Reproducibility of time-domain and three different frequency-domain techniques for the analysis of the signal-averaged electrocardiogram

被引:7
作者
Vázquez, R
Caref, EB
Torres, F
Reina, M
Guerrero, JA
El-Sherif, N
机构
[1] Vet Adm Med Ctr, Cardiol Sect 111A, Div Cardiol, Brooklyn, NY 11209 USA
[2] Valme Univ Hosp, Cardiol Unit, Seville, Spain
[3] SUNY Hlth Sci Ctr, Div Cardiol, Brooklyn, NY 11203 USA
关键词
time-domain analysis; frequency-domain analysis; signal-averaged electrocardiogram; reproducibility; ventricular arrhythmias; myocardial infarction;
D O I
10.1016/S0022-0736(00)80079-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Because rime-domain (TD) analysis of the signal-averaged ECG (SAECG) has some limitations that limit its use, several frequency-domain analysis techniques were developed in an attempt to improve the diagnostic ability of the SAECG. However, it is not known how reliable these techniques are at detecting late potentials. This prospective study compares the short-term reproducibility of 4 analysis techniques: TD analysis, spectral temporal map ping (STM), spectral turbulence analysis (STA), and acceleration spectrum analysis (ASA), in a large series of normal patients and post-myocardial infarction (MI) patients. Two consecutive SAECGs were recorded in 634 patients that were divided into 3 groups: 117 remote MI patients undergoing programmed electrical stimulation for the inducibility of ventricular tachycardia (Group 1). 407 consecutive acute MI survivors (Group 2), and in 110 healthy volunteers (Group 3). The diagnostic reproducibility of the 4 techniques was evaluated by comparing rates of inconsistent results (1 normal and the other abnormal). The numeric reproducibility for each technique was assessed by comparing the normalized differences of each single SAECG parameter between the 2 recordings. Inconsistent results of diagnostic reproducibility were observed in 4.1%, 6.9%, 9.8%, and 18.0%, with TD, STA, ASA, and STM, respectively. Comparisons of these rates were significantly different (P <.05) except between STA and ASA (P =.07). The numeric reproducibility was highest for TD parameters, lowest for STM factors of normality, and intermediate for STA and ASA indices. TD analysis remains the most reproducible SAECG analysis technique, whereas STM showed the worst reproducibility, which limits its clinical applicability. STA and ASA provide an acceptable intermediate reproducibility, the former being slightly, although nor significantly, more reproducible than the latter.
引用
收藏
页码:99 / 105
页数:7
相关论文
共 31 条
[1]   RECORDING FROM BODY-SURFACE OF ARRHYTHMOGENIC VENTRICULAR ACTIVITY DURING S-T SEGMENT [J].
BERBARI, EJ ;
SCHERLAG, BJ ;
HOPE, RR ;
LAZZARA, R .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (04) :697-702
[2]   SHORT-TERM AND LONG-TERM REPRODUCIBILITY OF THE SIGNAL-AVERAGED ELECTROCARDIOGRAM IN CORONARY-ARTERY DISEASE [J].
BORBOLA, J ;
DENES, P .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (13) :1123-1124
[3]  
Breithardt G, 1981, Eur Heart J, V2, P1
[4]   STANDARDS FOR ANALYSIS OF VENTRICULAR LATE POTENTIALS USING HIGH-RESOLUTION OR SIGNAL-AVERAGED ELECTROCARDIOGRAPHY - A STATEMENT BY A TASK-FORCE-COMMITTEE OF THE EUROPEAN-SOCIETY-OF-CARDIOLOGY, THE AMERICAN-HEART-ASSOCIATION, AND THE AMERICAN-COLLEGE-OF-CARDIOLOGY [J].
BREITHARDT, G ;
CAIN, ME ;
ELSHERIF, N ;
FLOWERS, NC ;
HOMBACH, V ;
JANSE, M ;
SIMSON, MB ;
STEINBECK, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (05) :999-1006
[5]   EFFECT OF CONDUCTION DEFECTS ON THE SIGNAL-AVERAGED ELECTROCARDIOGRAPHIC DETERMINATION OF LATE POTENTIALS [J].
BUCKINGHAM, TA ;
THESSEN, CC ;
STEVENS, LL ;
REDD, RM ;
KENNEDY, HL .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (15) :1265-1271
[6]   FAST-FOURIER TRANSFORM ANALYSIS OF SIGNAL-AVERAGED ELECTROCARDIOGRAMS FOR IDENTIFICATION OF PATIENTS PRONE TO SUSTAINED VENTRICULAR-TACHYCARDIA [J].
CAIN, ME ;
AMBOS, HD ;
WITKOWSKI, FX ;
SOBEL, BE .
CIRCULATION, 1984, 69 (04) :711-720
[7]   DIAGNOSTIC IMPLICATIONS OF SPECTRAL AND TEMPORAL ANALYSIS OF THE ENTIRE CARDIAC CYCLE IN PATIENTS WITH VENTRICULAR-TACHYCARDIA [J].
CAIN, ME ;
AMBOS, HD ;
MARKHAM, J ;
LINDSAY, BD ;
ARTHUR, RM .
CIRCULATION, 1991, 83 (05) :1637-1648
[8]   ROLE OF BANDPASS-FILTERS IN OPTIMIZING THE VALUE OF THE SIGNAL-AVERAGED ELECTROCARDIOGRAM AS A PREDICTOR OF THE RESULTS OF PROGRAMMED STIMULATION [J].
CAREF, EB ;
TURITTO, G ;
IBRAHIM, BB ;
HENKIN, R ;
ELSHERIF, N .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (01) :16-26
[9]  
CHAN EKY, 1996, ANN NONINVAS ELECTRO, V1, P306
[10]  
CRIPPS T, 1988, BRIT HEART J, V60, P181