An experimental study of intra aortic balloon pumping within the intact human aorta

被引:9
作者
Tierney, G [1 ]
Parissis, H [1 ]
Baker, M [1 ]
Austin, D [1 ]
Clelland, C [1 ]
Richens, D [1 ]
机构
[1] CITY HOSP NOTTINGHAM,DEPT CARDIAC SURG,NOTTINGHAM NG5 1PB,ENGLAND
关键词
intra-aortic balloon counterpulsation; artificial circulation; thoracic aorta;
D O I
10.1016/S1010-7940(97)01205-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Intra-aortic balloon pumping is a therapeutic technique which carries a significant morbidity related to the intel action between the balloon catheter and the aorta. The aim of this study was to visualise directly the dynamic action of the balloon catheter within the cadaveric human aorta in an artificial circulation. Methods: An artificial circulation was constructed using of PVC tubing, a filter and a roller pump. A series of five intact cadaveric human aortas were then individually studied by placing each in series within the circuit. A balloon catheter was advanced via the left common iliac artery into the descending aorta under direct angioscopic vision. Balloon pumping was then commenced. The circuit was perfused with normal saline at a flow rate of 3 1/min. Pump actions of 1:1 and 1:2 were simulated. Each aorta at the end of the experiment was subjected to histological examination. Result: The balloon only appeared to make direct contact with the wall of the aorta during deflation when it was swept to one side by the circulating fluid. During maximal inflation the only points of contact were the tip of the catheter and the entry site. Side branches of the aorta were not occluded by the balloon. There was considerable atheromatous debris visualised within the lumen of the aorta. Atheromatous plaques were seen to fissure and disrupt by a pressure wave action and not by direct contact with the balloon. Conclusion: The balloon catheter moves relative to the wall of the aorta during inflation and dt nation. Contact between the balloon and the aorta only occurs during deflation. Side branches of the aorta are not occluded by the catheter. Plaque disruption and embolus formation appear to result from pressure wave action rather than direct contact with the balloon. This may have implications for future balloon design. Further investigation of this poorly understood interaction between the balloon and the aortic wall is required. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:486 / 493
页数:8
相关论文
共 17 条
[1]   COMPLICATIONS FROM INTRAAORTIC BALLOON COUNTERPULSATION - A REVIEW OF 303 CARDIAC SURGICAL PATIENTS [J].
ALVAREZ, JM ;
GATES, R ;
ROWE, D ;
BRADY, PW .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 (10) :530-535
[2]   VASCULAR COMPLICATIONS FROM INTRAAORTIC BALLOONS - RISK ANALYSIS [J].
BARNETT, MG ;
SWARTZ, MT ;
PETERSON, GJ ;
NAUNHEIM, KS ;
PENNINGTON, DG ;
VACA, KJ ;
FIORE, AC ;
MCBRIDE, LR ;
PEIGH, P ;
WILLMAN, VL ;
KAISER, GC .
JOURNAL OF VASCULAR SURGERY, 1994, 19 (01) :81-89
[3]   RESULTS AND COMPLICATIONS OF INTRA-AORTIC BALLOON COUNTERPULSATION [J].
BECKMAN, CB ;
GEHA, AS ;
HAMMOND, GL ;
BAUE, AE .
ANNALS OF THORACIC SURGERY, 1977, 24 (06) :550-559
[4]  
CORNHILL JF, 1990, MONOGR ATHEROSCLER B, V15, P1
[5]   PLAQUE ABRASION AND INTRAAORTIC BALLOON LEAK [J].
COX, PM ;
GORAN, SF ;
MORTON, J ;
WOLVEK, S .
CHEST, 1995, 108 (06) :1495-1498
[6]   EXPERIENCE IN 100 TRANSTHORACIC BALLOON PUMPS [J].
HAZELRIGG, SR ;
AUER, JE ;
SEIFERT, PE .
ANNALS OF THORACIC SURGERY, 1992, 54 (03) :528-532
[7]   COMPLICATIONS OF THE INTRA-AORTIC BALLOON COUNTERPULSATION DEVICE - CLINICAL AND MORPHOLOGIC OBSERVATIONS IN 45 NECROPSY PATIENTS [J].
ISNER, JM ;
COHEN, SR ;
VIRMANI, R ;
LAWRINSON, W ;
ROBERTS, WC .
AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02) :260-268
[8]   INTRAAORTIC BALLOON PUMPING 1967 THROUGH 1982 - ANALYSIS OF COMPLICATIONS IN 733 PATIENTS [J].
KANTROWITZ, A ;
WASFIE, T ;
FREED, PS ;
RUBENFIRE, M ;
WAJSZCZUK, W ;
SCHORK, MA .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (11) :976-983
[9]  
MAKHOUL RG, 1993, AM SURGEON, V59, P564
[10]  
MARTIN RS, 1983, J THORAC CARDIOV SUR, V85, P186