Repeatability of heart rate variability measures

被引:131
作者
Schroeder, EB
Whitsel, EA
Evans, GW
Prineas, RJ
Chambless, LE
Heiss, G
机构
[1] Univ N Carolina, Dept Epidemiol, Chapel Hill, NC 27514 USA
[2] Univ N Carolina, Dept Med, Chapel Hill, NC 27514 USA
[3] Univ N Carolina, Dept Biostat, Sch Publ Hlth, Chapel Hill, NC 27514 USA
[4] Duke Univ, Sch Med, Durham, NC USA
[5] Wake Forest Univ, Sch Med, Dept Publ Hlth Sci, Winston Salem, NC 27109 USA
关键词
autonomic nervous system; heart rate variability; reliability; repeatability;
D O I
10.1016/j.jelectrocard.2004.04.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Due to the sparse data on the repeatability of short and ultra-short term heart rate variability (HRV) measures, we measured the repeatability of common HRV measures derived from 10-second, 2-minute, and 6-minute recordings in 63 healthy men and women, aged 45-64, in Chapel Hill, North Carolina. Three 10-second and 2 six-minute heart rate recordings were obtained during each of 2 visits, separated by I to 2 weeks. We partitioned the measurement error into components and computed intraclass correlation coefficients using nested, random effects models. Repeatability improved with the length of recording: intraclass correlation coefficients were greater than 0.7 for 6-minute measures and 2-minute time domain measures and greater than 0.5 for 2-minute frequency domain measures. Repeatability of measures from 10-second records was lower, but improved considerably when the mean from 2 or 3 records was used. Correlations between the same measures from different length recordings were quite high. Our findings support the use of records of at least 5 minutes in length in epidemiological studies, in accordance with previous guidelines. Researchers using 10-second records should consider taking the mean of several recordings, when possible, or using statistical methods to correct for measurement error.
引用
收藏
页码:163 / 172
页数:10
相关论文
共 39 条
[1]   EFFECT OF PHYSIOLOGICAL AND PHARMACOLOGICAL ADRENERGIC-STIMULATION ON HEART-RATE-VARIABILITY [J].
AHMED, MW ;
KADISH, AH ;
PARKER, MA ;
GOLDBERGER, JJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) :1082-1090
[2]   Reliability of noninvasive methods to measure cardiac autonomic function [J].
Amara, CE ;
Wolfe, LA .
CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 1998, 23 (04) :396-408
[3]   FREQUENCY-DOMAIN MEASURES OF HEART PERIOD VARIABILITY AND MORTALITY AFTER MYOCARDIAL-INFARCTION [J].
BIGGER, JT ;
FLEISS, JL ;
STEINMAN, RC ;
ROLNITZKY, LM ;
KLEIGER, RE ;
ROTTMAN, JN .
CIRCULATION, 1992, 85 (01) :164-171
[4]  
Camm AJ, 1996, CIRCULATION, V93, P1043
[5]  
Carroll RJ., 1995, MEASUREMENT ERROR NO
[6]   Analysis of associations with change in a multivariate outcome variable when baseline is subject to measurement error [J].
Chambless, LE ;
Davis, V .
STATISTICS IN MEDICINE, 2003, 22 (07) :1041-1067
[7]   Repeatability of spectral components of short-term blood pressure and heart rate variability during acute sympathetic activation in healthy young male subjects [J].
CloarecBlanchard, L ;
FunckBrentano, C ;
Lipski, M ;
Jaillon, P ;
MacquinMavier, I .
CLINICAL SCIENCE, 1997, 93 (01) :21-28
[8]  
de Bruyne MC, 1999, AM J EPIDEMIOL, V150, P1282
[9]   Low heart rate variability in a 2-minute rhythm strip predicts risk of coronary heart disease and mortality from several causes - The ARIC study [J].
Dekker, JM ;
Crow, RS ;
Folsom, AR ;
Hannan, PJ ;
Liao, D ;
Swenne, CA ;
Schouten, EG .
CIRCULATION, 2000, 102 (11) :1239-1244
[10]  
Dekker JM, 1997, AM J EPIDEMIOL, V145, P899, DOI 10.1093/oxfordjournals.aje.a009049