Fan-beam monochromatic x-ray CT using fluorescent x-rays excited by synchrotron radiation

被引:1
作者
Toyofuku, F [1 ]
Tokumori, K [1 ]
Kanda, S [1 ]
Higashida, Y [1 ]
Ohki, M [1 ]
Cho, T [1 ]
Nishimura, K [1 ]
Hyodo, K [1 ]
Ando, M [1 ]
Uyama, C [1 ]
机构
[1] Kyushu Univ, Sch Hlth Sci, Dept Radiol Technol, Higashi Ku, Fukuoka 81282, Japan
来源
MEDICAL APPLICATIONS OF PENETRATING RADIATION | 1999年 / 3770卷
关键词
synchrotron radiation; fluorescent x-ray; monochromatic x-ray CT; fan-beam; CdTe array detector;
D O I
10.1117/12.368188
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. Although various types of monochromatic x-ray CT systems using synchrotron radiation have been developed using a parallel x-ray beam for imaging of small samples with a high spatial resolution, imaging of large objects such as the human body have not been developed yet. We have developed a fan-beam monochromatic x-ray CT using fluorescent x-rays generated by irradiating metal targets by synchrotron radiation. A CdTe linear array detector of 512mm sensitive width was used in the photon counting mode. We made phantom experiments using fluorescent x-rays ranging from 32 to 75 k eV. Monochromatic x-ray CT images of a cylindrical lucite phantom filled with several contrast media have been obtained. Measured CT numbers are compared with linear attenuation coefficients, and they showed a good linearity over a wide range of contrast media concentrations.
引用
收藏
页码:48 / 56
页数:9
相关论文
共 20 条
  • [2] Dilmanian F A, 1992, Am J Physiol Imaging, V7, P175
  • [3] DYSON NA, 1990, XRAYS AATOMIC NUCL P
  • [4] PRODUCTION OF MONOENERGETIC X-RAYS FROM 8 TO 87 KEV
    HOFFMAN, EJ
    PHELPS, ME
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1974, 19 (01) : 19 - 35
  • [5] X-RAY TOMOGRAPHIC MICROSCOPY (XTM) USING SYNCHROTRON RADIATION
    KINNEY, JH
    NICHOLS, MC
    [J]. ANNUAL REVIEW OF MATERIALS SCIENCE, 1992, 22 : 121 - 152
  • [6] KONISHI K, 1985, P 16 INT C MED B 2 S, V23, P1531
  • [7] Local x-ray tomography for in vivo bone structure examinations
    Laib, A
    Rüegsegger, P
    [J]. MEDICAL PHYSICS, 1999, 26 (03) : 447 - 452
  • [8] LEDERER CM, 1978, TABLE ISOTOPES, P570
  • [9] MCCARTHY KJ, 1986, NUCL INSTRUM METH A, V287, P613
  • [10] Three-dimensional monochromatic x-ray computed tomography using synchrotron radiation
    Saito, T
    Kudo, H
    Takeda, T
    Itai, Y
    Tokumori, K
    Toyofuku, F
    Hyodo, K
    Ando, M
    Nishimura, K
    Uyama, C
    [J]. OPTICAL ENGINEERING, 1998, 37 (08) : 2258 - 2268