Reproducibility of three-dimensional gel installation sonohysterography in the assessment and classification of intrauterine abnormalities

被引:3
作者
Nieuwenhuis, Lotte L. [1 ]
de Vaate, Marjolein A. J. Bij [1 ]
Hehenkamp, Wouter J. K. [1 ]
Heymans, Martijn W. [2 ]
van Baal, Marchien W. M. [3 ]
Brolmann, Hans A. M. [1 ]
Huirne, Judith A. F. [1 ]
机构
[1] VU Med Ctr VUmc, Dept Obstet & Gynaecol, Amsterdam, Netherlands
[2] VU Med Ctr VUmc, Dept Epidemiol & Biostat, Amsterdam, Netherlands
[3] Flevoziekenhuis, Dept Obstet & Gynaecol, Almere, Netherlands
关键词
Saline or gel infusion; Sonohysterography; Three dimensional; Reproducibility; Intrauterine abnormalities; SALINE CONTRAST SONOHYSTEROGRAPHY; HYSTEROSCOPIC MYOMECTOMY; DIAGNOSTIC HYSTEROSCOPY; SUBMUCOUS FIBROIDS; CLINICAL-VALUE; AGREEMENT; WOMEN; HYSTEROSONOGRAPHY; SONOGRAPHY;
D O I
10.1016/j.ejogrb.2014.05.010
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: Purpose of this study is to determine the interobserver and intraobserver variability of 3D GIS in the assessment of intrauterine abnormalities. Study design: Forty five 3D volumes were randomly selected from a larger prospective cohort study that studied the diagnostic accuracy of 3D GIS in addition to 2D GIS. To study interobserver agreement volumes were reviewed by two independent examiners. One examiner reviewed these samples twice with an interval of 1 month in a random order. Interobserver and intraobserver agreement were tested with Cohen's kappa coefficient and shown in Bland and Altman plots. Quality of the 3D volumes was evaluated. Results: Cohen's kappa for interobserver variability for type of abnormalities (none, polyp, fibroid, other) was 0.64 and for presence of a fibroid (fibroid yes/no) 0.77. Agreement on type of fibroid was 0.59. Intraobserver agreement was almost perfect for type of abnormality (Cohen's kappa of 1.0) and good for fibroid diameter. Quality of the 3D volumes was poor in 11 out of 45 cases. Reproducibility increased when poor quality images were excluded. Conclusion: Substantial interobserver and intraobserver agreement for 3D GIS in the diagnoses of intrauterine abnormalities was found. 3D GIS interobserver and intraobserver agreement are good for fibroid diameter and moderate for volume and protrusion. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
  • [31] Three-dimensional CT Improves the Reproducibility of Stability Evaluation for Intertrochanteric Fractures
    Cho, Yi-cheng
    Lee, Pei-yuan
    Lee, Cheng-hung
    Chen, Chih-hui
    Lin, Yu-min
    ORTHOPAEDIC SURGERY, 2018, 10 (03) : 212 - 217
  • [32] Transvaginal three-dimensional ultrasound: Reproducibility of ovarian and endometrial volume measurements
    KyeiMensah, A
    Pittrof, R
    Maconochie, N
    Campbell, S
    Zaidi, J
    Tan, SL
    FERTILITY AND STERILITY, 1996, 66 (05) : 718 - 722
  • [33] Intra- and Interobserver Reproducibility of Left Ventricular Mechanical Dyssynchrony Assessment by Real Time Three-Dimensional Echocardiography
    Russo, Cesare
    Jaubert, Marie-Perrine
    Jin, Zhezhen
    Homma, Shunichi
    Di Tullio, Marco R.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (05): : 598 - 607
  • [34] Three-Dimensional Dynamic Analysis of the Reproducibility of Verbal and Nonverbal Facial Expressions
    Qiu, Tiancheng
    Xue, Zulin
    Wu, Ling
    Yang, Rong
    Liu, Xiaojing
    Wang, Xing
    Li, Zili
    CLEFT PALATE-CRANIOFACIAL JOURNAL, 2022, 59 (01) : 22 - 31
  • [35] Reproducibility, Accuracy and Effect of Autoclave Sterilization on a Thermoplastic Three-Dimensional Model Printed by a Desktop Fused Deposition Modelling Three-Dimensional Printer
    Boursier, Jean-Francois
    Fournet, Alexandre
    Bassanino, Jean
    Manassero, Mathieu
    Bedu, Anne-Sophie
    Leperlier, Dimitri
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2018, 31 (06) : 422 - 430
  • [36] Reproducibility of three-dimensional power Doppler placental vascular indices in pregnancies between 26 and 35 weeks
    Guimaraes Filho, Helio Antonio
    Mattar, Rosiane
    Araujo Junior, Edward
    Dias da Costa, Lavoisier Linhares
    de Mello Junior, Carlos Fernando
    Machado Nardozza, Luciano Marcondes
    Nowak, Paulo Martin
    Moron, Antonio Fernandes
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2011, 283 (02) : 213 - 217
  • [37] Three-dimensional measurement method of arthritic glenoid cavity morphology: Feasibility and reproducibility
    Moineau, G.
    Levigne, C.
    Boileau, P.
    Young, A.
    Walch, G.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (06) : S139 - S145
  • [38] Validation and reproducibility of a high-resolution three-dimensional facial imaging system
    Kharnbay, B.
    Nairn, N.
    Bell, A.
    Miller, J.
    Bowman, A.
    Ayoub, A. F.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2008, 46 (01) : 27 - 32
  • [39] Reproducibility of three-dimensional ultrasound endometrial volume measurements in patients with postmenopausal bleeding
    Yaman, C
    Ebner, T
    Jesacher, K
    Obermayr, G
    Pölz, W
    Tews, G
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2002, 19 (03) : 282 - 286
  • [40] Reproducibility of fetal renal pelvis volume measurement using three-dimensional ultrasound
    Duin, L. K.
    Willekes, C.
    Vossen, M.
    Beckers, M.
    Offermans, J.
    Nijhuis, J. G.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (06) : 657 - 661