Value of repeated measures of nerve conduction and quantitative sensory testing in a diabetic neuropathy trial

被引:35
作者
Bird, Shawn J.
Brown, Mark J.
Spino, Cathie
Watling, Sharon
Foyt, Howard L.
机构
[1] Pfizer Global Res & Dev, Ann Arbor Labs, Ann Arbor, MI 48105 USA
[2] Univ Penn, Sch Med, Dept Neurol, Philadelphia, PA 19104 USA
关键词
aldose reductase inhibitors; diabetic neuropathy; nerve conduction studies; quantitative sensory testing; zenarestat;
D O I
10.1002/mus.20577
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Conduct of a large, multicenter trial of the aldose reductase inhibitor zenarestat provided data on the reproducibility of multiple electrophysiologic (nerve conduction studies, NCS) and quantitative sensory (QST) tests. Baseline and 12-month electrophysiologic data from approximately 1100 patients at multiple centers were available for analysis. Intersite variability contributed minimally to overall test variance. All NCS tests were highly reproducible. Cool thermal and vibration QST thresholds, as measured by CASE IV instrumentation, were also highly reproducible. Intersubject variance accounted for the majority of variance for all parameters measured. Repeating NCS and QST measures decreased sample sizes needed to show statistical significance. Consideration of these observations, particularly with regard to QST, should aid in the design of future clinical trials investigating neuropathy.
引用
收藏
页码:214 / 224
页数:11
相关论文
共 30 条
  • [1] THE EXTENT OF SMALL FIBER SENSORY NEUROPATHY IN DIABETICS WITH PLANTAR FOOT ULCERATION
    ALI, Z
    CARROLL, M
    ROBERTSON, KP
    FOWLER, CJ
    [J]. JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1989, 52 (01) : 94 - 98
  • [2] *AM DIAB ASS AM AC, 1991, NEUROLOGY, V42, P1823
  • [3] *AM DIAB ASS AM AC, 1988, DIABETES, V37, P100
  • [4] Technology literature review: Quantitative sensory testing
    Chong P.S.T.
    Cros D.P.
    [J]. MUSCLE & NERVE, 2004, 29 (05) : 734 - 747
  • [5] Bird S.J., 2002, NEUROMUSCULAR DISORD, P598
  • [6] DYNAMIC FOOT PRESSURE AND OTHER STUDIES AS DIAGNOSTIC AND MANAGEMENT AIDS IN DIABETIC NEUROPATHY
    BOULTON, AJM
    HARDISTY, CA
    BETTS, RP
    FRANKS, CI
    WORTH, RC
    WARD, JD
    DUCKWORTH, T
    [J]. DIABETES CARE, 1983, 6 (01) : 26 - 33
  • [7] Comparison of a neurothesiometer and vibratron in measuring vibration perception thresholds and relationship to nerve conduction studies
    Bril, V
    Kojic, J
    Ngo, M
    Clark, K
    [J]. DIABETES CARE, 1997, 20 (09) : 1360 - 1362
  • [8] Bril V, 1998, MUSCLE NERVE, V21, P1368, DOI 10.1002/(SICI)1097-4598(199811)21:11<1368::AID-MUS2>3.3.CO
  • [9] 2-G
  • [10] Natural progression of diabetic peripheral neuropathy in the Zenarestat study population
    Brown, MJ
    Bird, SJ
    Watling, S
    Kaleta, H
    Hayes, L
    Eckert, S
    Foyt, HL
    [J]. DIABETES CARE, 2004, 27 (05) : 1153 - 1159