Design and optimization of a proton exchange membrane fuel cell CHP system for residential use

被引:66
作者
Gandiglio, M. [1 ]
Lanzini, A. [1 ]
Santarelli, M. [1 ]
Leone, P. [1 ]
机构
[1] Politecn Torino, I-10129 Turin, Italy
关键词
Micro-CHP; PEM fuel cell; Pinch analysis; Floor heating system; COMBINED HEAT; OPERATION;
D O I
10.1016/j.enbuild.2013.11.022
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This work deals with the analysis of a micro-cogeneration system for residential use based on a 1 kWe proton exchange membrane (PEM) fuel cell. A detailed system analysis of the fuel cell stack operating at an average temperature of 62 C and the surrounding balance-of-plant (BoP) are taken into account. The gas processing section and the heat recovery system were also designed and optimized in term of heat recovery. Low-grade waste heat, mainly recovered from the PEM stack and the burner exhaust, has been found suitable for feeding a low-temperature thermal user such a radiant floor heating system (operating at similar to 35-45 C). According to this configuration, the heat-exchanger network has been optimized following the pinch analysis methodology, and the floor heating system has been sized accordingly. The micro-cogeneration system has been modelled in term of mass and energy balances while efficiency maps were obtained for a varying fuel utilization and current density of the stack. The maximum electrical efficiency achieved is around 36% (AC, LHV), with a stack current of 30A and a Fuel Utilization (FU) of 80%. The global efficiency (that includes also heat recovery toward the thermal utility) is above 75% for same stack operating conditions. From the floor heating system sizing, the considered micro-CHP PEM system is able to supply around 22.4% of the heat demand by a 50 m(2) medium-low efficiency building (class E - EU classification) during the winter season. Nevertheless, taking into account a high efficiency building (class A++ - EU classification), the heat released by the PEM plant can supply the overall required thermal load without requiring an auxiliary boiler. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:381 / 393
页数:13
相关论文
共 34 条
[1]  
[Anonymous], UNI EN 1264 WATER BA
[2]  
[Anonymous], 2005, SUPPLEMENTO ORDINARI
[3]  
[Anonymous], 2003, OFFICIAL JOURNAL OF
[4]  
[Anonymous], UNITS 11300 2 ENERGY
[5]   Modeling and off-design performance of a 1 kWe HT-PEMFC (high temperature-proton exchange membrane fuel cell)-based residential micro-CHP (combined-heat-and-power) system for Danish single-family households [J].
Arsalis, Alexandros ;
Nielsen, Mads P. ;
Kaer, Soren K. .
ENERGY, 2011, 36 (02) :993-1002
[6]   Dynamic analysis of PEMFC-based CHP systems for domestic application [J].
Barelli, L. ;
Bidini, G. ;
Gallorini, F. ;
Ottaviano, A. .
APPLIED ENERGY, 2012, 91 (01) :13-28
[7]   An energetic-exergetic analysis of a residential CHP system based on PEM fuel cell [J].
Barelli, L. ;
Bidini, G. ;
Gallorini, F. ;
Ottaviano, A. .
APPLIED ENERGY, 2011, 88 (12) :4334-4342
[8]   An energetic-exergetic comparison between PEMFC and SOFC-based micro-CHP systems [J].
Barelli, L. ;
Bidini, G. ;
Gallorini, F. ;
Ottaviano, A. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (04) :3206-3214
[9]  
Climaplast&REG
[10]  
, PROJECT AND INSTALLA