Quantification of Cerebral Blood Flow in Healthy Volunteers and Type 1 Diabetic Patients: Comparison of MRI Arterial Spin Labeling and [15O]H2O Positron Emission Tomography (PET)

被引:27
|
作者
van Golen, Larissa W. [1 ]
Kuijer, Joost P. A. [2 ]
Huisman, Marc C. [3 ]
IJzerman, Richard G. [1 ]
Barkhof, Frederik [3 ]
Diamant, Michaela [1 ]
Lammertsma, Adriaan A. [3 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Internal Med, Ctr Diabet, NL-1081 HV Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Dept Phys & Med Technol, NL-1081 HV Amsterdam, Netherlands
[3] Vrije Univ Amsterdam Med Ctr, Dept Radiol & Nucl Med, NL-1081 HV Amsterdam, Netherlands
关键词
arterial spin labeling (ASL); cerebral blood flow (CBF); diabetes; O-15]H2O positron emission tomography (PET); GLUCOSE-METABOLISM; GENDER-DIFFERENCES; TC-99M-HMPAO SPET; HIGH-RESOLUTION; INSULIN; PERFUSION; O-15-WATER;
D O I
10.1002/jmri.24484
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare cerebral blood flow (CBF) values measured using magnetic resonance imaging (MRI) arterial spin labeling (ASL) with those obtained with [O-15]H2O positron emission tomography (PET), the gold standard for measuring CBF in vivo. Materials and Methods: Data were collected in 11 healthy men and in 20 age- and body mass index (BMI)-matched type 1 diabetic men. Pseudo-continuous ASL (PCASL) data were acquired at 3 T and [O-15]H2O PET scans were acquired using a high-resolution PET scanner. Input functions were obtained using on-line arterial blood sampling. Whole brain and regional CBF values were compared. Results: For both modalities, whole brain CBF was similar in both subject groups. In groups combined, average whole brain CBF was 0.30 0.05 mL center dot cm(-3)center dot min(-1) for [O-15]H2O PET and 0.34 +/- 0.05 mL center dot cm(-3)center dot min(-1) for ASL MRI (P < 0.01). A significant correlation between methods was observed for whole brain, gray and white matter. In 12 out of 33 brain regions a significant difference between methods was observed. Conclusion: PCASL provides CBF values that correlate with [O-15]H2O PET-derived values, but is less accurate. PCASL may be an attractive alternative when absolute quantification is not needed.J. Magn. Reson. Imaging 2014;40:1300-1309. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1300 / 1309
页数:10
相关论文
共 20 条
  • [1] Comparison of velocity- and acceleration-selective arterial spin labeling with [15O]H2O positron emission tomography
    Schmid, Sophie
    Heijtel, Dennis F. R.
    Mutsaerts, Henri J. M. M.
    Boellaard, Ronald
    Lammertsma, Adriaan A.
    Nederveen, Aart J.
    van Osch, Matthias J. P.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2015, 35 (08) : 1296 - 1303
  • [2] Impact of Revascularization on Absolute Myocardial Blood Flow as Assessed by Serial [15O]H2O Positron Emission Tomography Imaging: A Comparison With Fractional Flow Reserve
    Driessen, Roel S.
    Danad, Ibrahim
    Stuijfzand, Wijnand J.
    Schumacher, Stefan P.
    Knuuti, Juhani
    Maki, Maija
    Lammertsma, Adriaan A.
    van Rossum, Albert C.
    van Royen, Niels
    Raijmakers, Pieter G.
    Knaapen, Paul
    CIRCULATION-CARDIOVASCULAR IMAGING, 2018, 11 (05) : e007417
  • [3] Comparison of simultaneous arterial spin labeling MRI and 15O-H2O PET measurements of regional cerebral blood flow in rest and altered perfusion states
    Puig, Oriol
    Henriksen, Otto M.
    Vestergaard, Mark B.
    Hansen, Adam E.
