Comparative analysis of multi-criteria decision making methods for the assessment of optimal SVC location

被引:15
作者
Aydin, Faruk [1 ]
Gumus, Bilal [2 ]
机构
[1] Marmara Univ, Fac Technol, Dept Elect & Elect Engn, TR-34722 Istanbul, Turkey
[2] Dicle Univ, Fac Engn, Dept Elect & Elect Engn, TR-21680 Diyarbakir, Turkey
关键词
Borda count method; FACTS; MCDM; optimal location; PSAT; voltage stability; CONTINUATION POWER-FLOW; OPTIMAL PLACEMENT; MCDM METHODS; SYSTEM; OPTIMIZATION; TECHNOLOGIES; PARAMETERS; SELECTION; GIS;
D O I
10.24425/bpasts.2022.140555
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The goal of multi-criteria decision making (MCDM) is to select the most appropriate of the alternatives by evaluating many conflicting criteria together. MCDM methods are widely available in the literature and have been used in various energy problems. The key problems studied in electrical power systems in recent years have included voltage instability and voltage collapse. Different flexible alternating current transmission systems (FACTS) equipment has been used for this purpose for decades, increasing voltage stability while enhancing system efficiency, reliability and quality of supply, and offering environmental benefits. Finding the best locations for these devices in terms of voltage stability in actual electrical networks poses a serious problem. Many criteria should be considered when determining the most suitable location for the controller. The aim of this paper is to provide a comparative analysis of MCDM techniques to be used for optimal location of a static VAR compensator (SVC) device in terms of voltage stability. The ideal location can be determined by means of sorting according to priority criteria. The proposed approach was carried out using the Power System Analysis Toolbox (PSAT) in MATLAB in the IEEE 14-bus test system. Using ten different MCDM methods, the most appropriate locations were compared among themselves and a single ranking list was obtained, integrated with the Borda count method, which is a data fusion technique. The application results showed that the methods used are consistent among themselves. It was revealed that the integrated model was an appropriate method that could be used for optimal location selection, providing reliable and satisfactory results to power system planners.
引用
收藏
页数:11
相关论文
共 54 条
[1]   THE CONTINUATION POWER FLOW - A TOOL FOR STEADY-STATE VOLTAGE STABILITY ANALYSIS [J].
AJJARAPU, V ;
CHRISTY, C .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1992, 7 (01) :416-423
[2]   Optimum network reconfiguration based on maximization of system loadability using continuation power flow theorem [J].
Aman, M. M. ;
Jasmon, G. B. ;
Bakar, A. H. A. ;
Mokhlis, H. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 54 :123-133
[3]  
Amrane Y., 2020, PREDICTIVE MODELLING, V1st, P1, DOI [10.1016/B978-0-12-817772-3.00001-X, DOI 10.1016/B978-0-12-817772-3.00001-X]
[4]   Using AHP and Dempster-Shafer theory for evaluating sustainable transport solutions [J].
Awasthi, Anjali ;
Chauhan, Satyaveer S. .
ENVIRONMENTAL MODELLING & SOFTWARE, 2011, 26 (06) :787-796
[5]  
Aycin E, 2020, MULTICRITERIA DECISI, P4
[6]   Determining Optimal SVC Location for Voltage Stability Using Multi-Criteria Decision Making Based Solution: Analytic Hierarchy Process (AHP) Approach [J].
Aydin, Faruk ;
Gumus, Bilal .
IEEE ACCESS, 2021, 9 :143166-143180
[7]  
Bakar S., 2019, ASM Science Journal, V12, P53
[8]   Multi-criteria ranking of energy generation scenarios with Monte Carlo simulation [J].
Balezentis, Tomas ;
Streimikiene, Dalia .
APPLIED ENERGY, 2017, 185 :862-871
[9]  
Boudour M., 2008, RENEWABLE ENERGIES P, V1, P175, DOI [10.24084/repqj06.256, DOI 10.24084/REPQJ06.256]
[10]  
Brauers WKM, 2006, CONTROL CYBERN, V35, P445