Electrochemical Detection of Selenium (IV) and (VI) at Gold-Modified Diamond Electrodes

被引:18
作者
Ivandini, Tribidasari A. [1 ,2 ]
Einaga, Yasuaki [1 ,3 ]
机构
[1] Keio Univ, Fac Sci & Technol, Dept Chem, Yokohama, Kanagawa 2230035, Japan
[2] Univ Indonesia, Fac Math & Sci, Dept Chem, Jakarta 16424, Indonesia
[3] JST CREST, Yokohama, Kanagawa 2230035, Japan
关键词
Selenium (IV) and (VI); Speciation; Cyclic voltammetry; Gold-modified boron-doped diamond; electrodes; ANODIC-STRIPPING VOLTAMMETRY; ATOMIC-ABSORPTION-SPECTROMETRY; SELECTIVE DETECTION; SE(IV); WATER; SE; REDUCTION; BEHAVIOR; SPECIATION; SE(VI);
D O I
10.1007/s12678-013-0169-7
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Electrochemical detection of Se (IV) and (VI) was investigated at gold-modified boron-doped diamond electrodes. Cyclic voltammetry in acid condition showed that the onset of current flows of Se (IV) and Se (VI) occurred at almost similar potentials. Furthermore, the currents at the peak potential of similar to 0.9 V (vs. Ag/AgCl) showed high linearity against concentrations of both Se (IV) and Se (VI) with estimated limits of detection (S/N=3) of 20 and 50 ppb, respectively. However, whereas oxidation peaks of Se (IV) and Se (VI) can be observed in acid and neutral pH, only oxidation peak of Se (IV) appeared in high pH. The possibility to differentiate a mixture of Se (IV) and Se (VI) by applying cyclic voltammogram (CV) at acidic and basic conditions was discussed, and it was promising, especially because, previously, it always stated that Se (VI) was not electrochemically active.
引用
收藏
页码:367 / 374
页数:8
相关论文
共 32 条
[21]   Thick-film graphite-containing electrodes for determining selenium by stripping voltammetry [J].
Stozhko, NY ;
Shalygina, ZV ;
Malakhova, NA .
JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 59 (04) :374-380
[22]   Flow injection-hydride generation atomic absorption spectrometric determination of Se(VI) and Se(IV): utility of a conventionally heated water bath for the on-line reduction of Se(VI) [J].
Stripeikis, J ;
Costa, P ;
Tudino, M ;
Troccoli, O .
ANALYTICA CHIMICA ACTA, 2000, 408 (1-2) :191-197
[23]  
Tan SH, 1998, ELECTROANAL, V10, P364, DOI 10.1002/(SICI)1521-4109(199805)10:6<364::AID-ELAN364>3.0.CO
[24]  
2-F
[25]  
Tinggi U, 2005, R FOOD NUTRIT TOX, V4, P29
[26]   Selective detection and identification of Se containing compounds - review and recent developments [J].
Uden, PC ;
Boakye, HT ;
Kahakachchi, C ;
Tyson, JF .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1050 (01) :85-93
[27]  
US Environmental Protection Agency, 2013, TECHN FACTSH SEL
[28]   Selective detection method derived from a controlled diffusion process at metal-modified diamond electrodes [J].
Watanabe, Takeshi ;
Ivandini, Tribidasari A. ;
Makide, Yoshihiro ;
Fujishima, Akira ;
Einaga, Yasuaki .
ANALYTICAL CHEMISTRY, 2006, 78 (22) :7857-7860
[29]   A COMBINED VOLTAMMETRY AND ELECTROCHEMICAL QUARTZ-CRYSTAL MICROGRAVIMETRY STUDY OF THE REDUCTION OF AQUEOUS SE(IV) AT GOLD [J].
WEI, C ;
MYUNG, N ;
RAJESHWAR, K .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 375 (1-2) :109-115
[30]   Anodic stripping voltammetry of inorganic species of As3+ and As5+ at gold-modified boron doped diamond electrodes [J].
Yamada, Daisuke ;
Ivandini, Tribidasari A. ;
Komatsu, Motoharu ;
Fujishima, Akira ;
Einaga, Yasuaki .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 615 (02) :145-153