Examining clinical decision support integrity: is clinician self-reported data entry accurate?

被引:25
作者
Gupta, Anurag [1 ,2 ,3 ,4 ]
Raja, Ali S. [1 ,2 ,3 ,4 ]
Khorasani, Ramin [1 ,2 ,4 ]
机构
[1] Brigham & Womens Hosp, Ctr Evidence Based Imaging, Boston, MA 02115 USA
[2] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[3] Brigham & Womens Hosp, Dept Emergency Med, Boston, MA 02115 USA
[4] Harvard Univ, Sch Med, Boston, MA USA
关键词
PULMONARY-EMBOLISM; MEANINGFUL USE; SYSTEM;
D O I
10.1136/amiajnl-2013-001617
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The aim of this study was to assess the accuracy of clinician-entered data in imaging clinical decision support (CDS). We used CDS-guided CT angiography (CTA) for pulmonary embolus (PE) in the emergency department as a case example because it required clinician entry of D-dimer results which could be unambiguously compared with actual laboratory values. Of 1296 patients with CTA orders for suspected PE during 2011, 1175 (90.7%) had accurate D-dimer values entered. In 55 orders (4.2%), incorrectly entered data shielded clinicians from intrusive computer alerts, resulting in potential CTA overuse. Remaining data entry errors did not affect user workflow. We found no missed PEs in our cohort. The majority of data entered by clinicians into imaging CDS are accurate. A small proportion may be intentionally erroneous to avoid intrusive computer alerts. Quality improvement methods, including academic detailing and improved integration between electronic medical record and CDS to minimize redundant data entry, may be necessary to optimize adoption of evidence presented through CDS.
引用
收藏
页码:23 / 26
页数:4
相关论文
共 12 条
[1]  
[Anonymous], FED REG
[2]   Ten commandments for effective clinical decision support: Making the practice of evidence-based medicine a reality [J].
Bates, DW ;
Kuperman, GJ ;
Wang, S ;
Gandhi, T ;
Kittler, A ;
Volk, L ;
Spurr, C ;
Khorasani, R ;
Tanasijevic, M ;
Middleton, B .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2003, 10 (06) :523-530
[3]   Launching HITECH [J].
Blumenthal, David .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (05) :382-385
[4]   Exclusion of patients from pay-for-performance targets by english physicians [J].
Doran, Tim ;
Fullwood, Catherine ;
Reeves, David ;
Gravelle, Hugh ;
Roland, Martin .
NEW ENGLAND JOURNAL OF MEDICINE, 2008, 359 (03) :274-284
[5]   Adoption and Meaningful Use of Computerized Physician Order Entry With an Integrated Clinical Decision Support System for Radiology: Ten-Year Analysis in an Urban Teaching Hospital [J].
Ip, Ivan K. ;
Schneider, Louise I. ;
Hanson, Richard ;
Marchello, Dana ;
Hultman, Patricia ;
Viera, Michael ;
Chiang, Brian ;
Andriole, Katherine P. ;
Menard, Andrew ;
Schade, Susan ;
Seltzer, Steven E. ;
Khorasani, Ramin .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2012, 9 (02) :129-136
[6]   Meaningful Use of Electronic Health Records The Road Ahead [J].
Jha, Ashish K. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2010, 304 (15) :1709-1710
[7]   Frequency of Inappropriate Medical Exceptions to Quality Measures [J].
Persell, Stephen D. ;
Dolan, Nancy C. ;
Friesema, Elisha M. ;
Thompson, Jason A. ;
Kaiser, Darren ;
Baker, David W. .
ANNALS OF INTERNAL MEDICINE, 2010, 152 (04) :225-U49
[8]   Effect of Computerized Clinical Decision Support on the Use and Yield of CT Pulmonary Angiography in the Emergency Department [J].
Raja, Ali S. ;
Ip, Ivan K. ;
Prevedello, Luciano M. ;
Sodickson, Aaron D. ;
Farkas, Cameron ;
Zane, Richard D. ;
Hanson, Richard ;
Goldhaber, Samuel Z. ;
Gill, Ritu R. ;
Khorasani, Ramin .
RADIOLOGY, 2012, 262 (02) :468-474
[9]   Decreasing Use of High-Cost Imaging: The Danger of Utilization-Based Performance Measures [J].
Raja, All S. ;
Walls, Ron M. ;
Schuur, Jeremiah D. .
ANNALS OF EMERGENCY MEDICINE, 2010, 56 (06) :597-599
[10]   Spiral computed tomography for acute pulmonary embolism [J].
Schoepf, UJ ;
Goldhaber, SZ ;
Costello, P .
CIRCULATION, 2004, 109 (18) :2160-2167