High-Rate Hydrogen Separation Using an MIEC Oxygen Permeable Membrane Reactor

被引:35
|
作者
Li, Wenping [1 ,2 ]
Cao, Zhongwei [1 ]
Zhu, Xuefeng [1 ]
Yang, Weishen [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, State Key Lab Catalysis, Dalian 116023, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
hydrogen separation; MIEC membrane reactor; water splitting; high-purity hydrogen; oxygen permeation; DUAL-PHASE MEMBRANES; PARTIAL OXIDATION; PD; STABILITY; GAS; METHANE; SYSTEM; PURITY;
D O I
10.1002/aic.15502
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this study, we propose using mixed ionic-electronic conducting (MIEC) oxygen permeable membrane to separate hydrogen via the water splitting reaction. To do that, steam was fed to one side of the membrane (side I) and a lowpurity hydrogen was fed to the other side (side II). Oxygen from water splitting on side I permeates through the membrane driven by an oxygen chemical potential gradient across the membrane to react with the low-purity hydrogen on side II. After condensation and drying, high-purity hydrogen is acquired from side I. Thus, the hydrogen separation process is realized based on the fact that the low-purity hydrogen is consumed and high-purity hydrogen is acquired. We achieved a high hydrogen separation rate (13.5 mL cm(-2) min(-1)) at 950 degrees C in a reactor equipped with a 0.5-mm-thick Ba0.98Ce0.05Fe0.95O3-delta membrane. This research proofed that it is feasible to upgrade hydrogen purity using an MIEC oxygen permeable membrane. (C) 2016 American Institute of Chemical Engineers AIChE J, 63: 1278-1286, 2017
引用
收藏
页码:1278 / 1286
页数:9
相关论文
共 50 条
  • [21] Highly efficient and stable hydrogen permeable membrane reactor for propane dehydrogenation
    Gan, Zhixu
    Dewangan, Nikita
    Wang, Zhigang
    Liu, Shaomin
    Tan, Xiaoyao
    Kawi, Sibudjing
    JOURNAL OF MEMBRANE SCIENCE, 2024, 701
  • [22] Methane Steam Reforming in Hydrogen-permeable Membrane Reactor for Pure Hydrogen Production
    Matsumura, Yasuyuki
    Tong, Jianhua
    TOPICS IN CATALYSIS, 2008, 51 (1-4) : 123 - 132
  • [23] Methane Steam Reforming in Hydrogen-permeable Membrane Reactor for Pure Hydrogen Production
    Yasuyuki Matsumura
    Jianhua Tong
    Topics in Catalysis, 2008, 51 : 123 - 132
  • [24] Pure hydrogen production by methane steam reforming with hydrogen-permeable membrane reactor
    Tong, H
    Matsumura, Y
    CATALYSIS TODAY, 2006, 111 (3-4) : 147 - 152
  • [25] Reactor configuration and concentration polarization in methane steam reforming by a membrane reactor with a highly hydrogen-permeable membrane
    Mori, Nobuhiko
    Nakamura, Toshiyuki
    Noda, Ken-ichi
    Sakai, Osamu
    Takahashi, Akira
    Ogawa, Naoyuki
    Sakai, Hitoshi
    Iwamoto, Yuji
    Hattori, Tadashi
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2007, 46 (07) : 1952 - 1958
  • [26] Performance of high-rate denitrifying compartmentalized anoxic reactor
    Li, Wei
    Zheng, Ping
    Xie, Zuofu
    Zhang, Meng
    Song, Ji
    Huang, Shenmin
    Lian, Guoqiang
    Zheng, P. (pzheng@zju.edu.cn), 1600, Materials China (64): : 1276 - 1282
  • [27] SELECTION OF CONTROLLED VARIABLES FOR A HIGH-RATE ANAEROBIC REACTOR
    DENAC, M
    GRIFFIN, K
    LEE, PL
    GREENFIELD, PF
    ENVIRONMENTAL TECHNOLOGY LETTERS, 1988, 9 (10): : 1029 - 1040
  • [28] HIGH-RATE PHOTORESIST STRIPPING IN AN OXYGEN AFTERGLOW
    SPENCER, JE
    BOREL, RA
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1986, 133 (09) : 1922 - 1925
  • [29] Research and development of a new high-rate anaerobic reactor
    Wang, Shu-Ying
    Wang, Xiao-Lian
    Li, Tan-Wei
    Beijing Gongye Daxue Xuebao / Journal of Beijing University of Technology, 2005, 31 (06): : 608 - 612
  • [30] Improving oxygen permeation of MIEC membrane reactor by enhancing the electronic conductivity under intermediate-low oxygen partial pressures
    Cai, Lili
    Li, Wenping
    Cao, Zhongwei
    Zhu, Xuefeng
    Yang, Weishen
    JOURNAL OF MEMBRANE SCIENCE, 2016, 520 : 607 - 615