A new HILIC-MS/MS method for the simultaneous analysis of carbidopa, levodopa, and its metabolites in human plasma

被引:32
作者
Vilhena, Raquel de Oliveira [1 ]
Degaut Pontes, Flavia Lada [1 ]
Marson, Breno Mauricio [1 ]
Ribeiro, Romulo Pereira [1 ]
Teixeira de Carvalho, Katherine Athayde [2 ]
Cardoso, Marco Andre [1 ,2 ]
Pontarolo, Roberto [1 ]
机构
[1] Univ Fed Parana, Dept Pharm, BR-80210170 Curitiba, Parana, Brazil
[2] Pele Pequeno Principe Inst Res, Curitiba, Parana, Brazil
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2014年 / 967卷
关键词
HILIC-MS/MS; Levodopa; Carbidopa; Parkinson's disease; Drug monitoring; PERFORMANCE LIQUID-CHROMATOGRAPHY; HYDROPHILIC-INTERACTION CHROMATOGRAPHY; L-DOPA; MASS-SPECTROMETRY; REVERSED-PHASE; 3-O-METHYLDOPA; HPLC; NEUROTRANSMITTERS; SAMPLES; ENTACAPONE;
D O I
10.1016/j.jchromb.2014.06.030
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Monitoring of the plasmatic levels of levodopa (LEV) and carbidopa (CAR) is necessary to adjust the dose of these drugs according to the individual needs of Parkinson's disease patients. To support drug therapeutic monitoring, a method using HILIC mode and LC-MS/MS was developed for the simultaneous determination of carbidopa, levodopa, and its metabolites (3-o-methyldopa (3-OMD) and dopamine (DOPA)) in human plasma. A triple quadrupole mass spectrometry was operated under the multiple reaction-monitoring mode (MRM) using the electrospray ionization technique. After straightforward sample preparation via protein precipitation, an Atlantis HILIC (150 x 2.1 mm, 3 pm, Waters, USA) column were used for separation under the isocratic condition of acetonitrile/water (79:21, v/v) containing 0.05% formic acid and 3 mmol/L ammonium formate and the total run time was 7 min. Deuterated LEV was used as internal standard for quantification. The developed method was validated in human plasma with a lower limit of quantitation of 75 ng/mL for LEV, 65 ng/mL for CAR and 3-OMD, and 20 ng/mL for DOPA. The calibration curve was linear within the concentration range of 75-800 ng/mL for LEV, 65-800 ng/mL for CAR and 3-0MD, and 20-400 ng/mL for DOPA (r>0.99). The assay was accurate and precise, with inter-assay and intra-assay accuracies within +/- 13.44% of nominal and inter-assay and intra-assay precision <= 13.99%. All results were within the acceptance criteria of the US FDA and AN VISA guidelines for method validation. LEV, CAR, 3-OMD and DOPA were stable in the battery of stability studies, long-term, bench-top, autosampler, and freeze/thaw cycles. Samples from patients undergoing treatment were analyzed, and the results indicated that this new method is suitable for therapeutic drug monitoring in Parkinson's disease patients. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:41 / 49
页数:9
相关论文
共 43 条
[1]   HYDROPHILIC-INTERACTION CHROMATOGRAPHY FOR THE SEPARATION OF PEPTIDES, NUCLEIC-ACIDS AND OTHER POLAR COMPOUNDS [J].
ALPERT, AJ .
JOURNAL OF CHROMATOGRAPHY, 1990, 499 :177-196
[2]   Bimodal administration of entacapone in Parkinson's disease patients improves motor control [J].
Bet, L. ;
Bareggi, S. R. ;
Pacei, F. ;
Bondiolotti, G. ;
Meola, G. ;
Schapira, A. H. V. .
EUROPEAN JOURNAL OF NEUROLOGY, 2008, 15 (03) :268-273
[3]   Determination of L-dopa, carbidopa, 3-O-methyldopa and entacapone in human plasma by HPLC-ED [J].
Bugamelli, F. ;
Marcheselli, C. ;
Barba, E. ;
Raggi, M. A. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (03) :562-567
[4]   Hydrophilic interaction liquid chromatography (HILIC)-a powerful separation technique [J].
Buszewski, Boguslaw ;
Noga, Sylwia .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (01) :231-247
[5]   Determination of dansylated monoamine and amino acid neurotransmitters and their metabolites in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry [J].
Cai, Hua-Lin ;
Zhu, Rong-Hua ;
Li, Huan-De .
ANALYTICAL BIOCHEMISTRY, 2010, 396 (01) :103-111
[6]   Simultaneous measurement of adenosine, dopamine, acetylcholine and 5-hydroxytryptamine in cerebral mice microdialysis samples by LC-ESI-MS/MS [J].
Cannazza, Giuseppe ;
Carrozzo, Marina M. ;
Cazzato, Addolorata S. ;
Bretis, Irina M. ;
Troisi, Luigino ;
Parenti, Carlo ;
Braghiroli, Daniela ;
Guiducci, Stefania ;
Zoli, Michele .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 71 :183-186
[7]   SIMULTANEOUS DETERMINATION OF LEVODOPA, ITS METABOLITES AND CARBIDOPA IN CLINICAL-SAMPLES [J].
CEDARBAUM, JM ;
WILLIAMSON, R ;
KUTT, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 415 (02) :393-399
[8]   Simultaneous quantitation of levodopa and 3-O-methyldopa in human plasma by HPLC-ESI-MS/MS: Application for a pharmacokinetic study with a levodopa/benserazide formulation [J].
Cesar, Isabela da Costa ;
Duarte Byrro, Ricardo Martins ;
de Santana e Silva Cardoso, Fabiana Fernandes ;
Mundim, Iram Moreira ;
Teixeira, Leonardo de Souza ;
da Silva, Enikson Pontes ;
Gomes, Sandro Antonio ;
Bonfim, Ricardo Rodrigues ;
Pianetti, Gerson Antonio .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (05) :1094-1100
[9]   Approach to hydrophilic interaction chromatography column selection: Application to neurotransmitters analysis [J].
Chirita, Raluca-Ioana ;
West, Caroline ;
Finaru, Adriana-Luminita ;
Elfakir, Claire .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (18) :3091-3104
[10]   LC Evaluation of Intestinal Transport of Praziquantel [J].
Cinto, Priscila O. ;
Ribeiro Souza, Ana Luiza ;
Lima, Andrea C. ;
Chaud, Marco V. ;
Gremiao, Maria Palmira D. .
CHROMATOGRAPHIA, 2009, 69 :213-217