Arterial occlusions increase the risk of in-stent restenosis after vertebral artery ostium stenting

被引:20
|
作者
Li, Jingzhi [1 ,2 ]
Hua, Yang [1 ]
Needleman, Laurence [2 ]
Forsberg, Flemming [2 ]
Eisenbray, John R. [2 ]
Li, Zhaojun [3 ]
Liu, Ran [1 ]
Tian, Xiaojie [1 ]
Jiao, Liqun [4 ]
Liu, Ji-Bin [2 ]
机构
[1] Capital Med Univ, Xuanwu Hosp, Dept Vasc Ultrasonog, Beijing, Peoples R China
[2] Thomas Jefferson Univ, Dept Radiol, Philadelphia, PA 19107 USA
[3] Shanghai Jiao Tong Univ, Sch Med, Shanghai Gen Hosp, Dept Ultrasound, Shanghai, Peoples R China
[4] Capital Med Univ, Xuanwu Hosp, Dept Neurosurg, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
DRUG-ELUTING STENTS; BARE METAL STENTS; ULTRASOUND; DISEASE; STENOSIS; STROKE; CIRCLE;
D O I
10.1136/neurintsurg-2018-014243
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Objective The study was designed to investigate if vascular occlusion in the internal carotid artery (ICA) or the contralateral vertebral artery (VA) contribute to developing in-stent restenosis (ISR) in patients with vertebral artery ostium stenosis (VAOS). Methods 420 consecutive patients treated with VAOS stents (from a population of 8145 patients with VAOS) from January 2013 to December 2014 were analyzed in this retrospective study; 216 with drug eluted stents and 204 with bare metal stents. Based on pre-stent DSA findings, patients were divided into four groups: both carotid and vertebral arteries patent (PAT), ICA occlusion (ICA-OCC), contralateral VA occlusion (CVA-OCC), and combined occlusions (C-OCC). The incidence of ISR (stenosis > 50%) was compared between groups using Cox regression analysis. Results Of the 420 patients, the mean incidence of ISR was 36.4%, with a median 12 months of follow-up (IQR 3-12). Logistic regression analysis showed that drug eluting stent had less ISR than bare metal stent (OR=0.38, 95% CI 0.19 to 0.75, P=0.01). Cox regression analysis showed that CVA-OCC (HR=1.63, P=0.02) and C-OCC (HR=3.30, P=0.001) were risk factors for ISR but not ICA-OCC (P=0.31). In the CVA-OCC and C-OCC groups, in-stent peak systolic velocity (PSV) =140 cm/s, 1 day after successful stenting, was associated with subsequent development of ISR (OR=2.81, 95% CI 1.06 to 7.43, P=0.04). Conclusion C ontralateral VA occlusion at the time of stenting increased the risk of ISR, especially if stent PSV on day 1 was > 140 cm/s. Bare metal stents had more ISR than drug eluting stents.
引用
收藏
页码:574 / 578
页数:5
相关论文
共 50 条
  • [1] Effects of the Vertebral Artery Ostium/Subclavian Artery Angle on In-Stent Restenosis after Vertebral Artery Ostium Stenting
    Su, Hui
    Yu, Shengyuan
    Tian, Chenglin
    Du, Zhihua
    Liu, Xinfeng
    Wang, Jun
    Cao, Xiangyu
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [2] Incidence and Predictors of the In-stent Restenosis after Vertebral Artery Ostium Stenting
    Chen, Wanhong
    Huang, Fang
    Li, Min
    Jiang, Yongjun
    He, Jianbo
    Li, Huiqi
    Dai, Zheng
    Shi, Wei
    Zhu, Mingyue
    Chen, Guanghui
    Yang, Fang
    Zhang, Renliang
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2018, 27 (11) : 3030 - 3035
  • [3] In-stent restenosis after vertebral artery stenting
    Jiang, Yongjun
    Xu, Xiaomeng
    Wen, Zhuoyu
    Xu, Xiaohui
    Yang, Lian
    Liu, Xinfeng
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 187 : 430 - 433
  • [4] Long-Term Risk of In-Stent Restenosis and Stent Fracture for Extracranial Vertebral Artery Stenting
    Li, Man Kwun Andrew
    Tsang, Anderson Chun On
    Tsang, Frederick Chun Pong
    Ho, Wai Shing
    Lee, Raymand
    Leung, Gilberto Ka Kit
    Lui, Wai Man
    CLINICAL NEURORADIOLOGY, 2019, 29 (04) : 701 - 706
  • [5] In-stent restenosis after vertebral artery origin stenosis stenting: a nomogram for risk assessment
    Yang, Kun
    Fang, Shiyuan
    Zhang, Xiao
    Wang, Tao
    Feng, Yiding
    Jiao, Liqun
    Yan, Yuxiang
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2023, 15 (E1) : E41 - E45
  • [6] Influence of Vessel Size and Tortuosity on In-stent Restenosis After Stent Implantation in the Vertebral Artery Ostium
    Zhou, Zhiming
    Yin, Qin
    Xu, Gelin
    Yue, Xuanye
    Zhang, Renliang
    Zhu, Wusheng
    Fan, Xiaobing
    Ma, Minmin
    Liu, Xinfeng
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 (03) : 481 - 487
  • [7] Influence of Vessel Size and Tortuosity on In-stent Restenosis After Stent Implantation in the Vertebral Artery Ostium
    Zhiming Zhou
    Qin Yin
    Gelin Xu
    Xuanye Yue
    Renliang Zhang
    Wusheng Zhu
    Xiaobing Fan
    Minmin Ma
    Xinfeng Liu
    CardioVascular and Interventional Radiology, 2011, 34 : 481 - 487
  • [8] Long-Term Risk of In-Stent Restenosis and Stent Fracture for Extracranial Vertebral Artery Stenting
    Man Kwun Andrew Li
    Anderson Chun On Tsang
    Frederick Chun Pong Tsang
    Wai Shing Ho
    Raymand Lee
    Gilberto Ka Kit Leung
    Wai Man Lui
    Clinical Neuroradiology, 2019, 29 : 701 - 706
  • [9] The Incidence and Risk Factors of In-Stent Restenosis for Vertebrobasilar Artery Stenting
    Dai Zheng
    Zhu Mingyue
    Shi Wei
    Li Min
    Chen Wanhong
    Dai Qiliang
    Jiang Yongjun
    Liu Xinfeng
    WORLD NEUROSURGERY, 2018, 110 : E937 - E941
  • [10] Overlap stenting for in-stent restenosis after carotid artery stenting
    Nishihori, Masahiro
    Ohshima, Tomotaka
    Yamamoto, Taiki
    Goto, Shunsaku
    Nishizawa, Toshihisa
    Shimato, Shinji
    Izumi, Takashi
    Kato, Kyozo
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2016, 78 (02): : 143 - 149