    Andersen, Flemming L.
    Ladefoged, Claes N.
    Rostrup, Egill
    Larsson, Henrik B. W.
    Lindberg, Ulrich
    Law, Ian
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2020, 40 (08) : 1621 - 1633
  • [4] Comparison of Methods for Quantification of rCBF on the HRRT PET Scanner Using [15O]H2O
    Walker, Matthew D.
    Feldmann, Maria
    Anton-Rodriguez, Jose M.
    Wang, Shaonan
    Matthews, Julian C.
    Koepp, Matthias J.
    Asselin, Marie-Claude
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2966 - 2971
  • [5] Defining the prognostic value of [15O]H2O positron emission tomography-derived myocardial ischaemic burden
    van Diemen, Pepijn A.
    Wijmenga, Jan-Thijs
    Driessen, Roel S.
    Bom, Michiel J.
    Schumacher, Stefan P.
    Stuijfzand, Wynand J.
    Everaars, Henk
    de Winter, Ruben W.
    Raijmakers, Pieter G.
    van de Ven, Peter M.
    van Rossum, Albert C.
    Danad, Ibrahim
    Knaapen, Paul
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2021, 22 (06) : 638 - 646
  • [6] Identifying Hypoperfusion in Moyamoya Disease With Arterial Spin Labeling and an [15O]-Water Positron Emission Tomography/Magnetic Resonance Imaging Normative Database
    Fan, Audrey P.
    Khalighi, Mohammad M.
    Guo, Jia
    Ishii, Yosuke
    Rosenberg, Jarrett
    Wardak, Mirwais
    Park, Jun Hyung
    Shen, Bin
    Holley, Dawn
    Gandhi, Harsh
    Haywood, Tom
    Singh, Prachi
    Steinberg, Gary K.
    Chin, Frederick T.
    Zaharchuk, Greg
    STROKE, 2019, 50 (02) : 373 - 380
  • [7] Semi-quantitative cerebral blood flow parameters derived from non-invasive [15O]H2O PET studies
    Koopman, Thomas
    Yaqub, Maqsood
    Heijtel, Dennis F. R.
    Nederveen, Aart J.
    van Berckel, Bart N. M.
    Lammertsma, Adriaan A.
    Boellaard, Ronald
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2019, 39 (01) : 163 - 172
  • [8] Comparison between cardiac magnetic resonance stress T1 mapping and [15O]H2O positron emission tomography in patients with suspected obstructive coronary artery disease
    Everaars, Henk
    van Diemen, Pepijn A.
    Biesbroek, P. Stefan
    Hopman, Luuk H. G. A.
    Bom, Michiel J.
    Schumacher, Stefan P.
    de Winter, Ruben W.
    van de Ven, Peter M.
    Raijmakers, Pieter G.
    Lammertsma, Adriaan A.
    Hofman, Mark B. M.
    Nijveldt, Robin
    Gotte, Marco J.
    van Rossum, Albert C.
    Danad, Ibrahim
    Driessen, Roel S.
    Knaapen, Paul
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2022, 23 (02) : 229 - 237
  • [9] Noninvasive parametric blood flow imaging of head and neck tumours using [15O]H2O and PET/CT
    Komar, Gaber
    Oikonen, Vesa
    Sipila, Hannu
    Seppanen, Marko
    Minn, Heikki
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (11) : 1169 - 1178
  • [10] Spatial coefficient of variation in pseudo-continuous arterial spin labeling cerebral blood flow images as a hemodynamic measure for cerebrovascular steno-occlusive disease: A comparative 15O positron emission tomography study
    Ibaraki, Masanobu
    Nakamura, Kazuhiro
    Toyoshima, Hideto
    Takahashi, Kazuhiro
    Matsubara, Keisuke
    Umetsu, Atsushi
    Pfeuffer, Josef
    Kuribayashi, Hideto
    Kinoshita, Toshibumi
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2019, 39 (01) : 173 - 181