Interference by cellular phones with permanent implanted pacemakers:: an update

被引:42
|
作者
Hekmat, K
Salemink, B
Lauterbach, G
Schwinger, RHG
Südkamp, M
Weber, HJ
Mehlhorn, U
机构
[1] Univ Cologne, Dept Cardiothorac Surg, D-50924 Cologne, Germany
[2] Univ Aachen, Dept Cardiovasc Engn Julich, Aachen, Germany
[3] Univ Cologne, Dept Cardiol, D-5000 Cologne 41, Germany
来源
EUROPACE | 2004年 / 6卷 / 04期
关键词
cellular telephones; interference; feedthru filter; pacemaker;
D O I
10.1016/j.eupc.2004.03.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The aim of this study was to test pacemakers with feedthru fitters for interference with a digital cellular telephone. Methods The study comprised 100 patients having their first pacemaker implantation between January 2001 and May 2003. A GSM-standard cellular phone was tested in the standby, dialing and operating mode against 23 single-chamber and 77 dual-chamber pacemakers. Continuous surface electrocardiograms, intracardiac electrograms, and marker channels were recorded when calls were made by a land phone to the cellular phone. Results In 2 patients we observed pacing inhibition with the cellular phone positioned directly above the pacemaker pocket. The unipolar and bipolar ventricular sensitivity setting was 0.25 mV in one dual-chamber pacemaker, and when we changed the sensitivity to 0.50 mV and higher no interference could be detected. The second inhibition occurred in a single-chamber pacemaker with unipolar and bipolar ventricular sensitivity setting of 0.5 mV, where a sensitivity change to 1.0 mV eliminated the interference. Conclusion Anticipating a correct setting of ventricular sensitivity, currently available pacemakers equipped with feedthru fitters do not show any interference with cellular phones. Since interference was only observed with sensitivity settings below 0.50 mV, we recommend that permanent programming of ventricular sensitivity should be set at 2.0 mV and higher. (C) 2004 The European Society of Cardiology. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:363 / 369
页数:7
相关论文
共 50 条
  • [1] Interference of cellular phones with implanted permanent pacemakers
    Chen, WH
    Lau, CP
    Leung, SK
    Ho, DSW
    Lee, ISF
    CLINICAL CARDIOLOGY, 1996, 19 (11) : 881 - 886
  • [2] Third-Generation Mobile Phones (UMTS) Do Not Interfere with Permanent Implanted Pacemakers
    Ismail, Mohamed M.
    Badreldin, Akmal M. A.
    Heldwein, Matthias
    Hekmat, Khosro
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (07): : 860 - 864
  • [3] Influence of digital and analogue cellular telephones on implanted pacemakers
    Altamura, G
    Toscano, S
    Gentilucci, G
    Ammirati, F
    Castro, A
    Pandozi, C
    Santini, M
    EUROPEAN HEART JOURNAL, 1997, 18 (10) : 1632 - 1641
  • [4] Induction ovens and electromagnetic interference: What is the risk for patients with implanted pacemakers?
    Rickli, H
    Facchini, M
    Brunner, H
    Ammann, P
    Sagmeister, M
    Klaus, G
    Angehrn, W
    Luechinger, R
    Duru, F
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (07): : 1494 - 1497
  • [5] Evaluation of electromagnetic interference of GSM mobile phones with pacemakers featuring remote monitoring functions
    Calcagnini, G
    Censi, F
    Floris, M
    Pignalberi, C
    Ricci, R
    Biancalana, G
    Bartolini, P
    Santini, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (04): : 380 - 385
  • [6] Influence of body worn wireless mobile devices on implanted cardiac pacemakers
    Seitz, Sebastian
    Doessel, Olaf
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 2632 - 2635
  • [7] In vitro and in vivo evaluation of electromagnetic interference between wireless home monitoring pacemakers and GSM mobile phones
    Barbaro, V
    Bartolini, P
    Calcagnini, G
    Censi, F
    Floris, M
    Pignalberi, C
    Ricci, R
    Santini, M
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3602 - 3605
  • [8] An Update on Pacemakers and Defibrillators
    Walker, T. Jennifer
    JNP-JOURNAL FOR NURSE PRACTITIONERS, 2019, 15 (01): : 26 - +
  • [9] Perioperative management of patients with implanted pacemakers or cardioverter/defibrillators
    Gombotz, H.
    Monti, M. Anelli
    Leitgeb, N.
    Nuernberg, M.
    Strohmer, B.
    ANAESTHESIST, 2009, 58 (05): : 485 - 498
  • [10] Permanent pacemakers in older persons
    Gregoratos, G