATION OF PATIENTS WITH PERMANENT CARDIAC-PACEMAKERS
    NIKITIN, YP
    MILLER, ON
    BONDAREVA, ZG
    MOSUNOV, AI
    KARDIOLOGIYA, 1994, 34 (9-10) : 5 - 8
  • [29] Permanent pacemakers: Should straightened atrial leads be repositioned?
    Hildick-Smith, DJR
    Satchithananda, DK
    Newell, SA
    Grace, AA
    Murgatroyd, FD
    Petch, MC
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (11): : 2142 - 2145
  • [30] Safety of the Wearable Cardioverter Defibrillator (WCD) in Patients with Implanted Pacemakers
    Schmitt, Joern
    Abaci, Guezine
    Johnson, Victoria
    Erkapic, Damir
    Gemein, Christopher
    Chasan, Ritvan
    Weipert, Kay
    Hamm, Christian W.
    Klein, Helmut U.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (03): : 271 - 277