Reproducibility of three-dimensional gel installation sonohysterography in the assessment and classification of intrauterine abnormalities

被引:3
|
作者
Nieuwenhuis, Lotte L. [1 ]
de Vaate, Marjolein A. J. Bij [1 ]
Hehenkamp, Wouter J. K. [1 ]
Heymans, Martijn W. [2 ]
van Baal, Marchien W. M. [3 ]
Brolmann, Hans A. M. [1 ]
Huirne, Judith A. F. [1 ]
机构
[1] VU Med Ctr VUmc, Dept Obstet & Gynaecol, Amsterdam, Netherlands
[2] VU Med Ctr VUmc, Dept Epidemiol & Biostat, Amsterdam, Netherlands
[3] Flevoziekenhuis, Dept Obstet & Gynaecol, Almere, Netherlands
关键词
Saline or gel infusion; Sonohysterography; Three dimensional; Reproducibility; Intrauterine abnormalities; SALINE CONTRAST SONOHYSTEROGRAPHY; HYSTEROSCOPIC MYOMECTOMY; DIAGNOSTIC HYSTEROSCOPY; SUBMUCOUS FIBROIDS; CLINICAL-VALUE; AGREEMENT; WOMEN; HYSTEROSONOGRAPHY; SONOGRAPHY;
D O I
10.1016/j.ejogrb.2014.05.010
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: Purpose of this study is to determine the interobserver and intraobserver variability of 3D GIS in the assessment of intrauterine abnormalities. Study design: Forty five 3D volumes were randomly selected from a larger prospective cohort study that studied the diagnostic accuracy of 3D GIS in addition to 2D GIS. To study interobserver agreement volumes were reviewed by two independent examiners. One examiner reviewed these samples twice with an interval of 1 month in a random order. Interobserver and intraobserver agreement were tested with Cohen's kappa coefficient and shown in Bland and Altman plots. Quality of the 3D volumes was evaluated. Results: Cohen's kappa for interobserver variability for type of abnormalities (none, polyp, fibroid, other) was 0.64 and for presence of a fibroid (fibroid yes/no) 0.77. Agreement on type of fibroid was 0.59. Intraobserver agreement was almost perfect for type of abnormality (Cohen's kappa of 1.0) and good for fibroid diameter. Quality of the 3D volumes was poor in 11 out of 45 cases. Reproducibility increased when poor quality images were excluded. Conclusion: Substantial interobserver and intraobserver agreement for 3D GIS in the diagnoses of intrauterine abnormalities was found. 3D GIS interobserver and intraobserver agreement are good for fibroid diameter and moderate for volume and protrusion. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
  • [21] Reproducibility of asymmetry measurements of the mandible in three-dimensional CT imaging
    Kim, Go-Woon
    Kim, Jae-Hyung
    Lee, Ki-Heon
    Hwang, Hyeon-Shik
    KOREAN JOURNAL OF ORTHODONTICS, 2008, 38 (05) : 314 - 327
  • [22] Evaluation of a novel portable three-dimensional scapular kinematics assessment system with inter and intraobserver reproducibility and normative data for healthy adults
    Ruiz Iban, Miguel Angel
    Paniagua Gonzalez, Andrea
    Muraccini, Marco
    Asenjo Gismero, Cristina
    Varini, Alessandro
    Berardi, Antonella
    Mantovani, Matteo
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2020, 7 (01)
  • [23] The Role of Three-Dimensional Imaging in the Control of Intrauterine Contraceptive Devices
    Ahmadi, Firoozeh
    Haghighi, Hadieh
    IRANIAN JOURNAL OF RADIOLOGY, 2015, 12 (02)
  • [24] Three-dimensional ultrasound and three-dimensional power Doppler in the assessment of ovarian tumors
    Laban, M.
    Metawee, H.
    Elyan, A.
    Kamal, M.
    Kamel, M.
    Mansour, G.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2007, 99 (03) : 201 - 205
  • [25] Reproducibility of osseous landmarks used for computed tomography based three-dimensional cephalometric analyses
    Olszewski, Raphael
    Tanesy, Olivier
    Cosnard, Guy
    Zech, Francis
    Reychler, Herve
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2010, 38 (03) : 214 - 221
  • [26] Diagnostic value of three-dimensional saline infusion sonohysterography in the evaluation of the uterus and uterine cavity lesions
    Sabry, Ahmed S. A.
    Fadl, Shimaa A.
    Szmigielski, Wojciech
    Alobaidely, Amal
    Ahmed, Sanaa S. H.
    Sherif, Hanan
    Yousef, Reda R. H.
    Mahfouz, Ahmed
    POLISH JOURNAL OF RADIOLOGY, 2018, 83 : E482 - E490
  • [27] Reproducibility and reliability of three-dimensional soft tissue landmark identification using three- dimensional stereophotogrammetry
    Baysal, Asli
    Sahan, Ahmet Oguz
    Ozturk, Mehmet Ali
    Uysal, Tancan
    ANGLE ORTHODONTIST, 2016, 86 (06) : 1004 - 1009
  • [28] Three-Dimensional Saline Contrast Sonohysterography in Detecting Uterine Anomalies and Pathologies Among Subfertile Women and Women with Abnormal Uterine Bleeding
    Khan, Faryal A.
    Al Fayyad, Isamme
    Al-Tannir, Mohamad
    Hansoti, Shehnaz
    Ali, Roua
    Al-Jaroudi, Dania
    JOURNAL OF REPRODUCTIVE MEDICINE, 2019, 64 (9-10) : 364 - 370
  • [29] Correlation between three dimensional multi-slice sonohysterography and hysteroscopy in the diagnosis and classification of submucous myomas
    Negm, Sherif M. M.
    Kamel, Rasha A.
    Momtaz, Mohamad
    Magdi, Ahmed M.
    Azab, Hamdy S.
    MIDDLE EAST FERTILITY SOCIETY JOURNAL, 2010, 15 (03) : 209 - 215
  • [30] Three-dimensional motion analysis - an exploratory study. Part 2: Reproducibility of facial movement
    Popat, H.
    Richmond, S.
    Playle, R.
    Marshall, D.
    Rosin, P. L.
    Cosker, D.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2008, 11 (04) : 224 - 228