Impact of tip-apex distance and femoral head lag screw position on treatment outcomes of unstable intertrochanteric fractures using cephalomedullary nails

被引:15
作者
Lee, Cheng-Hung [1 ,2 ]
Su, Kuo-Chih [3 ,4 ]
Chen, Kun-Hui [1 ,3 ]
Pan, Chien-Chou [1 ]
Wu, Yun-Che [1 ]
机构
[1] Taichung Vet Gen Hosp, Dept Orthoped, 1650 Taiwan Blvd Sect 4, Taichung 40705, Taiwan
[2] Hungkuang Univ, Dept Appl Cosmetol, Taichung, Taiwan
[3] Hungkuang Univ, Dept Biomed Engn, Taichung, Taiwan
[4] Taichung Vet Gen Hosp, Dept Med Res, Taichung, Taiwan
关键词
Biomechanics; finite element analysis; cephalomedullary nail; tip-apex distance; unstable intertrochanteric fracture; lag screw; BIOMECHANICAL ANALYSIS; GAMMA-NAIL; FINITE-ELEMENT; HIP SCREW; FIXATION; IMPLANTATION; FAILURE; PLATE;
D O I
10.1177/0300060518775835
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background Cephalomedullary nails are frequently used in unstable intertrochanteric fractures. The implant position is an important factor for surgical success. Thus, in the present study, finite element analysis methods were used to investigate the biomechanical behavior of five different cephalomedullary nail positions in unstable intertrochanteric fractures. Methods Five different cephalomedullary nail implant positions were investigated. The observed indicators were the maximum displacement of the lag screw, the stress on the intertrochanteric fracture with involvement of the posteromedial cortex, and the tip-apex distance. Results The smallest lag screw displacement was achieved when the implant was closer to the inferior femoral head. Lower stress was placed on the posteromedial cortex when the implant was positioned closer to the inferior femoral head. However, the tip-apex distance increased when the lag screw was positioned more inferiorly. Conclusions The results of this study suggest that positioning the lag screw closer to the inferior aspect of the femoral head can reduce stress on the posteromedial cortex and deformation of the implant in unstable intertrochanteric fractures. These findings provide a biomechanical basis for selection of the cephalomedullary nail implantation site. Level of evidence III.
引用
收藏
页码:2128 / 2140
页数:13
相关论文
共 24 条
  • [1] Inadequate 'three-point' proximal fixation predicts failure of the Gamma nail
    Abram, S. G. F.
    Pollard, T. C. B.
    Andrade, A. J. M. D.
    [J]. BONE & JOINT JOURNAL, 2013, 95B (06) : 825 - 830
  • [2] Treatment of recent trochanteric fracture in adults
    Adam, P.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (01) : S75 - S83
  • [3] Tip apex distance, hip screw placement, and neck shaft angle as potential risk factors for cut-out failure of hip screws after surgical treatment of intertrochanteric fractures
    Andruszkow, Hagen
    Frink, Michael
    Froemke, Cornelia
    Matityahu, Amir
    Zeckey, Christian
    Mommsen, Philipp
    Suntardjo, Stefanie
    Krettek, Christian
    Hildebrand, Frank
    [J]. INTERNATIONAL ORTHOPAEDICS, 2012, 36 (11) : 2347 - 2354
  • [4] The importance of intramedullary hip nail positioning during implantation for stable pertrochanteric fractures: biomechanical analysis
    Bartoska, Radek
    Baca, Vaclav
    Horak, Zdenek
    Hrubina, Maros
    Skala-Rosenbaum, Jiri
    Marvan, Jiri
    Kachlik, David
    Dzupa, Valer
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 2016, 38 (05) : 577 - 585
  • [5] THE VALUE OF THE TIP-APEX DISTANCE IN PREDICTING FAILURE OF FIXATION OF PERITROCHANTERIC FRACTURES OF THE HIP
    BAUMGAERTNER, MR
    CURTIN, SL
    LINDSKOG, DM
    KEGGI, JM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (07) : 1058 - 1064
  • [6] Critical factors in cut-out complication after gamma nail treatment of proximal femoral fractures
    Bojan, Alicja J.
    Beimel, Claudia
    Taglang, Gilbert
    Collin, David
    Ekholm, Carl
    Jonsson, Anders
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [7] Osteoporotic Hip Fractures: The Burden of Fixation Failure
    Broderick, J. M.
    Bruce-Brand, R.
    Stanley, E.
    Mulhall, K. J.
    [J]. SCIENTIFIC WORLD JOURNAL, 2013,
  • [8] The importance of lag screw position for the stabilization of trochanteric fractures with a sliding hip screw: A subject-specific finite element study
    Goffin, Jerome M.
    Pankaj, Pankaj
    Simpson, A. Hamish
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (04) : 596 - 600
  • [9] Haidukewych GJ, 2009, J BONE JOINT SURG AM, V91A, P712
  • [10] Heckman J.D., 2015, Rockwood and green's fractures in adults