Reproducibility of three-dimensional gel installation sonohysterography in the assessment and classification of intrauterine abnormalities

被引:3
作者
Nieuwenhuis, Lotte L. [1 ]
de Vaate, Marjolein A. J. Bij [1 ]
Hehenkamp, Wouter J. K. [1 ]
Heymans, Martijn W. [2 ]
van Baal, Marchien W. M. [3 ]
Brolmann, Hans A. M. [1 ]
Huirne, Judith A. F. [1 ]
机构
[1] VU Med Ctr VUmc, Dept Obstet & Gynaecol, Amsterdam, Netherlands
[2] VU Med Ctr VUmc, Dept Epidemiol & Biostat, Amsterdam, Netherlands
[3] Flevoziekenhuis, Dept Obstet & Gynaecol, Almere, Netherlands
关键词
Saline or gel infusion; Sonohysterography; Three dimensional; Reproducibility; Intrauterine abnormalities; SALINE CONTRAST SONOHYSTEROGRAPHY; HYSTEROSCOPIC MYOMECTOMY; DIAGNOSTIC HYSTEROSCOPY; SUBMUCOUS FIBROIDS; CLINICAL-VALUE; AGREEMENT; WOMEN; HYSTEROSONOGRAPHY; SONOGRAPHY;
D O I
10.1016/j.ejogrb.2014.05.010
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: Purpose of this study is to determine the interobserver and intraobserver variability of 3D GIS in the assessment of intrauterine abnormalities. Study design: Forty five 3D volumes were randomly selected from a larger prospective cohort study that studied the diagnostic accuracy of 3D GIS in addition to 2D GIS. To study interobserver agreement volumes were reviewed by two independent examiners. One examiner reviewed these samples twice with an interval of 1 month in a random order. Interobserver and intraobserver agreement were tested with Cohen's kappa coefficient and shown in Bland and Altman plots. Quality of the 3D volumes was evaluated. Results: Cohen's kappa for interobserver variability for type of abnormalities (none, polyp, fibroid, other) was 0.64 and for presence of a fibroid (fibroid yes/no) 0.77. Agreement on type of fibroid was 0.59. Intraobserver agreement was almost perfect for type of abnormality (Cohen's kappa of 1.0) and good for fibroid diameter. Quality of the 3D volumes was poor in 11 out of 45 cases. Reproducibility increased when poor quality images were excluded. Conclusion: Substantial interobserver and intraobserver agreement for 3D GIS in the diagnoses of intrauterine abnormalities was found. 3D GIS interobserver and intraobserver agreement are good for fibroid diameter and moderate for volume and protrusion. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
[41]   Reproducibility of transvaginal three-dimensional endometrial volume measurements during ovarian stimulation [J].
Yaman, C ;
Sommergruber, M ;
Ebner, T ;
Pölz, W ;
Moser, M ;
Tews, G .
HUMAN REPRODUCTION, 1999, 14 (10) :2604-2608
[42]   Three-dimensional hysterosonography versus hysteroscopy for the detection of intracavitary uterine abnormalities [J].
Makris, N. ;
Kalmantis, K. ;
Skartados, N. ;
Papadimitriou, A. ;
Mantzaris, G. ;
Antsaklis, A. .
INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2007, 97 (01) :6-9
[43]   Three-dimensional computed tomographic imaging of complex congenital cardiovascular abnormalities [J].
Bean, MJ ;
Pannu, H ;
Fishman, EK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (06) :721-724
[44]   Three-dimensional ultrasound assessment of fetal liver volume in normal pregnancy: A comparison of reproducibility with two-dimensional ultrasound and a search for a volume constant [J].
Chang, FM ;
Hsu, KF ;
Ko, HC ;
Yao, BL ;
Chang, CH ;
Yu, CH ;
Chen, HY .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (03) :381-389
[45]   Measuring the Angle of the Subpubic Arch Using Three-Dimensional Transperineal Ultrasound Scan: Intraoperator Repeatability and Interoperator Reproducibility [J].
Choi, Sarah ;
Chan, Symphorosa Shing Chee ;
Sahota, Daljit Singh ;
Leung, Tak Yeung .
AMERICAN JOURNAL OF PERINATOLOGY, 2013, 30 (03) :191-195
[46]   Three-dimensional sonographic morphologic assessment in complex adnexal masses -: Preliminary experience [J].
Alcázar, JL ;
Galán, MJ ;
Garcia-Manero, M ;
Guerriero, S .
JOURNAL OF ULTRASOUND IN MEDICINE, 2003, 22 (03) :249-254
[47]   Evaluation of a novel portable three-dimensional scapular kinematics assessment system with inter and intraobserver reproducibility and normative data for healthy adults [J].
Miguel Angel Ruiz Ibán ;
Andrea Paniagua Gonzalez ;
Marco Muraccini ;
Cristina Asenjo Gismero ;
Alessandro Varini ;
Antonella Berardi ;
Matteo Mantovani .
Journal of Experimental Orthopaedics, 7
[48]   Feasibility and Reproducibility of Left Atrium Measurements Using Different Three-Dimensional Echocardiographic Modalities [J].
Motoc, Andreea ;
Roosens, Bram ;
Scheirlynck, Esther ;
Tanaka, Kaoru ;
Luchian, Maria Luiza ;
Magne, Julien ;
Mandoli, Giulia Elena ;
Hinojar, Rocio ;
Cameli, Matteo ;
Zamorano, Jose Luis ;
Droogmans, Steven ;
Cosyns, Bernard .
DIAGNOSTICS, 2020, 10 (12)
[49]   Accuracy and reproducibility of the DAVID SLS-2 scanner in three-dimensional facial imaging [J].
Secher, Jesper Jared ;
Darvann, Tron Andre ;
Pinholt, Else Marie .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (10) :1662-1670
[50]   Three-dimensional reconstruction using stereoradiography for evaluating adult spinal deformity: a reproducibility study [J].
Ferrero, Emmanuelle ;
Lafage, Renaud ;
Vira, Shaleen ;
Rohan, Pierre-Yves ;
Oren, Jonathan ;
Delsole, Edward ;
Guigui, Pierre ;
Schwab, Frank ;
Lafage, Virginie ;
Skalli, Wafa .
EUROPEAN SPINE JOURNAL, 2017, 26 (08) :2112-2120