Reproducibility of three-dimensional gel installation sonohysterography in the assessment and classification of intrauterine abnormalities

被引:3
|
作者
Nieuwenhuis, Lotte L. [1 ]
de Vaate, Marjolein A. J. Bij [1 ]
Hehenkamp, Wouter J. K. [1 ]
Heymans, Martijn W. [2 ]
van Baal, Marchien W. M. [3 ]
Brolmann, Hans A. M. [1 ]
Huirne, Judith A. F. [1 ]
机构
[1] VU Med Ctr VUmc, Dept Obstet & Gynaecol, Amsterdam, Netherlands
[2] VU Med Ctr VUmc, Dept Epidemiol & Biostat, Amsterdam, Netherlands
[3] Flevoziekenhuis, Dept Obstet & Gynaecol, Almere, Netherlands
关键词
Saline or gel infusion; Sonohysterography; Three dimensional; Reproducibility; Intrauterine abnormalities; SALINE CONTRAST SONOHYSTEROGRAPHY; HYSTEROSCOPIC MYOMECTOMY; DIAGNOSTIC HYSTEROSCOPY; SUBMUCOUS FIBROIDS; CLINICAL-VALUE; AGREEMENT; WOMEN; HYSTEROSONOGRAPHY; SONOGRAPHY;
D O I
10.1016/j.ejogrb.2014.05.010
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: Purpose of this study is to determine the interobserver and intraobserver variability of 3D GIS in the assessment of intrauterine abnormalities. Study design: Forty five 3D volumes were randomly selected from a larger prospective cohort study that studied the diagnostic accuracy of 3D GIS in addition to 2D GIS. To study interobserver agreement volumes were reviewed by two independent examiners. One examiner reviewed these samples twice with an interval of 1 month in a random order. Interobserver and intraobserver agreement were tested with Cohen's kappa coefficient and shown in Bland and Altman plots. Quality of the 3D volumes was evaluated. Results: Cohen's kappa for interobserver variability for type of abnormalities (none, polyp, fibroid, other) was 0.64 and for presence of a fibroid (fibroid yes/no) 0.77. Agreement on type of fibroid was 0.59. Intraobserver agreement was almost perfect for type of abnormality (Cohen's kappa of 1.0) and good for fibroid diameter. Quality of the 3D volumes was poor in 11 out of 45 cases. Reproducibility increased when poor quality images were excluded. Conclusion: Substantial interobserver and intraobserver agreement for 3D GIS in the diagnoses of intrauterine abnormalities was found. 3D GIS interobserver and intraobserver agreement are good for fibroid diameter and moderate for volume and protrusion. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
  • [1] Diagnostic and clinical value of 3D gel installation sonohysterography in addition to 2D gel installation sonohysterography in the assessment of intrauterine abnormalities
    Nieuwenhuis, Lotte L.
    de Vaate, Marjolein Bij
    Hehenkamp, Wouter J. K.
    Heymans, Martijn W.
    van Baal, Marchien
    Brolmann, Hans A. M.
    Huirne, Judith A. F.
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2014, 175 : 67 - 74
  • [2] Evaluation of Intrauterine Structural Pathology by Three-Dimensional Sonohysterography Using An Extended Imaging Method
    Zafarani, Fatemeh
    Ahmadi, Firoozeh
    INTERNATIONAL JOURNAL OF FERTILITY & STERILITY, 2013, 7 (01) : 1 - 6
  • [3] Preoperative assessment of submucous fibroids by three-dimensional saline contrast sonohysterography
    Mavrelos, D.
    Naftalin, J.
    Hoo, W.
    Ben-Nagi, J.
    Holland, T.
    Jurkovic, D.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2011, 38 (03) : 350 - 354
  • [4] Reproducibility of the measurement of submucous fibroid protrusion into the uterine cavity using three-dimensional saline contrast sonohysterography
    Lee, C.
    Salim, R.
    Ofili-Yebovi, D.
    Yazbek, J.
    Davies, A.
    Jurkovic, D.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 28 (06) : 837 - 841
  • [5] Three-Dimensional Sonohysterography Compared With Vaginoscopic Hysteroscopy for Evaluation of the Uterine Cavity in Patients With Recurrent Implantation Failure in In Vitro Fertilization Cycles
    Negm, Sherif M. M.
    Kamel, Rasha A.
    Abuhamila, Fouad A.
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2012, 19 (04) : 503 - 508
  • [6] The Diagnostic Accuracy of Two- vs Three-Dimensional Sonohysterography for Evaluation of the Uterine Cavity in the Reproductive Age
    El-Sherbiny, Walid
    El-Mazny, Akmal
    Abou-Salem, Nermeen
    Mostafa, Wael Sayed
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2015, 22 (01) : 127 - 131
  • [7] A prospective study to evaluate the efficacy of two- and three-dimensional sonohysterography in women with intrauterine lesions
    Sylvestre, C
    Child, TJ
    Tulandi, T
    Tan, SL
    FERTILITY AND STERILITY, 2003, 79 (05) : 1222 - 1225
  • [8] A comparative study of three-dimensional saline infusion sonohysterography and diagnostic hysteroscopy for the classification of submucous fibroids
    Salim, R
    Lee, C
    Davies, A
    Jolaoso, B
    Ofuasia, E
    Jurkovic, D
    HUMAN REPRODUCTION, 2005, 20 (01) : 253 - 257
  • [9] Three-dimensional multiplanar sonohysterography - Comparison with conventional two-dimensional sonohysterography and X-ray hysterosalpingography
    Lev-Toaff, AS
    Pinheiro, LW
    Bega, G
    Kurtz, AB
    Goldberg, BB
    JOURNAL OF ULTRASOUND IN MEDICINE, 2001, 20 (04) : 295 - 306
  • [10] Three-dimensional saline-infusion sonohysterography is useful for the identification of endometrial polyp
    Inoue, Tsuneo
    Kitajima, Michio
    Taniguchi, Ken
    Masuzaki, Hideaki
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2016, 42 (07) : 855 - 859