Development of an X-ray pixel detector with multi-port charge-coupled device for X-ray free-electron laser experiments

被引:215
作者
Kameshima, Takashi [1 ]
Ono, Shun [2 ]
Kudo, Togo [2 ]
Ozaki, Kyosuke [2 ]
Kirihara, Yoichi [2 ]
Kobayashi, Kazuo [2 ]
Inubushi, Yuichi [2 ]
Yabashi, Makina [1 ,2 ]
Horigome, Toshio [3 ]
Holland, Andrew [4 ]
Holland, Karen [4 ]
Burt, David [5 ]
Murao, Hajime [6 ]
Hatsui, Takaki [1 ,2 ]
机构
[1] JASRI, Sayo, Hyogo 6795198, Japan
[2] RIKEN SPring 8 Ctr, Sayo, Hyogo 6795198, Japan
[3] Inst Mol Sci, Okazaki, Aichi 4448585, Japan
[4] XCam Ltd, Northampton NN3 8RF, England
[5] e2v, Chelmsford CM1 2QU, Essex, England
[6] Meisei Elect Co Ltd, Gunma 3728585, Japan
关键词
PHOTON IMAGING CAMERA; XMM-NEWTON; SENSOR; SPECTROMETER; PERFORMANCE; SATELLITE; ASTRONOMY; SILICON; PULSES; ASCA;
D O I
10.1063/1.4867668
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper presents development of an X-ray pixel detector with a multi-port charge-coupled device (MPCCD) for X-ray Free-Electron laser experiments. The fabrication process of the CCD was selected based on the X-ray radiation hardness against the estimated annual dose of 1.6 x 10(14) photon/mm(2). The sensor device was optimized by maximizing the full well capacity as high as 5 Me- within 50 mu m square pixels while keeping the single photon detection capability for X-ray photons higher than 6 keV and a readout speed of 60 frames/s. The system development also included a detector system for the MPCCD sensor. This paper summarizes the performance, calibration methods, and operation status. (C) 2014 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:15
相关论文
共 46 条
[1]   Edgeless sensor development for the LPD hybrid pixel detector at XFEL [J].
Blue, Andrew ;
French, M. ;
Seller, P. ;
O'Shea, V. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01) :55-56
[2]   CCD SOFT-X-RAY IMAGING SPECTROMETER FOR THE ASCA SATELLITE [J].
BURKE, BE ;
MOUNTAIN, RW ;
DANIELS, PJ ;
COOPER, MJ ;
DOLAT, VS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (01) :375-385
[3]   Soft-x-ray CCD imagers for AXAF [J].
Burke, BE ;
Gregory, JA ;
Bautz, MW ;
Prigozhin, GY ;
Kissel, SE ;
Kosicki, BB ;
Loomis, AH ;
Young, DJ .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1997, 44 (10) :1633-1642
[4]  
Burt DJ, 1995, GEC-J RES, V12, P130
[5]   Charge-pump detector for X-ray correlation spectroscopy [J].
Carini, Gabriella A. ;
Rehak, Pavel ;
Chen, Wei ;
Siddons, D. Peter .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 649 (01) :75-77
[6]   A fast, direct x-ray detection charge-coupled device [J].
Denes, P. ;
Doering, D. ;
Padmore, H. A. ;
Walder, J. -P. ;
Weizeorick, J. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (08)
[7]  
Emma P, 2010, NAT PHOTONICS, V4, P641, DOI [10.1038/nphoton.2010.176, 10.1038/NPHOTON.2010.176]
[8]   Sub-electron readout noise in a Skipper CCD fabricated on high resistivity silicon [J].
Fernandez Moroni, Guillermo ;
Estrada, Juan ;
Cancelo, Gustavo ;
Holland, Stephen E. ;
Paolini, Eduardo E. ;
Diehl, H. Thomas .
EXPERIMENTAL ASTRONOMY, 2012, 34 (01) :43-64
[9]   THE X-RAY-ENERGY RESPONSE OF SILICON .A. THEORY [J].
FRASER, GW ;
ABBEY, AF ;
HOLLAND, A ;
MCCARTHY, K ;
OWENS, A ;
WELLS, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 350 (1-2) :368-378
[10]   Back-illuminated, fully-depleted CCD image sensors for use in optical and near-IR astronomy [J].
Groom, DE ;
Holland, SE ;
Levi, ME ;
Palaio, NP ;
Perlmutter, S ;
Stover, RJ ;
Wei, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 442 (1-3) :216-222