Validation of the only commercially available immunoassay for synthetic cathinones in urine: Randox Drugs of Abuse V Biochip Array Technology

被引:42
作者
Ellefsen, Kayla N. [1 ,2 ]
Anizan, Sebastien [1 ]
Castaneto, Marisol S. [1 ,2 ]
Desrosiers, Nathalie A. [1 ,2 ]
Martin, Thomas M. [3 ]
Klette, Kevin L. [3 ]
Huestis, Marilyn A. [1 ]
机构
[1] NIDA, NIH, Baltimore, MD 21224 USA
[2] Univ Maryland, Toxicol Program, Baltimore, MD 21201 USA
[3] Off Secretary Def Operat Readiness & Safety, Washington, DC USA
基金
美国国家卫生研究院;
关键词
synthetic cathinones; mephedrone; MDPV; Randox; immunoassay; TANDEM MASS-SPECTROMETRY; DESIGNER DRUGS; BATH SALTS; FATAL INTOXICATIONS; RECREATIONAL DRUGS; UNITED-STATES; MEPHEDRONE; METHYLONE; TOXICITY; 3,4-METHYLENEDIOXYPYROVALERONE;
D O I
10.1002/dta.1633
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Deterrence of synthetic cathinone abuse is hampered by the lack of a high-throughput immunoassay screen. The Randox Drugs of Abuse V (DOA-V) Biochip Array Technology contains two synthetic cathinone antibodies: Bath Salt I (BSI) targets mephedrone/methcathinone and Bath Salt II (BSII) targets 3',4'-methylenedioxypyrovalerone (MDPV)/3',4'-methylenedioxy-alpha-pyrrolidinobutiophenone (MDPBP). We evaluated DOA-V synthetic cathinones performance and conducted a full validation on the original assay with calibrators reconstituted in water, and the new assay with calibrators prepared in lyophilized urine; both utilized the same antibodies and were run on the fully automated Evidence (R) Analyzer. We screened 20 017 authentic military urine specimens and confirmed positives by liquid chromatography-tandem mass spectrometry (LC-MS/MS) for 28 synthetic cathinones. Limits of detection (LOD) for the original and new assays were 0.35 and 0.18 (BSI), and 8.5 and 9.2 mu g/L (BSII), respectively. Linearity was acceptable (R-2 > 0.98); however, a large negative bias was observed with in-house prepared calibrators. Intra-assay imprecision was < 20% BSI-II, while inter-assay imprecision was 18-42% BSI and < 22% BSII. Precision was acceptable for Randox controls. Cross-reactivities of many additional synthetic cathinones were determined. Authentic drug-free negative urine pH < 4 produced false positive results for BSI (6.3 mu g/L) and BSII (473 mu g/L). Oxidizing agents reduced BSI and increased BSII results. Sensitivity, specificity, and efficiency of 100%, 52.1%, and 53.0% were obtained at manufacturer's proposed cut-offs (BSI 5 mu g/L, BSII 30 mu g/L). Performance improved if cut-off concentrations increased (BSI 7.5 mu g/L, BSII 40 mu g/L); however, there were limited confirmed positive specimens. Currently, this is the first and only fully validated immunoassay for preliminary detection of synthetic cathinones in urine. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.
引用
收藏
页码:728 / 738
页数:11
相关论文
共 61 条
[1]   Fatal Mephedrone IntoxicationuA Case Report [J].
Adamowicz, Piotr ;
Tokarczyk, Bogdan ;
Stanaszek, Roman ;
Slopianka, Markus .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2013, 37 (01) :37-42
[2]  
American Association of Poison Control Centers (AAPCC), 2013, AL BATH SALTS
[3]   Detection and Quantification of New Designer Drugs in Human Blood: Part 1 Synthetic Cannabinoids [J].
Ammann, Julia ;
McLaren, Jenna M. ;
Gerostamoulos, Dimitri ;
Beyer, Jochen .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2012, 36 (06) :372-380
[4]   Psychoactive "bath salts": Not so soothing [J].
Baumann, Michael H. ;
Partilla, John S. ;
Lehner, Kurt R. .
EUROPEAN JOURNAL OF PHARMACOLOGY, 2013, 698 (1-3) :1-5
[5]   Development of a rapid LC-MS/MS method for direct urinalysis of designer drugs [J].
Bell, Charlotte ;
George, Claire ;
Kicman, Andrew T. ;
Traynor, Allan .
DRUG TESTING AND ANALYSIS, 2011, 3 (7-8) :496-504
[6]   Hyperthermia and Multiorgan Failure After Abuse of "Bath Salts" Containing 3,4-Methylenedioxypyrovalerone [J].
Borek, Heather A. ;
Holstege, Christopher P. .
ANNALS OF EMERGENCY MEDICINE, 2012, 60 (01) :103-105
[7]   Sudden Cardiac Death Associated With Methylone Use [J].
Carbone, Peter N. ;
Carbone, David L. ;
Carstairs, Shaun D. ;
Luzi, Scott A. .
AMERICAN JOURNAL OF FORENSIC MEDICINE AND PATHOLOGY, 2013, 34 (01) :26-28
[8]   Distribution of Methylone in Four Postmortem Cases [J].
Cawrse, Brian M. ;
Levine, Barry ;
Jufer, Rebecca A. ;
Fowler, David R. ;
Vorce, Shawn P. ;
Dickson, Amber J. ;
Holler, Justin M. .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2012, 36 (06) :434-439
[9]   Simultaneous quantification of 28 synthetic cathinones and metabolites in urine by liquid chromatography-high resolution mass spectrometry [J].
Concheiro, Marta ;
Anizan, Sebastien ;
Ellefsen, Kayla ;
Huestis, Marilyn A. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (29) :9437-9448
[10]  
*DEA, 2011, NAT FOR LAB INF SYST