How does magnetization transfer influence mcDESPOT results?

被引:37
作者
Zhang, Jing [1 ]
Kolind, Shannon H. [2 ]
Laule, Cornelia [1 ,3 ]
MacKay, Alex L. [1 ,4 ]
机构
[1] Univ British Columbia, UBC MRI Res Ctr, Dept Radiol, Vancouver, BC V5Z 1M9, Canada
[2] Univ British Columbia, Dept Med, Div Neurol, Vancouver, BC V5Z 1M9, Canada
[3] Univ British Columbia, Dept Pathol & Lab Med, Vancouver, BC V5Z 1M9, Canada
[4] Univ British Columbia, Dept Phys & Astron, Vancouver, BC V5Z 1M9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
steady-state imaging; T-2; relaxation; myelin water fraction; magnetization transfer; STATE FREE PRECESSION; MYELIN WATER; STEADY-STATE; MULTIPLE-SCLEROSIS; T-2; RESONANCE; BRAIN; MRI; HISTOPATHOLOGY; QUANTIFICATION;
D O I
10.1002/mrm.25520
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeA steady-state approach that was termed multicomponent driven equilibrium single pulse observation of T-1 and T-2 (mcDESPOT) has recently been proposed for myelin water fraction (f(M)) mapping in brain development and demyelinating diseases. However, f(M)s estimated by mcDESPOT are significantly higher than myelin water fraction derived from multiecho spin echo T-2-decay curve approaches. Magnetization transfer (MT), enhanced by the use of short, relatively high amplitude radiofrequency (RF) pulses in mcDESPOT, may artifactually influence f(M) maps. Our goal was to investigate the role of MT in mcDESPOT. MethodsmcDESPOT data was collected twice from three healthy volunteers using short RF pulses with higher MT effect and long RF pulses with lower MT effect. MR parameters from 11 white and gray regions were compared using a paired student t-test. Whole slice difference images were also compared. ResultsMT effects had a substantial influence on the signal generated by the balanced steady-state free procession sequences used in mcDESPOT. However, these MT effects were not clearly evident in the f(M) values determined by the conventional two-pool mcDESPOT analysis. ConclusionThe signal generated from mcDESPOT is sensitive to MT, but the extracted myelin water fractions are relatively insensitive to changes of MT. Magn Reson Med 74:1327-1335, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1327 / +
页数:9
相关论文
共 35 条
[1]   MICROPHONE ARRAY OPTIMIZATION BY STOCHASTIC REGION CONTRACTION [J].
BERGER, MF ;
SILVERMAN, HF .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1991, 39 (11) :2377-2386
[2]  
Bernstein M.A., 2004, Handbook of MRI Pulse Sequences, P67
[3]   Optimized balanced steady-state free precession magnetization transfer Imaging [J].
Bieri, O. ;
Scheffler, K. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (03) :511-518
[4]   On the origin of apparent low tissue signals in balanced SSFD [J].
Bieri, O. ;
Scheffler, K. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (05) :1067-1074
[5]   SSFP Signal With Finite RF Pulses [J].
Bieri, Oliver ;
Scheffler, Klaus .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (05) :1232-1241
[6]   T1 and T2 effects during radio-frequency pulses in spoiled gradient echo sequences [J].
Boulant, Nicolas .
JOURNAL OF MAGNETIC RESONANCE, 2009, 197 (02) :213-218
[7]   STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE [J].
CARR, HY .
PHYSICAL REVIEW, 1958, 112 (05) :1693-1701
[8]   Finite RF Pulse Correction on DESPOT2 [J].
Crooijmans, H. J. A. ;
Scheffler, K. ;
Bieri, O. .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (03) :858-862
[9]   Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state [J].
Deoni, SCL ;
Rutt, BK ;
Peters, TM .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (03) :515-526
[10]  
Deoni SCL, 2014, MAGN RESON MED