A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers

被引:28
作者
Avonto, Cristina [1 ]
Chittiboyina, Amar G. [1 ]
Rua, Diego [2 ]
Khan, Ikhlas A. [1 ,3 ]
机构
[1] Univ Mississippi, Natl Ctr Nat Prod Res, Pharmaceut Sci Res Inst, Sch Pharm, University, MS 38677 USA
[2] US FDA, Ctr Food Safety & Appl Nutr, College Pk, MD 20740 USA
[3] Univ Mississippi, Div Pharmacognosy, Dept Biomol Sci, Sch Pharm, University, MS 38677 USA
关键词
Skin sensitization; Electrophiles; In chemico alternative methods; Fluorescence assay; High throughput screening; ALLERGIC CONTACT-DERMATITIS; SESQUITERPENE LACTONE MIX; TEST H-CLAT; PEPTIDE REACTIVITY; IN-VITRO; CELL-LINE; MICHAEL ACCEPTORS; GUINEA PIG; POTENCY; ASSAY;
D O I
10.1016/j.taap.2015.09.027
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization, integrated approaches combining different chemical, biological and in silico methods are recommended to replace conventional animal tests. Chemical methods are intended to characterize the potential of a sensitizer to induce earlier molecular initiating events. The presence of an electrophilic mechanistic domain is considered one of the essential chemical features to covalently bind to the biological target and induce further haptenation processes. Current in chemico assays rely on the quantification of unreacted model nucleophiles after incubation with the candidate sensitizer. In the current study, a new fluorescence-based method, 'HTS-DCYA assay', is proposed. The assay aims at the identification of reactive electrophiles based on their chemical reactivity toward a model fluorescent thiol. The reaction workflow enabled the development of a High Throughput Screening (HTS) method to directly quantify the reaction adducts. The reaction conditions have been optimized to minimize solubility issues, oxidative side reactions and increase the throughput of the assay while minimizing the reaction time, which are common issues with existing methods. Thirty-six chemicals previously classified with LLNA, DPRA or KeratinoSens (TM) were tested as a proof of concept. Preliminary results gave an estimated 82% accuracy, 78% sensitivity, 90% specificity, comparable to other in chemico methods such as Cys-DPRA. In addition to validated chemicals, six natural products were analyzed and a prediction of their sensitization potential is presented for the first rime. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:177 / 184
页数:8
相关论文
共 50 条
  • [41] Use of a Real-Time Fluorescence Monitoring System for High-Throughput Screening for Prolyl Isomerase Inhibitors
    Mori, Tadashi
    Itami, Seima
    Yanagi, Tomotaka
    Tatara, Yota
    Takamiya, Mari
    Uchida, Takafumi
    [J]. JOURNAL OF BIOMOLECULAR SCREENING, 2009, 14 (04) : 419 - 424
  • [42] Method with high-throughput screening potential for antioxidative substances using Escherichia coli biosensor katG′::lux
    Tienaho, Jenni
    Sarjala, Tytti
    Franzen, Robert
    Karp, Matti
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2015, 118 : 78 - 80
  • [43] Detection of a decrease in green fluorescent protein fluorescence for the monitoring of cell death: An assay amenable to high-throughput screening technologies
    Steff, AM
    Fortin, M
    Arguin, C
    Hugo, P
    [J]. CYTOMETRY, 2001, 45 (04): : 237 - 243
  • [44] High Throughput Screening Method for Identifying Potential Agonists and Antagonists of Arabidopsis thaliana Cytokinin Receptor CRE1/AHK4
    Klimes, Pavel
    Turek, Dusan
    Mazura, Pavel
    Gallova, Lucia
    Spichal, Lukas
    Brzobohaty, Bretislav
    [J]. FRONTIERS IN PLANT SCIENCE, 2017, 8
  • [45] Variable Dose Analysis: A Novel High-throughput RNAi Screening Method for Drosophila Cells
    Sierzputowska, Katarzyna
    Baxter, Chris R.
    Housden, Benjamin E.
    [J]. BIO-PROTOCOL, 2018, 8 (24):
  • [46] Substrate arrays for fluorescence-based enzyme fingerprinting and high-throughput screening
    Reymond, Jean-Louis
    [J]. FLUORESCENCE METHODS AND APPLICATIONS: SPECTROSCOPY, IMAGING, AND PROBES, 2008, 1130 : 12 - 20
  • [47] Development of a fast CE method for high throughput screening of ecto-5'-nucleotidase inhibitors
    Raza, Rabia
    Bai, Yu
    Liu, Huwei
    [J]. ELECTROPHORESIS, 2018, 39 (20) : 2612 - 2618
  • [48] A new and efficient colorimetric high-throughput screening method for triacylglycerol lipase directed evolution
    Wang, Dan
    Wang, Jue
    Wang, Bo
    Yu, Hongwei
    [J]. JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2012, 82 : 18 - 23
  • [49] A High-Throughput Screening Method for the Directed Evolution of Hydroxynitrile Lyase towards Cyanohydrin Synthesis
    Zheng, Yu-Cong
    Ding, Liang-Yi
    Jia, Qiao
    Lin, Zuming
    Hong, Ran
    Yu, Hui-Lei
    Xu, Jian-He
    [J]. CHEMBIOCHEM, 2021, 22 (06) : 996 - 1000
  • [50] Development of fluorescence-based high throughput screening assays: choice of appropriate instrumentation
    Burns, D
    Alder, L
    Fan, YH
    McKeegan, E
    Warrior, U
    Beutel, B
    [J]. SYSTEMS AND TECHNOLOGIES FOR CLINICAL DIAGNOSTICS AND DRUG DISCOVERY, PROCEEDINGS OF, 1998, 3259 : 188 - 196