T1-weighted MRI as a substitute to CT for refocusing planning in MR-guided focused ultrasound

被引:23
作者
Wintermark, Max [1 ,2 ]
Tustison, Nicholas J. [3 ]
Elias, William J. [4 ]
Patrie, James T. [5 ]
Xin, Wenjun [5 ]
Demartini, Nicholas [3 ]
Eames, Matt [6 ]
Sumer, Suna [1 ]
Lau, Benison [1 ]
Cupino, Alan [1 ]
Snell, John [6 ]
Hananel, Arik [6 ]
Kassell, Neal [4 ,6 ]
Aubry, Jean-Francois [7 ,8 ]
机构
[1] Univ Virginia, Dept Radiol, Neuroradiol Div, Charlottesville, VA USA
[2] CHU Vaudois, Dept Radiol, CH-1011 Lausanne, Switzerland
[3] Univ Virginia, Dept Radiol, Charlottesville, VA USA
[4] Univ Virginia, Dept Neurosurg, Charlottesville, VA USA
[5] Univ Virginia, Dept Publ Hlth Sci, Charlottesville, VA USA
[6] Focused Ultrasound Fdn, Charlottesville, VA USA
[7] Univ Virginia, Dept Radiat Oncol, Charlottesville, VA USA
[8] ESPCI ParisTech, Inst Langevin, CNRS, UMR 7587,INSERM,U979, Paris, France
关键词
MR-guided focused ultrasound; brain; CT; MRI; ESSENTIAL TREMOR; HUMAN SKULL; EX-VIVO; IN-VIVO; BRAIN; SURGERY; THERAPY; FEASIBILITY; THALAMOTOMY; BONE;
D O I
10.1088/0031-9155/59/13/3599
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Precise focusing is essential for transcranial MRI-guided focused ultrasound (TcMRgFUS) to minimize collateral damage to non-diseased tissues and to achieve temperatures capable of inducing coagulative necrosis at acceptable power deposition levels. CT is usually used for this refocusing but requires a separate study (CT) ahead of the TcMRgFUS procedure. The goal of this study was to determine whether MRI using an appropriate sequence would be a viable alternative to CT for planning ultrasound refocusing in TcMRgFUS. We tested three MRI pulse sequences (3D T1 weighted 3D volume interpolated breath hold examination (VIBE), proton density weighted 3D sampling perfection with applications optimized contrasts using different flip angle evolution and 3D true fast imaging with steady state precision T2-weighted imaging) on patients who have already had a CT scan performed. We made detailed measurements of the calvarial structure based on the MRI data and compared those so-called 'virtual CT' to detailed measurements of the calvarial structure based on the CT data, used as a reference standard. We then loaded both standard and virtual CT in a TcMRgFUS device and compared the calculated phase correction values, as well as the temperature elevation in a phantom. A series of Bland-Altman measurement agreement analyses showed T1 3D VIBE as the optimal MRI sequence, with respect to minimizing the measurement discrepancy between the MRI derived total skull thickness measurement and the CT derived total skull thickness measurement (mean measurement discrepancy: 0.025; 95% CL (-0.22-0.27); p = 0.825). The T1-weighted sequence was also optimal in estimating skull CT density and skull layer thickness. The mean difference between the phase shifts calculated with the standard CT and the virtual CT reconstructed from the T1 dataset was 0.08 +/- 1.2 rad on patients and 0.1 +/- 0.9 rad on phantom. Compared to the real CT, the MR-based correction showed a 1 degrees C drop on the maximum temperature elevation in the phantom (7% relative drop). Without any correction, the maximum temperature was down 6 degrees C (43% relative drop). We have developed an approach that allows for a reconstruction of a virtual CT dataset from MRI to perform phase correction in TcMRgFUS.
引用
收藏
页码:3599 / 3614
页数:16
相关论文
共 36 条
[1]  
[Anonymous], GLOB PUBLIC HEALTH
[2]   Experimental demonstration of noninvasive transskull adaptive focusing based on prior computed tomography scans [J].
Aubry, JF ;
Tanter, M ;
Pernot, M ;
Thomas, JL ;
Fink, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 113 (01) :84-93
[3]   An Open Source Multivariate Framework for n-Tissue Segmentation with Evaluation on Public Data [J].
Avants, Brian B. ;
Tustison, Nicholas J. ;
Wu, Jue ;
Cook, Philip A. ;
Gee, James C. .
NEUROINFORMATICS, 2011, 9 (04) :381-400
[4]   A reproducible evaluation of ANTs similarity metric performance in brain image registration [J].
Avants, Brian B. ;
Tustison, Nicholas J. ;
Song, Gang ;
Cook, Philip A. ;
Klein, Arno ;
Gee, James C. .
NEUROIMAGE, 2011, 54 (03) :2033-2044
[5]   The optimal template effect in hippocampus studies of diseased populations [J].
Avants, Brian B. ;
Yushkevich, Paul ;
Pluta, John ;
Minkoff, David ;
Korczykowski, Marc ;
Detre, John ;
Gee, James C. .
NEUROIMAGE, 2010, 49 (03) :2457-2466
[6]  
Chauvet D, 2013, J NEUROSURG, P1
[7]   A non-invasive method for focusing ultrasound through the human skull [J].
Clement, GT ;
Hynynen, K .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (08) :1219-1236
[8]   Micro-receiver guided transcranial beam steering [J].
Clement, GT ;
Hynynen, K .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (04) :447-453
[9]  
Conrady A E, 1992, APPL OPTICS OPTICA 1
[10]  
Foley J., 2013, Imaging Medicine, V5, P357, DOI DOI 10.2217/IIM.13.38