Biomechanical analysis of the upper thoracic spine after decompressive procedures

被引:17
|
作者
Healy, Andrew T. [1 ]
Lubelski, Daniel [2 ]
Mageswaran, Prasath [3 ]
Bhowmick, Deb A. [4 ]
Bartsch, Adam J. [3 ]
Benzel, Edward C. [1 ]
Mroz, Thomas E. [1 ]
机构
[1] Cleveland Clin, Neurol Inst, Dept Neurosurg, Cleveland, OH 44118 USA
[2] Cleveland Clin, Lerner Coll Med, Cleveland, OH 44195 USA
[3] Cleveland Clin, Head Neck & Spine Res Lab, Lutheran Hosp, Cleveland, OH 44195 USA
[4] Univ N Carolina, Dept Neurosurg, Chapel Hill, NC 27599 USA
关键词
Thoracic; Spine; Decompression; Costotransversectomy; Biomechanics; Cadaver; RIB CAGE; MOTION; STABILITY; STIFFNESS; STERNUM; MODEL;
D O I
10.1016/j.spinee.2013.11.035
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Decompressive procedures such as laminectomy, facetectomy, and costotransversectomy are routinely performed for various pathologies in the thoracic spine. The thoracic spine is unique, in part, because of the sternocostovertebral articulations that provide additional strength to the region relative to the cervical and lumbar spines. During decompressive surgeries, stability is compromised at a presently unknown point. PURPOSE: To evaluate thoracic spinal stability after common surgical decompressive procedures in thoracic spines with intact sternocostovertebral articulations. STUDY DESIGN: Biomechanical cadaveric study. METHODS: Fresh-frozen human cadaveric spine specimens with intact rib cages, C7-L1 (n=9), were used. An industrial robot tested all spines in axial rotation (AR), lateral bending (LB), and flexion-extension (FE) by applying pure moments (+/- 5 Nm). The specimens were first tested in their intact state and then tested after each of the following sequential surgical decompressive procedures at T4-T5 consisting of laminectomy; unilateral facetectomy; unilateral costotransversectomy, and subsequently instrumented fusion from T3-T7. RESULTS: We found that in all three planes of motion, the sequential decompressive procedures caused no statistically significant change in motion between T3-T7 or T1-T12 when compared with intact. In comparing between intact and instrumented specimens, our study found that instrumentation reduced global range of motion (ROM) between T1-T12 by 16.3% (p=.001), 12% (p=.002), and 18.4% (p=.0004) for AR, FE, and LB, respectively. Age showed a negative correlation with motion in FE (r= 0.78, p=.01) and AR (r= 0.7, p=.04). CONCLUSIONS: Thoracic spine stability was not significantly affected by sequential decompressive procedures in thoracic segments at the level of the true ribs in all three planes of motion in intact thoracic specimens. Age appeared to negatively correlate with ROM of the specimen. Our study suggests that thoracic spinal stability is maintained immediately after unilateral decompression at the level of the true ribs. These preliminary observations, however, do not depict the long-term sequelae of such procedures and warrant further investigation. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1010 / 1016
页数:7
相关论文
共 50 条
  • [1] Biomechanics of the lower thoracic spine after decompression and fusion: a cadaveric analysis
    Lubelski, Daniel
    Healy, Andrew T.
    Mageswaran, Prasath
    Benzel, Edward C.
    Mroz, Thomas E.
    SPINE JOURNAL, 2014, 14 (09) : 2216 - 2223
  • [2] BIOMECHANICAL EFFECTS OF LAMINECTOMY ON THORACIC SPINE STABILITY
    YOGANANDAN, N
    MAIMAN, DJ
    PINTAR, FA
    BENNETT, GJ
    LARSON, SJ
    SONNTAG, VKH
    DUNSKER, SB
    NEUROSURGERY, 1993, 32 (04) : 604 - 610
  • [3] How Does the Rib Cage Affect the Biomechanical Properties of the Thoracic Spine? A Systematic Literature Review
    Liebsch, Christian
    Wilke, Hans-Joachim
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [4] Biomechanical properties of human thoracic spine disc segments
    Stemper, B. D.
    Board, D.
    Yoganandan, N.
    Wolfla, C. E.
    JOURNAL OF CRANIOVERTEBRAL JUNCTION AND SPINE, 2010, 1 (01) : 18 - 22
  • [5] Pedicle and transverse process screws of the upper thoracic spine - Biomechanical comparison of loads to failure
    Heller, JG
    Shuster, JK
    Hutton, WC
    SPINE, 1999, 24 (07) : 654 - 658
  • [6] Mechanical analysis of the human cadaveric thoracic spine with intact rib cage
    Mannen, Erin M.
    Anderson, John T.
    Arnold, Paul M.
    Friis, Elizabeth A.
    JOURNAL OF BIOMECHANICS, 2015, 48 (10) : 2060 - 2066
  • [7] Biomechanical Analysis of the Proximal Adjacent Segment after Multilevel Instrumentation of the Thoracic Spine: Do Hooks Ease the Transition?
    Metzger, Melodie F.
    Robinson, Samuel T.
    Svet, Mark T.
    Liu, John C.
    Acosta, Frank L.
    GLOBAL SPINE JOURNAL, 2016, 6 (04) : 335 - 343
  • [8] Biomechanical Analysis of Derotation of the Thoracic Spine Using Pedicle Screws
    Cheng, Ivan
    Hay, David
    Iezza, Alex
    Lindsey, Derek
    Lenke, Lawrence G.
    SPINE, 2010, 35 (10) : 1039 - 1043
  • [9] A biomechanical assessment of thoracic spine stapling
    Puttlitz, Christian M.
    Masaru, Fujita
    Barkley, Antonia
    Diab, Mohammed
    Acaroglu, Emre
    SPINE, 2007, 32 (07) : 766 - 771
  • [10] BIOMECHANICAL ANALYSIS OF AN INDUCED JOINT DYSFUNCTION (SUBLUXATION-MIMIC) IN THE THORACIC SPINE OF RABBITS
    DEBOER, KF
    HANSEN, JM
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 1993, 16 (02) : 74 - 81