Virtual-Switching-Aware VM Consolidation in Virtualized Data Centers

被引:1
作者
Li, Mingfu [1 ]
Bi, Jingping [1 ]
Li, Zhongcheng [1 ]
机构
[1] Chinese Acad Sci, Inst Comp Technol, Beijing, Peoples R China
来源
2014 IEEE 6TH INTERNATIONAL CONFERENCE ON CLOUD COMPUTING TECHNOLOGY AND SCIENCE (CLOUDCOM) | 2014年
基金
中国国家自然科学基金;
关键词
VM consolidation; virtual switching; server capacity violation probability;
D O I
10.1109/CloudCom.2014.49
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In virtualized data centers, live virtual machine (VM) migration can increase energy efficiency by consolidating VMs on fewer servers. This problem is usually considered as Bin Packing Problem with the server capacity constraints, such as CPU, memory and network bandwidth. In order to minimize the communication traffic in data center network, existing works proposed correlation-aware VM consolidation algorithms. VMs with high inter traffic will be consolidated as close as possible (e.g. within a physical server). However, the traffic load of virtual switches causes a certain number of CPU cycles of physical servers to move traffic through virtual switches. This increases the risk that VMs running on servers are not allocated enough resource, and consequently reduces VMs' performance. In this work, we conduct experiments to estimate the server CPU overhead caused by virtual switching, and based on the experiment results, we propose virtual-switching-aware VM consolidation algorithm to solve this problem. Experiments on representative data center workloads show that the overhead can occupy 10% to 30% of server's CPU resources. Besides, our algorithm has a sharp decrease of the server capacity violation probability compared with the state-of-the-art baseline.
引用
收藏
页码:817 / 822
页数:6
相关论文
共 19 条
[1]  
Ahmad F., 2012, TECHNICAL REPORT
[2]  
[Anonymous], 2012, ISTCCCTR12101
[3]  
[Anonymous], 2009, P WORKSH HOT TOP NET
[4]  
Benson Theophilus, 2010, Computer Communication Review, V40, P92, DOI 10.1145/1592681.1592692
[5]  
Biran O., 2012, Proceedings of the 2012 12th IEEE/ACM International Symposium on Cluster, Cloud and Grid Computing (CCGrid 2012), P498, DOI 10.1109/CCGrid.2012.119
[6]  
Bolei Zhang, 2012, 2012 Sixth International Conference on Innovative Mobile and Internet Services in Ubiquitous Computing (IMIS 2012), P280, DOI 10.1109/IMIS.2012.71
[7]  
Dias D. S., 2012, 2012 GLOBAL INFORM I, P1, DOI 10.1109/GIIS.2012.6466665
[8]   VL2: A Scalable and Flexible Data Center Network [J].
Greenberg, Albert ;
Hamilton, James R. ;
Jain, Navendu ;
Kandula, Srikanth ;
Kim, Changhoon ;
Lahiri, Parantap ;
Maltz, David A. ;
Patel, Parveen ;
Sengupta, Sudipta .
COMMUNICATIONS OF THE ACM, 2011, 54 (03) :95-104
[9]   The Cost of a Cloud: Research Problems in Data Center Networks [J].
Greenberg, Albert ;
Hamilton, James ;
Maltz, David A. ;
Patel, Parveen .
ACM SIGCOMM COMPUTER COMMUNICATION REVIEW, 2009, 39 (01) :68-73
[10]  
Hao Jin, 2012, GLOBECOM 2012 - 2012 IEEE Global Communications Conference, P2505, DOI 10.1109/GLOCOM.2012.6503493