Quantification of atherosclerosis with MRI and image processing in spontaneously hyperlipidemic rabbits

被引:4
作者
Hänni, M [1 ]
Edvardsson, H [1 ]
Wågberg, M [1 ]
Pettersson, K [1 ]
Smedby, Ö [1 ]
机构
[1] Univ Uppsala Hosp, Dept Radiol, SE-75185 Uppsala, Sweden
关键词
atherosclerosis; quantification; magnetic resonance; image processing; animal model;
D O I
10.1081/JCMR-120038087
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The need for a quantitative method to assess atherosclerosis in vivo is well known. This study tested, in a familiar animal model of atherosclerosis, a combination of magnetic resonance imaging (MRI) and image processing. Six spontaneously hyperlipidemic (Watanabe) rabbits were examined with a knee coil in a 1.5-T clinical MRI scanner. Inflow angio (2DI) and proton density weighted (PDW) images were acquired to examine 10 cm of the aorta immediately cranial to the aortic bifurcation. Examination of the thoracic aorta was added in four animals. To identify the inner and outer boundary of the arterial wall, a dynamic contour algorithm (Gradient Vector Flow snakes) was applied to the 2DI and PDW images, respectively, after which the vessel wall area was calculated. The results were compared with histopathological measurements of intima and intima-media cross-sectional area. The correlation coefficient between wall area measurements with MRI snakes and intima-media area was 0.879 when computed individual-wise for abdominal aortas, 0.958 for thoracic aortas, and 0.834 when computed segment-wise. When the algorithm was applied to the PDW images only, somewhat lower correlations were obtained. The MRI yielded significantly higher values than histopathology, which excludes the adventitia. Magnetic resonance imaging, in combination with dynamic contours, may be a suitable technique for quantitative assessment of atherosclerosis in vivo. Using two sequences for the measurement seems to be superior to using a single sequence.
引用
收藏
页码:675 / 684
页数:10
相关论文
共 22 条
  • [1] Effects of lipid-lowering by simvastatin on human atherosclerotic lesions - A longitudinal study by high-resolution, noninvasive magnetic resonance imaging
    Corti, R
    Fayad, ZA
    Fuster, V
    Worthley, SG
    Helft, G
    Chesebro, J
    Mercuri, M
    Badimon, JJ
    [J]. CIRCULATION, 2001, 104 (03) : 249 - 252
  • [2] Noninvasive in vivo high-resolution magnetic resonance imaging of atherosclerotic lesions in genetically engineered mice
    Fayad, ZA
    Fallon, JT
    Shinnar, M
    Wehrli, S
    Dansky, HM
    Poon, M
    Badimon, JJ
    Charlton, SA
    Fisher, EA
    Breslow, JL
    Fuster, V
    [J]. CIRCULATION, 1998, 98 (15) : 1541 - 1547
  • [3] COMPENSATORY ENLARGEMENT OF HUMAN ATHEROSCLEROTIC CORONARY-ARTERIES
    GLAGOV, S
    WEISENBERG, E
    ZARINS, CK
    STANKUNAVICIUS, R
    KOLETTIS, GJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1987, 316 (22) : 1371 - 1375
  • [4] Quantitation of atherosclerosis by magnetic resonance imaging and 3-D morphology operators
    Hänni, M
    Lekka-Banos, I
    Nilsson, S
    Häggroth, L
    Smedby, Ö
    [J]. MAGNETIC RESONANCE IMAGING, 1999, 17 (04) : 585 - 591
  • [5] ATHEROSCLEROSIS IN WATANABE HERITABLE HYPERLIPEMIC RABBITS - EVALUATION BY MACROSCOPIC, MICROSCOPIC AND BIOCHEMICAL METHODS AND COMPARISON OF ATHEROSCLEROSIS VARIABLES
    HANSEN, BF
    MORTENSEN, A
    HANSEN, JF
    IBSEN, P
    FRANDSEN, H
    NORDESTGAARD, BG
    [J]. APMIS, 1994, 102 (03) : 177 - 190
  • [6] Atherosclerotic aortic component quantification by noninvasive magnetic resonance imaging: An in vivo study in rabbits
    Helft, G
    Worthley, SG
    Fuster, V
    Zaman, AG
    Schechter, C
    Osende, JI
    Rodriguez, OJ
    Fayad, ZA
    Fallon, JT
    Badimon, JJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (04) : 1149 - 1154
  • [7] Kang XJ, 2000, MAGNET RESON MED, V44, P968, DOI 10.1002/1522-2594(200012)44:6<968::AID-MRM20>3.0.CO
  • [8] 2-I
  • [9] SNAKES - ACTIVE CONTOUR MODELS
    KASS, M
    WITKIN, A
    TERZOPOULOS, D
    [J]. INTERNATIONAL JOURNAL OF COMPUTER VISION, 1987, 1 (04) : 321 - 331
  • [10] A semi-automatic technique for measurement of arterial wall from black blood MRI
    Ladak, HM
    Thomas, JB
    Mitchell, JR
    Rutt, BK
    Steinman, DA
    [J]. MEDICAL PHYSICS, 2001, 28 (06) : 1098 - 1107